In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Any
repairs must be carried out by specialised personnel using original and certified materials.
The appliance is not to be used by children or people with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction.
Do not touch the card for adjustments and/or maintenance.
NOTE:
The restorable fuse intervenes in case of anomalous operating conditions, breaking the circuit. It is automatically
restored with normal operating conditions so that the card goes back to its correct operation.
If the fuse is not restored automatically, carefully check the devices externally connected to the card.
WARNINGS FOR THE USER
ELECTRICAL CONNECTIONS: FASTONS
PROTECTION FUSES
SETTINGS - dip switch dip1
Terminal
M1
M2
M3
1
4
9
2
5
6
10
L/S
L230
S12/24
L12/24
+ 12/24
LUX
START
COM
- 12/24
NO
V_AUX
V_AUX
COM
NC
Common flashing light/electrical lock
12/24 V power supply card input
NO Contact
230 V flashing light input
Photoresistance input
START input
Common START and LUX
230 V or 12/24 V input for courtesy light or electromagnet
power supply
230 V or 12/24 V input for courtesy light or electromagnet
power supply
Flashing light or 12/24 electrical lock input
12/24 V power supply card input
NC Contact
Common Contacts
3
7
8
11
12
13
Position
Signal
Description
Position
Dip
RT1
DIP1
DIP2
250 mA
ON
ON
OFF
OFF
RESTORABLE
12 Vac/dc
24 Vac/dc
START
START
Card power supply input protection
Power supply input preset for 12 V
Power supply input preset for 24 V
Bistable START command
Monostable START command
Value
Status
Type
Function
Description
Description
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
For people's safety, it is important to follow these instructions.
Please keep this manual.
CL100
12
UK
Содержание GI.BI.DI. CL100
Страница 58: ...NOTE CL100 58 ...