background image

CONFIGURATION JUMPER 

SW11

SW12

Configuration

Configuration

Functioning 

mode

Functioning 

mode

Description

Description

OPEN

OPEN

C - B

A - C

A - C

HCS ROLLING

NORMAL

HCS FIX

DIP SWITCH

AUA

Standard rolling code functioning with variable code

Standard functioning

Rolling code functioning with fixed code manageable with PRG_01 Consolle 

Fixed code functioning with dip switch

A  transmitter  set  by  means  of  the  PRG_01  programmer  as  another  one  is 
automatically  memorized  in  the  event  of  continuous  transmission  for  5  s  (HCS 
ROLLING)

TIMES LEARNING PROCEDURE

1. When the door is closet, place the DIP n°1 (DIP SWITCH DIP1) on ON. The green led DL4 flashes fast. 

In this phase, if the DIP n°1 is put on OFF  you leave the procedure, the memorized data remain stored and the 
next START command will cause the opening.

2. START 

The motor moves in opening. The green led DL4 keeps on flashing fast. The DIP n° 1 becomes 

uninfluential.

3. START 

The motor stops in opening and the green led DL4 switches on fixed. The control unit waits for 
commands.

If in this phase the DIP n°1 is put on OFF, you leave the procedure, only saving the work time and disabling the 
automatic closing. The green led DL4 switches off and the next START command will cause the closing.

4. START 

The pause time counting starts. The green led DL4 flashes slowly.

In this phase, if the DIP n°1 is put on OFF, you leave the procedure, only saving the work time and disabling the 
automatic closing. The green led DL4 switches off and the next START command will cause the closing.

5. START 

 It ends the pause time counting, the work time and the pause time are memorized. The green 

led DL4 

remains on fixed.

6. To  leave  the  times  learning  procedure,  put  the  DIP  n°  1  on  OFF  and  the  next  START  command  or 

GENERAL_CLOSE will cause the closing. 

To modify the memorized times, it is necessary to repeat the above procedure.

WARNING

During the times learning phase, the PHOTO, SAF, GENERAL_OPEN, GENERAL_CLOSE are disabled.

If the radio command is used as START, pay attention to the correct configuration of the dip n. 5 – 6 – 7 – 8.

DEFAULT VALUES

Work time: 30 s 

Automatic closing disabled.

SR100

14

UK

Содержание GBD SR100

Страница 1: ...I UK F E D P NL GR Centralina di controllo ISTRUZIONI PER L INSTALLAZIONE Control unit INSTRUCTIONS FOR INSTALLATIONS SR100 AS05190 SR100...

Страница 2: ...ponentes de pl stico y llevar los componentes electr nicos a los centros de recogida correspondientesevitandodeestamaneralacontaminaci nambientalconsustanciasperjudiciales ENTSORGUNG GI BI DI empfiehl...

Страница 3: ...2 RL1 RL2 DIP1 DIP2 START DL5 DL4 DL8 LEARN J3 DL1 DL2 DL3 DL6 5 6 7 8 9 1 2 3 4 M1 M2 M3 M4 A C B EARTH NEUTRAL 230 Vac PHASE 230 Vac 230Vac 40W MAX LAMP LAMP MOTOR OPEN MOTOR CLOSE MOTOR COM M PHOTO...

Страница 4: ...tions referring to the following tables and to the attached screen print Be extremely careful to connect in series all the devices that must be connected to the same N C normally closed input and in p...

Страница 5: ...nector for connexion to the programmer PRG_01 Input ANTENNA BRAID M4 J3 17 ANT 18 ANT In the event of an operating fault or failure cut the power upstream of the control unit and call Technical Servic...

Страница 6: ...IP6and7but the continuous pressure for 3 s on the channel 1 of the transmitter manages the openingofALLthecontrolunitsonwhichthetransmitterismemorized the continuous pressure for 3 s on the channel 3...

Страница 7: ...ention door closed the control unit does not open in opening stop and motion inversion for 2 s at next start pulse the motion starts in the obstacle freeing direction in pause it does not allow closin...

Страница 8: ...PECIFICATIONS Radioreceiver433 92MHz Memorizablecodesmax200 CODESLEARNING PresstheLEARNkey theDL8ledswitcheson itremainsonfor6s thenitswitchesoff Press the key selected with the dip n 6 7 of the trans...

Страница 9: ...or stops in opening and the green led DL4 switches on fixed The control unit waits for commands If in this phase the DIP n 1 is put on OFF you leave the procedure only saving the work time and disabli...

Страница 10: ...CTRONIC CONTROL UNIT SR100 are in conformity with the following CEE Directives EMC Directive 2004 108 CE and subsequent amendments and that the following harmonised standards have been applied EN60335...

Страница 11: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC6442 02 2009 Re...

Отзывы: