CONFIGURATION JUMPER
SW11
SW12
Configuration
Configuration
Functioning
mode
Functioning
mode
Description
Description
OPEN
OPEN
C - B
A - C
A - C
HCS ROLLING
NORMAL
HCS FIX
DIP SWITCH
AUA
Standard rolling code functioning with variable code
Standard functioning
Rolling code functioning with fixed code manageable with PRG_01 Consolle
Fixed code functioning with dip switch
A transmitter set by means of the PRG_01 programmer as another one is
automatically memorized in the event of continuous transmission for 5 s (HCS
ROLLING)
TIMES LEARNING PROCEDURE
1. When the door is closet, place the DIP n°1 (DIP SWITCH DIP1) on ON. The green led DL4 flashes fast.
In this phase, if the DIP n°1 is put on OFF you leave the procedure, the memorized data remain stored and the
next START command will cause the opening.
2. START
→
The motor moves in opening. The green led DL4 keeps on flashing fast. The DIP n° 1 becomes
uninfluential.
3. START
→
The motor stops in opening and the green led DL4 switches on fixed. The control unit waits for
commands.
If in this phase the DIP n°1 is put on OFF, you leave the procedure, only saving the work time and disabling the
automatic closing. The green led DL4 switches off and the next START command will cause the closing.
4. START
→
The pause time counting starts. The green led DL4 flashes slowly.
In this phase, if the DIP n°1 is put on OFF, you leave the procedure, only saving the work time and disabling the
automatic closing. The green led DL4 switches off and the next START command will cause the closing.
5. START
→
It ends the pause time counting, the work time and the pause time are memorized. The green
led DL4
remains on fixed.
6. To leave the times learning procedure, put the DIP n° 1 on OFF and the next START command or
GENERAL_CLOSE will cause the closing.
To modify the memorized times, it is necessary to repeat the above procedure.
WARNING
During the times learning phase, the PHOTO, SAF, GENERAL_OPEN, GENERAL_CLOSE are disabled.
If the radio command is used as START, pay attention to the correct configuration of the dip n. 5 – 6 – 7 – 8.
DEFAULT VALUES
Work time: 30 s
Automatic closing disabled.
SR100
14
UK