background image

BA24

LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA DI PROCEDERE ALL’INSTALLAZIONE.

• Questo prodotto è stato collaudato in GI.BI.DI. verificando la perfetta corrispondenza delle caratteristiche  

alle direttive vigenti.

• La GI.BI.DI. S.r.l. si riserva la facoltà di modificare i dati tecnici senza avviso, in funzione  dell'evoluzione 

del prodotto.

• This product has been tested in Gi.Bi.Di. verifying the perfect correspondence of the characteristics to the 

current directive.

• Gi.Bi.Di. S.r.l. reserves the right to modify the technical data without prior notice depending on the product 

development.

PLEASE READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION.

• Ce produit a été essayé en Gi.Bi.Di. en vérifiant la correspondance parfaite des caractéristiques aux 

règles en vigueur.

• Gi.Bi.Di.  S.r.l.  se  réserve  la  faculté  de  modifier  les  données  techniques  sans  aucun  préavis  suivant 

l’évolution de ses produits.

S’IL VOUS PLAÎT DE LIRE AVEC ATTENTION CETTE MANUAL AVANT DE PROCÉDER AVEC L’INSTALATION.

• Este  producto  ha  sido  probado  en  Gi.Bi.Di.  averiguando  la  perfecta  correspondencia  de  las 

características a las normas vigentes.

• La empresa Gi.Bi.Di. S.r.l. se reserva el derecho de modificar los datos técnicos sin previo aviso, en 

función de la evolución del producto.

POR FAVOR LEER CON ATENCIÓN ESTE MANUAL ANTES DE PROCEDER CON LA INSTALACIÓN.

• Dieses Produkt wurde in Gi.Bi.Di. geprüft um die perfekte Entsprechung der merkmäle an die geltende 

vorschriften zu prüfen.

• Gi.Bi.Di. S.r.l. behält sich das recht vor, die technischen daten der produktentwicklung entsprechend ohne 

voranzeige abzuändern.

BITTE LESEN SIE VORSICHTIG DIESEN MANUAL BEVOR MIT DER ANGLAGE VORZUGEHEN. 

I

UK

F

E

D

• Este  produto  foi  testado  em  Gi.Bi.Di.  verificando  a  correspondência  perfeita  das  características  ao 

normas vigentes.

• A Gi.Bi.Di. S.r.l. reserva-se o direito de modificar os dados técnicos sem pré-aviso em função de evolução 

do produto.

LER COM ATENÇÃO ESTE MANUAL ANTES DE PROCEDER COM A INSTALAÇÃO.

P

• Dit product werd gekeurd in Gi.Bi.Di. Er werd nauwlettend gecontroleerd of de kenmerken van het product 

perfect overeenkomen met de geldige richtlijnen.

• Gi.Bi.Di. S.r.l. behoudt zich het recht voor de technische gegevens te wijzigen zonder waarschuwing 

vooraf, als dat nodig is voor de evolutie van het product.

LEES DEZE GEBRUIKSAANWIJZING ZEER AANDACHTIG ALVORENS DE INSTALLATIE AAN TE VATTEN.

NL

• Η  εταιρία  GI.BI.DI.  S.r.l.  έχει  ελέγξει  αυτό  το  προιόν  όσον  αφορά  την  τέλεια  προσαρμογή  των 

χαρακτηριστικών του στην ισχύουσα νομοθεσία.

• Η εταιρία Gi.Bi.Di. S.r.l διατηρεί το δικαίωμα αλλαγής των τεχνικών προδιαγραφών χωρίς

προειδοποίηση, όσον αφορά ανάπτυξη των προιόντων της.

LEES DEZE GEBRUIKSAANWIJZING ZEER AANDACHTIG ALVORENS DE INSTALLATIE AAN TE VATTEN.

GR

Содержание G:B:D: AS05100

Страница 1: ...BA24 I UK F E D P NL BA24 AS05100 Apparecchiatura elettronica ISTRUZIONI PER L INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS GR...

Страница 2: ...l se reserva el derecho de modificar los datos t cnicos sin previo aviso en funci ndelaevoluci ndelproducto POR FAVOR LEER CON ATENCI N ESTE MANUAL ANTES DE PROCEDER CON LA INSTALACI N Dieses Produkt...

Страница 3: ...OPEN JP4 COM EL EL1 EL2 GND SPIA 24Vcc SEC JP5 JP2 RL1 RL2 RL3 RL5 RL4 RL6 RL7 RL8 RL9 F1 F3 BA24 D1 CF1 CF2 F2 LED STATUS ON OFF AC AC SK SK AS05020 CB24 230Vac 24Vac 24Vac PHOTO 1 COSTA PED NO FCA M...

Страница 4: ...ter intervention of the safety devices At the next Start pulse the motion restarts in the obstacle freeing direction SEPARATE SAFETY DEVICES POWER SUPPLY Connect the safety devices that must be tested...

Страница 5: ...ging away from children since they pose a potential risk The manufacturer declines all responsibility for improper functioning of the automated device if the original components and accessories suitab...

Страница 6: ...l Service Periodically check functioning of the safety devices Any repairs must be carried out by specialised personnel using original and certified materials The appliance is not to be used by childr...

Страница 7: ...ease the gate will start openingwithoutfurthercommands Ifinterceptedduringpause itreloadsthepausetime PHOTOCELL 1 input N C If not used disable during programming Operation Input active only during cl...

Страница 8: ...inthepicture Press simultaneously the keys ESC and OK for 3 seconds ThewritingGbdwillturnoff ESC OK Gbd 2 The writing P A S S appears on the display Press the OK button to go to step 3 Press the ESC b...

Страница 9: ...eytoconfirmand gotostep7 ESC OK 4 6 8 0 6 Now the installer code is complete go to step 8 If the installer code is not correct go back to step 2 ESC OK 4 6 8 3 7 The 5 main menus appear on the display...

Страница 10: ...F H E 11 Use the and keys to select the submenus C1 C2 C3 C4 Press the OK button in sequence to enable the input the Y will appear next to C1 disable the input the N will appear next to C1 ESC OK C 1...

Страница 11: ...digit Confirm with the OK button and go to step 17 ESC OK 0 1 0 0 16 The third digit blinks Use the or buttons to modify the value of this digit Confirm with the OK button and go to step 18 ESC OK 0...

Страница 12: ...eyinsequenceto enabletheinput theYwillappearnexttoE2 disabletheinput theNwillappearnexttoE2 Usethe and keystoenterthefollowingorthepreviousmenu Use the ESC key to exit the menu ACFHE is now shown on t...

Страница 13: ...setting the outputs for the electrical lock 2 can be used for a 3 minutes timed courtesy light 24V max 10W The activation of this menu automatically disables A5 1 MOTOR CONFIGURATION A4 Y MENU A SYST...

Страница 14: ...t automatically closes the gate If the gate is open Start closes the gate Pedestrian is uninfluential during opening It will be active in pause if the pedestrian automatic closing is disabled In closi...

Страница 15: ...following menu C1 C2 C3 KEY enters the previous menu C3 C2 C1 KEY ESC leaves the menu KEY OK activates Y yes disactivates N the function Enables total automatic closing H9 Enables pedestrian automatic...

Страница 16: ...ith3longflashes 2sec PHASE 3 if the edge 8K2 is enabled when the Start or the Pedestrian command is given the COSTA Input is tested value 8K2 If the value isnotcorrect thefaultissignalledwith2longflas...

Страница 17: ...tsthemotion NOTE ENABLE THE ANTI CRUSHING ONLY IF ALSO THE LIMIT SWITCHESAREENABLED Y2 ENABLED LIMITSWITCHAMPEROMETRIC The amperometric stops themotion N COURTESY LIGHT WITH TWO MOTORS C11 Y Activethe...

Страница 18: ...or will automaticallycloseafterthepausetime Itisnotpossibletoactivatetheclosingwiththe start command WARNING remember to preset the automatic closing the activation of thismenuautomaticallydefuseC16 C...

Страница 19: ...0010 maximum force F6 MOTOR 2 DECELERATION SPEED Adjusts the thrust of motor 2 during deceleration phase 0001 minimum force 0010 maximum force F7 MOTOR 2 FORCE AMPEROMETRIC Adjusts the amperometric t...

Страница 20: ...er code it will be possible to delete the old one by pressing simultaneously the keys and for 3 seconds when the writingPASSappears In this way all the existing setting are erased and the default ones...

Страница 21: ...the menu C21 menu C21 blinking By pressing OK the times programming procedure starts menu C21 Y fixed then 1 motor configuration START the leaf starts opening When the leaf arrives at the desired open...

Страница 22: ...ues the decelerated motion for the time set in the menus H3 and H6 If using two limit switches the first one starts deceleration and the second one stops deceleration but does not lock the motion if T...

Страница 23: ...ashings Photo 1 test failed at opening Blocked open door 4 fast flashings Photo 1 test failed at closing Blocked closed door 4 slow flashings Amperometric circuit test failed at opening Blocked open d...

Страница 24: ...CRUSHING ENABLED C11 COURTESY LIGHT WITH 2 MOTORS DISABLED F2 Parameters type F F1 10 MOTOR 1 FORCE 05 MOTOR 1 DECELERATION F3 80 AMPEROMETRIC MOTOR 1 FORCE F4 50 AMPEROMETRIC MOTOR 1 DECELERATION Pa...

Страница 25: ...ts are on and the green LEDs of the normally open contacts are off Check that the writing SAF does not appear on the LCD intercepted or faulty edge Check that the relative LEDs turn off when limit swi...

Страница 26: ...enu C21 and select Y to activate automatic time programming then press START key see page 20 Time learning procedure Go to menu C5 to program slowdowns Go to menu C6 to choose the number of limit swit...

Страница 27: ...s ELECTRONIC CONTROL UNIT BA24 are in conformity with the following CEE Directives EMC Directive 2004 108 CE and subsequent amendments and that the following harmonised standards have been applied Dat...

Страница 28: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC4976 12 2008 Re...

Отзывы: