Description
Menu
Function
Status
Enables automatic closing. Also see menu H9.
AUTOMATIC
CLOSING
Disables automatic closing.
C1
C2
E
E
FAST CLOSING
C3
E
Disables the fast closing function.
E
C4
SAFETY DEVICE
TEST
C7
E
Disables the safety device test.
E
C8
LIMIT SWITCH
C9
E
Disables limit switch reading.
E
E
C10
Enables the deceleration function.
DECELERATIONS
Disables the deceleration function.
C11
C12
E
Enables the water hammer function.
Operation
: When the Start command is given, before starting the opening phase a
3-second closing pulse is given to aid release of the electric lock.
WATER HAMMER
C13
E
Disables the water hammer function.
E
C14
Enables the final closing stroke function
Operation
:
At the end of the run time during closing without deceleration, a 1-second pulse is
given at full power, irrespective of the force adjustment When deceleration is active,
the pulse is given at the end of the deceleration period.
FINAL CLOSING
STROKE
C15
E
Disables the final closing stroke function.
E
C16
Enables the hydraulic lock retention function.
Operation:
Only for hydraulic operators. If the gate has not performed any manoeuvres in
the last 4 hours, a 5-second closing pulse is given.
HYDRAULIC LOCK
RETENTION
C17
E
Disables the hydraulic lock retention function.
E
C18
Not implemented.
Not implemented.
C19
C20
-
-
Enables time programming in self-learning
Operation
: See “Time self-learning procedure".
AUTOMATIC
PROGRAMMING
C21
E
The operator is hydraulic.*
HYDRAULIC MOTOR
C22
E
E
C5
Enables 3-second pre-flashing for motor start.
E
E
PRE-FLASHING
C6
MENU C: FUNCTION SELECTION
Enables the fast closing function.
Operation
: Active only on photocell 1.
Reduces the pause time to 3 seconds following interception and subsequent
freeing of the photocells.
Disables pre-flashing The flashlight and the motors start at the same instant.
Enables the safety device test.
Operation
: When the Start or Pedestrian command is given, the flashlight starts and
at the same time the power to the safety devices is cut for 0.5 seconds and then
restored: if the inputs of the safety devices go back to N.C., the motors start,
otherwise a fault is signalled with 3 long flashes.
Enables limit switch reading. When the limit switches are activated, deceleration
(if activated) starts upon reaching the limit switches and continues for the time
H3 and H6. When the limit switches are activated and deceleration is
deactivated, the limit switches stop the motion.
C23
The operator is not hydraulic and it is advisable to program the decelarations.*
Enables the flashing light with fixed output.
WARNING: for the blinking function, it is necessary to connect a flashing light board
with blinking circuit.
FIXED FLASHING
LIGHT
C24
C25
E
E
Disables the flashing light with fixed output.
*
NOTE
: If motion is inverted from opening to closing and vice versa, the opening and closing times will be the same in the case of an
electromechanical configuration, but different in the case of a hydraulic configuration in order to take into account the different speed
at which the operator runs in the two phases. In some hydraulic applications where the operators run at the same speed during
opening and closing (e.g. FLOOR 810), it is advisable to enable electromechanical configuration.
MENU H: TIME ADJUSTMENT
Menu
Function
MOTOR 1 OPENING TIME
H1
Description
Gate 1 opening time.
Menu
Function
MENU F: FORCE AND SPEED ADJUSTMENTS
MOTOR 1 FORCE
F1
All the times can be set in steps of 1 second.
Description
Adjusts the thrust of motor 1.
0001 = minimum force
0010 = maximum force
NB. HYDRAULIC OPERATORS, SET MAXIMUM VALUE
DECELERATION
FORCE MOTOR 1
F2
Adjusts the thrust of motor 1 during deceleration
0001 = minimum force
0010 = maximum force
MOTOR 2 FORCE
F3
Adjusts the thrust of motor 2.
0001 = minimum force
0010 = maximum force
NB. HYDRAULIC OPERATORS, SET MAXIMUM VALUE
DECELERATION
FORCE MOTOR 2
F4
Adjusts the thrust of motor 2 during deceleration
0001 = minimum force
0010 = maximum force
MOTOR 1 CLOSING TIME
H2
Gate 1 closing time.
MOTOR 1 DECELERATION TIME
H3
Gate 1 operating time in deceleration mode.
MOTOR 2 OPENING TIME
H4
Gate 2 opening time.
MOTOR 2 CLOSING TIME
H5
Gate 2 closing time .
MOTOR 2 DECELERATION TIME
H6
Gate 1 2 operating time in deceleration mode.
GATE 2 PHASE SHIFT TIME
DURING OPENING
H7
Delays the start of opening of gate 2 with respect to gate 1.
In the case of a configuration with double sliding gate, the time H7 is
automatically cancelled.
GATE 1 PHASE SHIFT TIME
DURING CLOSING
H8
Delays the start of closing of gate 1 with respect to gate 2.
In the case of a configuration with double sliding gate, the time H8 is
automatically cancelled.
AUTOMATIC CLOSING
PAUSE TIME
H9
Determines the pause time during opening before automatic closing.
PARTIAL OPENING TIME
H10
Determines the pedestrian opening time for the sliding gate only.
PEDESTRIAN AUTOMATIC
CLOSING TIME
H11
Determines the pause time during pedestrian opening before automatic closing.
NUMBER OF CYCLES
H12
Allows setting a number of cycles (o closing) before the maintenance
request Signalled by the light flashing for 5 minutes after the end of each
manoeuvre. The value set will always be multiplied by 10.
INSTALLER CODE
H13
Allows entering the installer code to customise the settings during programming.
CAUTION
: An already stored code can be cancelled by typing in the factory
code '0000' when requested to access programming.
In this way, however, all the existing settings are cancelled and the default
settings automatically loaded.
SOFTWARE VERSION
H14
Shows the version of the firmware installed on the board.