NETWORK COMPASS USER MANUAL
SITING THE FLUXGATE
Mount the unit upright on a flat vertical bulkhead where it will be:
•
A safe distance from external magnetic interference: 1m/3ft from VHF, RDF,
loudspeakers, depth sounders, engines, or power cables carrying heavy current
•
3m/10ft from Radar and SSB equipment
•
Externally mounted on steel hulled vessels
•
Well protected from physical damage
•
With the connector downwards
MOUNTING THE FLUXGATE
•
Secure the unit in the selected site using the self tapping screws provided
•
Route the cable to the Network COMPASS display unit avoiding other cables
carrying heavy currents (for example, engine starter or trim tabs)
•
Secure in place using cable clips or tie-wraps
•
Avoid bending the cable through a tight radius especially near the connector as
this may damage the wires inside the cable
21