1. Installation Safety Warnings!

 

WARNING!

•  The door may operate unexpectedly, therefore do not allow anything to stay in the path of 

the door.

•  When operating the manual release while the door is open, the door may fall rapidly due 

to weak or broken springs, or due to being improperly balanced. 

•  The drive must not be used with a door incorporating a wicket door, unless the drive cannot 

be operated with the wicket door open. 

•  The drive is intended to be installed at least 2.5m above the floor.
•  Do not disengage the opener to manual operation with children/persons or any objects 

including motor vehicles within the doorway.

•  If the door is closing and is unable to re-open when obstructed, discontinue use. Do not 

use a door with faulty obstruction sensing

•  When using auto close mode, a Photo Electric beam must be fitted correctly and tested 

for operation at regular intervals.  Extreme caution is recommended when using auto 
close mode.  All safety rules must be followed.

 

ELECTROCUTION!

•  Place opener in protected area so that it does not get wet.
•  Do not spray with water .

•  Disconnect the power cord from mains power before making any repairs or removing 

covers. Only experienced service personnel should remove covers from the opener.

•  If the power supply cord is damaged, it must be replaced by an Automatic Technology 

service agent or suitably qualified person.

•  Connect the opener to a properly earthed general purpose 240V mains power outlet 

installed by a qualified electrical contractor.

CAUTION:

Emergency Access

•  If garage has no pedestrian entrance door, an emergency access device should  be 

installed. This accessory allows manual operation of the garage door from outside in case 
of power failure.

Muscular strain

•  Practice correct lifting techniques (carton weighs approx 9kgs)
•  Practice correct lifiting techniques when required to lift the door as per installation instructions.

Fall from ladder

•  Ensure ladder is the correct type for job.
•  Ensure ladder is on flat firm ground that will take the weight without the legs sinking.
•  Ensure user has 3 points of contact while on ladder.

Crush injury from unsecured 
door

•  Place a 2 metre exclusion zone around area under the door while it is unsecured.
•  Follow the installation instructions

Garage Door

•  Examine the door installation, in particular, springs and mountings for signs of wear, damage 

and imbalance.

•  The garage door must be well balanced. Sticking or binding doors must be repaired by a 

qualified garage door installer prior to installation of the opener.

•  Remove or disengage all garage door locks and mechanisms prior to installation of the 

opener.

Entanglement 

•  Never plug in and operate opener prior to installation.
•  Keep hands and loose clothing clear of door and guides at all times.

Entrapment under  
operating door  

•  DO NOT operate the opener unless the garage door is in full view and free from objects 

such as cars and children/people. Make sure that the door has finished moving before 
entering or leaving the garage

•  In order for the opener to sense an object obstructing the door way, some force must be 

exerted on the object. As a result the object, door and/or person may suffer minor damage 
or injury.

•  Ensure the garage door is in good working order by undertaking regular servicing.
•  Install the optional wall transmitter in a location where the garage door is visible, but out of 

the reach of children at a height of at least 1.5m.

•  Photo Electric beams must be installed if the closing force at the bottom edge of the door 

exceeds 400N (40kg)

This automatic garage door opener is designed and tested to offer safe service provided it is installed 
and operated in strict accordance with the following safety warnings. Failure to comply with the following 
instructions may result in death, serious personal injury or property damage.

Содержание Controll-A-Door Advance

Страница 1: ...Doc 161041_00 Part 79151 Released 04 08 2016 Sectional Door Opener Instruction Manual SDO 3V2 Controll A Door S Controll A Door S PanelPro SDO 4V1 PanelPro ...

Страница 2: ...ce 10 To Increase Force Pressure 10 To Decrease Force Pressure 10 To Recall Factory Set Force 10 To Recalculate Force Margins 10 13 Auto Close Auxiliary 11 Safety Beams 11 Auto Close Option 11 Auxiliary Output 11 14 Coding a Transmitter 12 Storing the Transmitter Code 12 Coding the Courtesy Light 12 Coding Vacation Mode 12 Coding a Transmitter to enable AUX Output 12 Setting the Transmitter to Ope...

Страница 3: ... 9kgs Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door whi...

Страница 4: ...tural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii does it have exposed beams The opener is mounted to a perforated angle which must be securely fastened to a structural support like the exposed beams You may need to install a 40mm thick board not supplied between structural supports b Look at the wall above the garage door i Is it brick Th...

Страница 5: ...5 11 1 x Pin 0890 12 2 x Clevis Pin 0829 13 2 x Hex Serration flange nut M8 14 4 x Hex flange screw taptite S M4 x 10 PLUS 15 2 x Track Bracket 16 1 x Pre Assembled Single Piece C Rail 10 00 min MINIMUM HEAD ROOM FOR STEEL RAIL 25mm DOORS HIGHEST POINT 15 1 16 5 4 6 7 12 8 14 11 9 13 10 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protected from weather b REQUIRES p...

Страница 6: ... opener failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profressional for installation DIY c Using step ladder and a level transfer this height to the wall above the door and mark a line 60mm above it across the centre line Mounting The Wall Bracket a Draw two lines extending 21 5mm from...

Страница 7: ...ent moisture on the C rail running into the powerhead it is recommended a strip of silicon sealant is placed across the top of the C rail just before the opener Ceiling Beams that run towards the door requires 1 x perforated L shape metal strip and 2 x shorter perforate L shape metal drop down strips Ceiling Beams that run parallel to the door requires 2 x perforated L shape metal strips and 2 x s...

Страница 8: ...traight arm 5 with bolts 10 and nuts 13 supplied in the accessory pack Connect the straight arm 5 to the 8 7 7 12 9 4 13 6 10 9 12 8 5 10 Connect to Power Initial Preparation a Move the door to the half way position b Remove the clear button cover from the unit NOTE This cover has a label that says Do not remove however this only applies during normal operation This cover must be removed to setup ...

Страница 9: ...the MINUS button will inch the door closer to the ground c If the door overshoots press the PLUS button to move the door in the open direction d When the door is at the desired close position press the LIMIT SET button the OPEN LIMIT LED will now flash e Press and hold the PLUS button until the door reaches your desired open limit position Single presses of the PLUS button will inch the door open ...

Страница 10: ...rgins a Press and hold the FORCE MARGIN SET Button for six 6 seconds the beeper will sound once b The door will start to move and re calculate force margins The door can move between the open and close limit positions up to four 4 times depending on the position of the door and the power up condition c A single beep will be heard once the process is complete d Test the force again as per Testing C...

Страница 11: ...oken the door will remain open until the path is broken If the opener incurs a physical obstruction i e not from the Safety Beams while closing the door it will re open and not Auto Close until the Safety Beam s path is broken again To enable the Auto Close function unscrew the back cover from the opener to gain access to the control board and remove the AUTO CLS ACLS shunt next to the programmer ...

Страница 12: ...de The opener can be programmed into a Vacation Mode where the opener will not respond to any transmitter except the button of the transmitter that was programmed for vacation mode a Press the DOOR CODE button three 3 times the DOOR CODE LED will illuminate and the courtesy light will flash slowly b Press one of the four 4 buttons on the transmitter for two 2 seconds the DOOR CODE LED will begin t...

Страница 13: ...opener is in Code Learn mode If a valid code is not stored within 15 seconds the opener will exit Code Learn d Press the transmitter button one of four that you want to control the door The DOOR CODE LED will flash e Press the same transmitter button again The DOOR CODE LED will illuminate for one second then go out f The transmitter button is now coded press to test Remotely Coding Transmitters U...

Страница 14: ... wet DO NOT spray with water DO NOT open the protective covers DO NOT operate opener if cable is damaged DO NOT DO IT YOURSELF Keep the garage door balanced Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is ne...

Страница 15: ...nually re engage the opener after the door is closed 17 Operating your Opener To Operate the opener a Press the programmed transmitter button until your door begins to move usually 2 seconds Make sure you can see the door when you use the transmitter b If you are in a vehicle you should aim the transmitter through your windscreen as shown c Check that the door is fully open or closed before you dr...

Страница 16: ...tion 1 OPERATE Opens stops closes the door 2 CODING LED Red Flashes when a code is being stored or when the transmitter button is pressed 3 DOOR CODE Blue Is used for storing or erasing transmitter buttons for door operation 4 DOOR STATUS LED Yellow Illuminates when Service is due 5 OPEN LED Green Illuminates and flashes as the door opens and remains on when the open limit position has been reache...

Страница 17: ...47 433 92 434 37MHz Receiver code storage capacity 8 X Tri Tran 4 button Transmitters 8 X Tri Tran 4 button Transmitters Coding System Tri Tran Technology Tri Tran Technology Coding type Non linear encryption algorithm Non linear encryption algorithm Number of code combinations Over 100 billion random codes Over 100 billion random codes Transmitter battery CR2032 3 Volts CR2032 3 Volts Courtesy li...

Страница 18: ...t chain is not moving Damage motor assembly Contact your dealer for support The transmitter range varies or is restricted Variations are normal depending on conditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashi...

Страница 19: ... cause Remedy The SERVICE LED has started to flash and is beeping numerous times A Fault has been detected The fault will be active each time an attempt is made to operate the door Record opener function How many beeps then press the SET button once to reset the opener If the fault continues to be tripped contact 13 62 63 for support The Open Green LED and Close Red LED are flashing alternatively ...

Страница 20: ... and social benefits WARNING Prior to disposal recycling or collection all battery terminals must be securely insulated with a non conductive material to prevent any two batteries from short circuiting and generating heat during storage or transport Battery terminals may be insulated with electrical tape or batteries may be individually packaged in a non conductive material e g plastic bag or orig...

Страница 21: ...fault of 3000 cycles which is the recommended service interval AUX OSC 0V SB 2 0V SB 1 v When this counter expires the yellow SERVICE LED will light up and opener beep three times at the start of each cycle In addition the courtesy light will flash and opener beep five times at the end of open cycle when the door is fully open These warning signals will self extinguish after 30 cycles When this se...

Страница 22: ...h 6 this warranty does not extend to and B D will be relieved of all obligations responsibilities and liabilities in the event that defects in the Product are directly or indirectly in the opinion of B D due to or resulting from a unreasonable use the Product not being used correctly in accordance with the Instruction Manual or other unreasonable use b instructions failure to observe any instructi...

Страница 23: ...rsonal use when entry into the house may be via the garage Wall Button Transmitter Allows you to operate the opener within 10 metres of the door Ideal for mounting inside the house Wireless Keypad The entry keypad allows entry to the garage without using a transmitter Battery Back up The opener has a provision for a Battery Back Up kit that allows continued operation of the door in the absence of ...

Страница 24: ... 20 B D Doors is a division of B D Australia Pty Ltd ABN 25 010 473 971 Is your opener beeping or flashing It may be time for a service for more details see section 22 For a service contact your dealer using the details below Dealer copyright 2016 ...

Отзывы: