6.3
Machine Use
6.3.1
Starting the Machine
To start the machine, press the START button:
•
The display will light up and show the current temperature and preset speed
•
The VMS (Machine Working) light will light up (VST, Machine Powered, is always lit when
machine is powered on)
•
The exhaust blower(s) will run
•
The ironing cylinder will begin rotating
•
After 15 seconds of purge time, heating is enabled
6.3.2
Shut Down Procedure
To stop the machine, press the STOP button:
The shutdown procedure depends on the temperature detected by the control
•
If the temperature is less than or equal to TA, the automatic shutdown temperature, (80
◦
C by
default), the ironer will power down.
•
If the temperature is greater than TA, only the heating is turned off. When the temperature
drops below TA, the ironer will stop completely.
During the automatic shutdown procedure the temperature display and VMS indicator will flash.
The TA value can be programmed during installation if needed. Refer to Section 6.7 on page 26 for
further details.
21