10 Decommissioning 

10.1 Dismantling   

 

Disconnect the inverter from DC input and AC output. 

● Remove all connection cables from the inverter. 
● Remove the inverter from the bracket. 

10.2 Packaging 

If possible, it’s better to pack the inverter with the original packing. 

If original packing is not available, please use similar packing which meets below requirements 
● Load ability should be over 20kg. 
● With handle.   
● Able to fully closed.   

10.3 Storage 

Store the inverter in a dry place where ambient

 

temperature is always between -25 

 and +60 

-13°F to +140°F. 

10.4 Disposal 

Please put the defective inverters & packing materials to a place which is convenient for relevant 

department to dispose and recycle. 

Содержание SF1600TL

Страница 1: ...Solar Family PV Grid tied Inverter User Manual...

Страница 2: ...ion 11 4 4 General Data 11 5 Function 13 6 Installation 14 6 1 Safety Instructions 14 6 2 Selecting the Installation location 14 6 3 Preparation 15 6 4Monuting the Bracket 15 6 5Mounting the Inverter...

Страница 3: ...3000TL SF3600TL SF4200TL SF4600TL SF5000TL 1 2 Target Group This manual is for qualified personnel who have received training and demonstrated skills and knowledge in the construction and operation of...

Страница 4: ...ng given supervision or instruction Children should be supervised to ensure that they do not play with the inverter Caution Danger of burn injuries due to hot enclosure parts During operation the uppe...

Страница 5: ...d or the DC lid Beware of hot surface The inverter may become hot during operation Avoid any contact to the surface during operation Danger of high voltages Danger to life due to high voltages in the...

Страница 6: ...guidelines G83 mark The inverter complies with the requirements of the applicable G83 guidelines CQC mark The inverter complies with the requirements of the applicable CQC guidelines Safety precaution...

Страница 7: ...el must disconnect both AC and DC power from the SF series inverter before attempting any maintenance or cleaning or working on any circuits connected to the SF series inverter Warning The photovoltai...

Страница 8: ...The Solar Family Series Inverter 6 2 Introduction 2 1 Overview Figure 2 Stereogram 2 2 Electrical Block Diagram Electrical block diagram Figure 3 Electrical block diagram...

Страница 9: ...Terminals of PV Inverter Figure 4 Terminals of PV Inverter SF1600TL SF2200TL SF3000TL Figure 5 Terminals of PV Inverter SF3600TL SF4200TL SF4600TL SF5000TL 2 4 Dimension and Weight Dimension Figure6...

Страница 10: ...Solar Family Series Inverter 8 Figure7 SF3600TL SF4200TL SF4600TL SF5000TL Weight Table 1 Model SF1600TL SF2200TL SF3000TL SF3600TL SF4200TL SF4600TL SF5000TL Weight kg 13 6 13 9 13 9 17 2 17 5 17 5 1...

Страница 11: ...9 3 Packaging List Table 2 The Solar Family is shipped with the following items Figure 8 Item Name Quantity A Solar Inverter 1 B Mounting Frame 1 C Mounting Screws 4 D Mounting Frame Screws Sleeve 4...

Страница 12: ...ber of MPP Trackers Strings per MPP Tracker 1 1 2 1 MPPT Voltage Range V 120 500 170 500 210 500 120 500 150 500 160 500 175 500 Nominal PV Voltage V 360 360 Start Voltage On Grid Voltage 100 120 100...

Страница 13: ...x Efficiency 97 7 97 8 97 8 98 1 98 1 98 1 98 1 Euro Efficiency 97 0 97 1 97 2 97 3 97 4 97 5 97 6 MPPT Efficiency 99 9 99 9 Overvoltage Under Voltage Protection Yes Yes Shutdown Voltage Start Voltage...

Страница 14: ...condensing Pollution Degree External III Internal II External III Internal II Protective class Class Class Degree of Protection IP65 IP65 Topology Transformerless Transformerless Internal Consumption...

Страница 15: ...the Self Testing mode On grid Mode Under this mode SF series inverters convert PV array s DC into AC and feedback into grid Fault Mode If any fault error occurs inverter stops generating power until...

Страница 16: ...ntact with your local distributor or service center Although designed to meet all safety requirements some parts and surfaces of inverter are still hot during operation To reduce the risk of injury DO...

Страница 17: ...tall horizontally Figure 9 6 3 Preparation Below tools are needed before installation Figure 10 Installation Tools 6 4 Mounting the bracket Inverter requires adequate cooling space Allow at least 20cm...

Страница 18: ...nverter 16 Using the mounting frame as a template drill 3 holes as illustrated in image Figure 12 Fix the mounting frame as the figure shows Do not make the screws too close to the wall leaving 2 4mm...

Страница 19: ...The Solar Family Series Inverter 17 6 5 Mounting the Inverter Hang the inverter onto the mounting frame Figure 14 Insert safety lock screws into the bottom leg to fasten the inverter Figure 15...

Страница 20: ...PV1 F cables can be used The T V approval only allows the use of PV1 F cables Do not use type H07RN F cables The connectors must be not disconnected while under load For protection against electric sh...

Страница 21: ...Nm using a suitable tool Finished Connector socket unlocking process Figure 17 1 Insert screwdriver SZF 1 or phase tester in one of the illustrated positions 2 Leave screwdriver inserted and remove co...

Страница 22: ...inverter and utility grid 3 Connect AC wires of inverter as follows Figure 20 Below is the AC cable specification table when select the cable for installation Table 7 Cable and Micro breaker Requirem...

Страница 23: ...is starting On The DC DC Circuit is working normally 7 1 2 DC AC status LED Green Table 9 Off The DC AC Circuit is off Blinking The DC AC Circuit is starting On The DC AC Circuit is working normally 7...

Страница 24: ...backlight will turn off automatically after 30 seconds When the LCD is dark one tap will make it become bright again A summary diagram of the display functions is shown as the figure below the LCD wil...

Страница 25: ...Derating If the Power derating occurs the detailed reason will show in MESSAGE page Next to the Power status symbol the LCD displays operation condition Waiting Mode Self Testing Mode On grid Mode an...

Страница 26: ...11 Display Description Leakage Fault The internal hardware that measures ground fault has measured substantially high ground currents Grid Fault Grid Voltage or Frequency out of range Boost Fault Boo...

Страница 27: ...r Panel array 1 Ipv1 Current from Panel array 1 Vpv2 Voltage for Panel array 2 Ipv2 Current from Panel array 2 Vgrid Grid Voltage Fgrid Grid frequency Iout Current exported to the grid Vbus DC bus vol...

Страница 28: ...ting Page Figure 31 Country The Grid Standard of the Inverter can work GER 11 DIN VDE V 0126 1 1 2006 A1 2011 AUS 11 AS 4777 2005 GBR 12 G83 Issue 2 August 2012 GBR 22 G59 Issue 2 August 2010 GER 21 V...

Страница 29: ...er setting then disconnect the dial switch 3 off Notes Make sure dial switch 3 is disconnected Off when the inverter is working or else the inverter can t work properly then Setting working mode If yo...

Страница 30: ...anage the entire power system We offer below three types of communications Figure 33 Communication Interface of SF Series Inverter Table 12 3 line RS485 Wire No Function Serial Port Wire No Function 1...

Страница 31: ...ection way between SF Series Inverters are a straight through cable But the connection between SF Series Inverters and Webbox uses a crossover cable As shown in the following figure Figure 35 Web Box...

Страница 32: ...ed WiFi Communication optional Embeded WiFi module is a hardware device can be inserted to inverter s serial port Please refer to WiFi module Manual for more information Table 13 1 2 4 3 1 2 3 4 Inver...

Страница 33: ...grid usability Or seek for help from us PV Over Voltage Checking the panel s open circuit voltage whether the value is close to or already Max DC voltage Please seek help from us when voltage Max DC...

Страница 34: ...ed in a clean dry ventilated place Have the DC input breakers been opened Is the size length of cables suitable Are the input and output connections and wiring in good condition Are the configurations...

Страница 35: ...e inverter with the original packing If original packing is not available please use similar packing which meets below requirements Load ability should be over 20kg With handle Able to fully closed 10...

Страница 36: ...to the following products SF1600TL SF2200TL SF3000TL SF3600TL SF4200TL SF4600TL SF5000TL Limited Product Warranty Applicable under normal application installation use and service conditions SF Series...

Отзывы: