background image

4

COMMUNICATION PORTS

COMMON

+24 VDC

+24

N/C

COMM

WIRING

POWER CONNECTION

PROGRAMMING PORTS

RS23

2

RTS

COMM

Tx

COMM

CTS

Rx

YELLOW LED

GREEN/AMBER LED

ETHERNET

RS232

CF

RS485

USB/PG

RS232/PG

STS

OR

Ethernet (Crossover)

OR

Tx

RS232

RTS

COMM

COMM

CTS

Rx

RS232

RS485

USB/PG

RS232/PG

ETHERNET

CF

STS

CHASSIS GND

OR

REM

SLC 5/03 CPU

RUN

BATT

FLT

RUN

RS232

DH485

FORCE

PROG

VDC

PWR OUT +24

PWR OUT COM

VAC NEUT

120/240 VAC

USER

POWER

POWER

RS232/PG

USB/PG

RS232/PG

ETHERNET

WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT 

WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE 

NON-HAZARDOUS.

INPUT AND OUTPUT (I/O) WIRING MUST BE IN 

ACCORDANCE WITH CLASS I, DIV. 2 WIRING METHODS 

AND IN ACCORDANCE WITH THE AUTHORITY HAVING 

JURISDICTION.

Содержание VLINX VFG1000

Страница 1: ...ce which can be purchased as part of a kit that includes a manual and cables or downloaded free of charge SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the...

Страница 2: ...use only Installation Category II Pollution Degree 2 8 POWER CONNECTION Removable wire clamp screw terminal block Wire Gage Capacity 24 AWG to 12 AWG Torque 4 45 to 5 34 in lb 0 5 to 0 6 N m 9 MOUNTI...

Страница 3: ...ession devices is effective The following EMI suppression devices or equivalent are recommended Ferrite Suppression Cores for signal and control cables Fair Rite part number 0443167251 TDK part number...

Страница 4: ...485 USB PG RS232 PG ETHERNET CF STS CHASSIS GND OR REM SLC 5 03 CPU RUN BATT FLT RUN RS232 DH485 FORCE PROG VDC PWR OUT 24 PWR OUT COM VAC NEUT 120 240 VAC USER POWER POWER RS232 PG USB PG RS232 PG ET...

Страница 5: ...the available cables WARNING Do NOT use a standard DH 485 cable to connect this port to Allen Bradley equipment PORT 3 ETHERNET CONNECTION RS232 RS485 5 EXPANSION 24VDC 10 USB PG TxA PIN 8 GREEN YELL...

Страница 6: ...lished if your Fieldbus Gateway was configured using the USB port Once the driver is installed connect the Fieldbus Gateway to your PC with a USB cable and follow Mounting the CompactFlash instruction...

Страница 7: ...ft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in...

Страница 8: ...l Headquarters 707 Dayton Road P O Box 1040 Ottawa IL 61350 Phone 815 433 5100 Fax 815 433 5104 B B Electronics Ltd European Headquarters Westlink Commercial Park Oranmore Co Galway Ireland Phone 353...

Отзывы: