B&B Electronics ULinx UEC100M/4 Скачать руководство пользователя страница 2

Manual Documentation Number: UEC100M/4-2305 

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

 
 

Thank you for purchasing the Ulinx Extender. Please 

read this guide thoroughly before installation. 

 
 
 
 
This document applies to Part Numbers: UEC100M/4,  UEC100M/4-EU and  
UEC100M/4-UK. 
 

FCC Radio Frequency Interference Statement Warning 

The Ulinx Extender has been tested and found compliant with the limits for a 
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when installed and operated in a commercial environment. The Ulinx 
Extender generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with this user guide, may cause 
harmful interference to radio communications. Operation of the Ulinx 
Extender in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own expense.  

CE Statement 

Conforms with European Standard EN 55022/A1 Class A, and EN 50082-1 
(IEC 801-2, IEC 801-3, IEC 801-4) 

IC Statement 

This Class A digital apparatus complies with Canadian ICES-003. 
 

 
 

 
 
 
 
 
 
 

 

 

Manual Documentation Number: UEC100M/4-2305 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

 

Содержание ULinx UEC100M/4

Страница 1: ... com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb europe com Sales e mail sales bb europe com Technical Support e mail support bb europe com B B Electronics Mfg Co Inc June 2005 Manual Docume...

Страница 2: ...rmful interference when installed and operated in a commercial environment The Ulinx Extender generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user guide may cause harmful interference to radio communications Operation of the Ulinx Extender in a residential area is likely to cause harmful interference in which case the user will be require...

Страница 3: ...OUT THE ULINX EXTENDER 2 BEFORE YOU BEGIN 5 INSTALLING THE LOCAL UNIT 5 INSTALLING THE REMOTE UNIT 5 CONNECTING THE LOCAL UNIT TO THE REMOTE UNIT 6 CHECKING THE INSTALLATION 6 CONNECTING A USB DEVICE 7 TROUBLESHOOTING 8 SPECIFICATIONS 11 CONTACTING TECHNICAL SUPPORT 12 ii Manual Documentation Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100...

Страница 4: ...th of the Category 5 UTP cable including patch cords must not exceed 100m 2 Manual Documentation Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com About the Ulinx Extender The Ulinx Extender b...

Страница 5: ... bb europe com USB Cables USB cables have two distinct connectors The Type A connector is used to connect the cable from a USB device to the Type A port on a computer or hub The Type B connector is used to attach the USB cable to a USB device USB Type A port USB Type A connector USB Type B port USB Type B connector Power Handling Some USB devices are powered directly from the USB and do not requir...

Страница 6: ...Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Connecting the Local Unit to the Remote Unit NOTE To ensure proper operation we recommend that only Category 5 or better Unshielded Twisted Pa...

Страница 7: ...r further assistance see page 12 Symptoms Cause Remedy All LEDs on Local Unit and Remote Unit are off Cause The Ulinx Extender is not receiving power from the adapter 1 Ensure that the power adapter is connected to the Local Unit or Remote Unit 2 Check that the adapter is connected to a live source of electrical power Power LED on one unit is on power LED on other unit is off Cause There is no con...

Страница 8: ...when directly connected to the computer connect another device of a different type to the Ulinx Extender Connect the Ulinx Extender to the computer 5 If the second device does not operate the Ulinx Extender may be malfunctioning Contact technical support for assistance 6 If the second device does operate properly the first device may not be compatible with the Ulinx Extender Contact technical supp...

Страница 9: ...A Local Unit dimensions 10 7 x 8 4 x 3 4 cm 4 3 x 3 4 x 1 4 in Local Unit weight 0 3 kg 0 6 lb Remote Unit dimensions 10 7 x 8 4 x 3 4 cm 4 3 x 3 4 x 1 4 in Remote Unit weight 0 3 kg 0 6 lb Total system shipping weight 1 1 kg 2 4 lb Temperature range 4 C to 40 C Regulatory testing FCC CE Class A 12 Manual Documentation Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Otta...