RECONFIGURING TO FAC TORY SETTINGS
The MES1A and MES1B come from the factory preconfigured for correct operation
with their respective interfaces. The following procedure describes how you can
return the MES1A and MES1B to their original factory settings.
TO RECONFIGURE THE MES1A TO FACTORY SETTINGS:
Type
D
at the
Select Command or parameter set (1..4) to change:
prompt. The
Configuration Menu is updated with the new settings displayed.
TO RECONFIGURE THE MES1B, TO FACTORY SE TTINGS:
14.
Type
D
at the
Select Command or parameter set (1..4) to change:
prompt.
15.
Type
2
to enter the Serial & Mode Settings section and set the
Serial Mode
for
RS-485 Two-Wire
(see the next section for details).
16.
Type
3
to enter the
Modem/Configurable Pin Settings
section and
set
CP1
to
RS-485 Enable Wire
(see the next section for details).
.
See the following sections for details on how to set
Serial & Mode Settings
and
Modem/Configurable
Pin Settings
.
NETWORK/IP SETTINGS
In the
Network/IP Settings
section of the Configuration Menu you can configure:
IP Address
of the MES1A/B
Default Gateway
Netmask
Telnet Configuration Password