Manual Documentation Number M3640D1598
15
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Can measure up to 20 MHz with 5 steps of 2, 20, 200KHz, 2, 20 MHz (for
M-3650D/3660D).
34. TEMP Temperature (M-3640D/M- 3660D only)
Can measure from -40
°
C to 1200°C by using the optional K-type
thermocouple.
35. CAP Capacitance (Except M-3610D)
Let you to measure capacitance from LO: nF 2, 2O, 200 to Hi: uF 2, 20,
200.
36. hFE Transistor hFE (Except M-3610D)
Enables you to measure hFE value.
37. LOG Logic Test
Enables you to check logic levels without extra logic probes. This function
displays Hi, Lo or ••• to indicate logic high, logic low, or undetermined,
respectively.
38. dB Decibels (M-3640D/3660D only)
Enables to check the logarithmic ratio of input voltage to the standard
stored value.
39. Sub-display
Lets you see the secondary readings in all function modes.
40.
Low Battery
Meter is powered by a single 9V battery. At least 8 hours of battery life
remain when
is first displayed.