Threshold Pot 

 

The large pot in the center of the 485T is the threshold pot.  In 

order for RS-422/485 to work properly, you should have a differential 
input voltage of more than .2 volts across the two lines at the RS-
422/485 receiver.  By adjusting this pot you can determine the 
amplitude of the RS-422/485 signals.  Start with the knob turned 
down to zero volts (full clockwise) with data being sent on your 
network.  The Data LED should be blinking with the data providing 
that the network is not running at too high of a baud rate.  At higher 
baud rates the LED may be on.  Turn the threshold pot up 
(counterclockwise) until the Data LED stops blinking or turns off.  
The reading of the pot at that point is the differential input voltage.  
This reading should be .2 volt or more.  If the LED does not stop 
blinking or turn off with the pot all the way up (full counterclockwise) 
the reading is above 1 volt.  Readings above 1 volt are not available 
since it would make the lower voltage readings difficult to read.  
Readings above 1 volt indicate that differential voltage is more than 
adequate. 

Positive Threshold Exceeded LED

 

 

 

The RS-422 Standard states that a network should not have a 

positive common mode voltage of more than 7 volts.  This means 
that the difference between Signal Ground and either the A or B 
input should not be more than positive 7 volts.  For RS-485 the 
maximum is 12 volts.  The Positive Threshold Exceeded LED will 
light if these limits are exceeded.  This reading is taken with respect 
to Signal Ground so the GND terminal must be connected properly 
for the reading to be correct. 

 
 NOTE:

  The RS-422/RS-485 switch is used to control this 

threshold.  It must be in the proper position for these readings to 
be correct. 

Negative Threshold Exceeded LED 

   

Both the RS-422 and the RS-485 Standards state that the 

network should not have a negative common mode voltage of more 
than 7 volts.  This means that the difference between Signal Ground 
and either the A or B input should not be more than minus 7 volts.  
The Negative Threshold Exceeded LED will light if this limit is 
exceeded.  Again this reading is taken with respect to Signal Ground 
so the GND terminal must be connected properly for the reading to 
be correct. 

 

Содержание 485T

Страница 1: ... product Designed and Manufactured In Ottawa Illinois USA of domestic and imported parts by B B Electronics Mfg Co Inc 707 Dayton Road P O Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 Internet http www bb elec com orders bb elec com support bb elec com 1992 B B Electronics Revised August 1992 Not Recommended for New Installations Please contact Technical Support for more information ...

Страница 2: ...3 5105 TABLE OF CONTENTS INTRODUCTION 1 RS 422 AND RS 485 STANDARDS 1 CONTROLS AND CONNECTIONS ON THE 485T 6 A AND B TERMINALS 6 GROUND TERMINAL 6 THRESHOLD POT 7 POSITIVE THRESHOLD EXCEEDED LED 7 NEGATIVE THRESHOLD EXCEEDED LED 7 RS 422 RS 485 SWITCH 8 TERMINATION SWITCH 8 POWER 8 RS 232 DATA OUT CONNECTOR 8 RS 422 485 TEST 9 ...

Страница 3: ...re usually located close to each other wire length was not much of a factor in the standard RS 232 maximum wire lengths were set at 50 feet RS 232 lines can run farther with special low capacitance wire but there is a practical limit of 300 or so feet The EIA then developed two newer standards to allow serial data communications to go past the 50 foot barrier The first is RS 422 Electrical Charact...

Страница 4: ...a Typically the RS 422 or RS 485 driver will switch between 5 volts and ground Since devices can be long distances apart they can be powered on different power lines or transformers that can force their reference grounds to be at different voltages The RS 422 Standard allows the signal lines to go as high as 7 volts and as low as 7 volts The RS 485 Standard allows 12 volts and 7 volts Another requ...

Страница 5: ...Documentation Number 485T1995 Manual 3 B B Electronics PO Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 ...

Страница 6: ...4 Documentation Number 485T1995 Manual B B Electronics PO Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 ...

Страница 7: ...Documentation Number 485T1995 Manual 5 B B Electronics PO Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 ...

Страница 8: ...m as two separate networks You would first run your tests on one pair of signal lines and then run them again on the other pair NOTE Make sure that you are connected to the correct two lines when using the tester It is possible for the tester to look like it is working properly when one line is connected and the other is floating or connected to a wire in another pair Ground Terminal The GND termi...

Страница 9: ...d make the lower voltage readings difficult to read Readings above 1 volt indicate that differential voltage is more than adequate Positive Threshold Exceeded LED The RS 422 Standard states that a network should not have a positive common mode voltage of more than 7 volts This means that the difference between Signal Ground and either the A or B input should not be more than positive 7 volts For R...

Страница 10: ...network with no terminations and want to see what happens if you terminate it at one point Normally you should leave this switch OFF down Power The 485T will work from a nine volt battery or from 12 VDC through the 2 5 mm jack marked DC Power 12VDC IN When you plug in the external power supply available from B B Electronics as the Model 485PS the battery is automatically disconnected RS 232 Data O...

Страница 11: ...g sent and when the network is idle If either of these LEDs is on or blinking you may have a grounding problem You should first check that the RS 422 RS 485 switch is in the proper position and that the Signal Ground is connected correctly to the 485T Refer to B B Electronics free RS 422 485 Application Note for information on proper grounding of your network NOTE If the positive or negative thres...

Страница 12: ...olt Most RS 422 485 drivers start out with a differential of about 2 volts but the resistance inductance and capacitance in the line can reduce it considerably NOTE The differential voltage you are trying to measure is the RECEIVED voltage You should only make the threshold measurement when the node you are testing is RECEIVING data not when it is transmitting If you have a multiple node system wi...

Страница 13: ... for handshake loopback Pin 7 is ground and there is no connection to pin 3 NOTE If the data you receive is garbled you may have the A B connectors backwards Try reversing them With the 485T connected and the THRESHOLD pot turned to zero full clockwise any RS 422 485 data on the network will appear as RS 232 data at pin 2 of the RS 232 DATA OUT jack If you have a four wire network you can only vie...

Страница 14: ...12 Documentation Number 485T1995 Manual B B Electronics PO Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 ...

Отзывы: