Operation
The host computer of the RS-485 network controls each
485DSS on the network by sending them command messages.
These commands can turn a 485DSS on or off, and can also request
status from an individual or from all of the 485DSS's on the network.
The communication setup used to send and receive these
commands are: 9600 baud, 8 data bits, no parity, and 1 stop bit.
Each command consists of four characters: a start of message
character, two address characters, and the command character. All
485DSS's on the network will receive the command message strings
sent by the Host, but only the 485DSS with the matching address will
execute the command. Execution of the
ON
command raises the
R
equest
T
o
S
end (RTS) output line on pin 4 of the DB25 connector
and connects the RS-232 port to the RS-485 network. Once
ON
(selected), the RS-232 device can transmit and receive data to the
HOST. Executing the
OFF
command lowers the RTS line,
disconnecting the RS-232 port from the network. The RS-232 port of
the 485DSS is
OFF
(not selected) at power up. The 485DSS does
not buffer or delay any data passing through the unit.
ALL
data that
is sent from the RS-485 device will be passed through to the RS-232
side while the unit is selected including the next set of command
characters.
The Host can poll any or all 485DSS's on the network using the
request status command. This allows the Host to determine if any
485DSS is requesting access to the network by monitoring the
handshake status character returned by the 485DSS. The status
character reflects the state of the input handshake signal
C
lear
T
o
S
end (CTS) on the RS-232 connector pin 5. With this feature the
Host has the ability to prioritize each 485DSS on the network. Refer
to Figure 2.