4.10 Set Operator Handing (Inside Looking Out)
1.
With power off, move the gate
to the close position with the
limit plate in front of the close
limit switch.
2.
While holding down STOP and
CLOSE buttons on supplied 3
button station, turn operator
power on.
3.
Wait for the alarm to sound
(date and
time will flash on first
power up), then
release the
STOP and CLOSE buttons.
Handing is now set.
4.10.1 HCMSGOFF Parameter
The LXL operator now has the ability to
display a message if the Handing has
been changed. To enable this setting;
1.
From the main menu, select ‘Set
Param’.
1.
Press the UP grey arrow key and
scroll through the options to
HCMSGOFF
2.
Press OK.
3.
The S on Switch will start flashing
4.
Use the arrow keys to Off to On
5.
Press OK to save
HCMSGOFF
Switch-Off