1) Safety Precautions

What you 

must

 do:

• 

Read  these  instructions  before  using 

your air compressor.

• 

Ensure  the  compressor  has  been 

installed, 

electrically 

connected 

and  piped  in  by  a  properly  qualified 

person.

• 

Ensure the compressor is kept upright 

at all times.

What you 

must not 

do:

• 

Do not attempt any maintenance on the 

compressor until it has been isolated 

from the power supply.

• 

Do  not  attempt  any  work  on  the 

compressor until the air receiver and 

pipe work systems are depressurised.  

• 

Compressed  air  is  dangerous  if 

misused and can prove fatal.  Avoid 

any bodily contact with compressed 

air.

• 

During operation the motor will become 

quite hot to the touch.  Avoid contact 

to prevent burns.  

• 

Never  tamper  with  the  pressure  relief 

valve.

• 

Never  lubricate  the  oil  free  motor  or 

pump  assembly;  this  will  cause 

severe damage.

• 

Never  obstruct  cooling  fans  or  outlet 

vents.

2) Siting The Compressor

What you 

must

 do:

• 

Provide  adequate  protection  from  the 

weather.

• 

Site  the  compressor  level  in  both 

planes.

• 

Allow  access  for  maintenance  all 

around the compressor.

• 

Site  in  a  dry  area,  avoiding  damp  or 

humid conditions.  The site must be 

dust free, well ventilated and have a 

cool ambient temperature. 0 to 40°C 

should be regarded as the minimum 

and maximum allowable ambient.

What you 

must not

 do:

• 

Enclose  the  compressor  or  allow  hot 

air  generated  by  the  motor  to  re-

circulate  around  the  compressor.  

Ensure  there  is  30cm  clearance 

around the compressor

• 

Restrict air flow around the end cover 

ventilation grilles.

Important !

These  compressors  generate  heat.  

Never restrict any of the ventilation grilles 

otherwise serious damage may occur.

Electrical Connections

Where applicable, compressors are supplied with a moulded plug in accordance with 

national standards.   

Never remove the moulded plug.

The use of extension cables is not recommended as this may cause voltage drops 

which can result in damage to the motor

110v/60Hz  models wired in accordance

with US Standard –

White = neutral

Black = live,

Yellow = earth

220v/50Hz models wired in accordance

with European Standard –

Blue = neutral

Brown = live,

Yellow & Green Stripe = earth

1

Содержание PT8

Страница 1: ...Handbook PT models Covering Models BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT Tel 0121 322 2299 Fax 0121 322 2297 Email sales bambi air co uk www bambi air co uk PT5...

Страница 2: ...the company Provided the operating instructions have been followed and the compressor has been properly maintained Bambi PT compressors are guaranteed against faulty workmanship for a period of 1 yea...

Страница 3: ...te the compressor level in both planes Allow access for maintenance all around the compressor Site in a dry area avoiding damp or humid conditions The site must be dust free well ventilated and have a...

Страница 4: ...ng the unloader valve discharging the residual delivery pipe pressure This is normal Adjusting Outlet Pressure Use the pressure regulator to adjust the outlet pressure To increase line pressure rotate...

Страница 5: ...e Technical We recommend the compressor has a maximum 65 duty cycle to prolong pump life Note The motor must never be allowed to run continuously otherwise it will overheat and may become damaged The...

Страница 6: ...r BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Extension BPB0150 16 Connector BPB0810 17 50mm tank pressure gauge BPB1081 18 Delivery...

Страница 7: ...r BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Tee piece MFF BPB1109 16 Connector BPB0810 17 50mm tank pressure gauge BPB1081 18 Delivery pipe BPB1258 19 Connector BPB1242 20 Te...

Страница 8: ...BPB0066 7 Drain pipe BPB0414 8 Pressure relief valve BPB1084 9 Pressure switch BPB1074 10 Adapter BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BP...

Страница 9: ...PB1074 10 Adapter BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Siphon tube BPB0028 15 Connector BPB0152 16 50mm tank pressure gauge BPB1081 17 Delivery pip...

Страница 10: ...art no 1 Cylinder head seal BPB1250 2 Valve plate assembly BPB1251 3 Cylinder BPB1253 4 Connecting rod BPB1254 5 Top washer BPB1254 6 Piston ring BPB1254 7 Airway tube inc O ring seal BPB1252 8 Motor...

Страница 11: ...Date installed____________________________ Date Maintenance work Signature Company BPPT 1 Service Kit covers all models PT50D requires two kits SERVICE KITS BPB0655 required to change the Coalescing F...

Страница 12: ...Europea listada abajo Bambi Air Compressors verklaart dat dit product voldoet aan de onderstaande Europese Richtlijnen Bambi Air Compressors erklart hiermit dass dieses Produkt mit den Bestimmungen de...

Отзывы: