TYPE OF IRREGULARITY

The burner goes to lock-out with the flame on 
(Red lamp on).
The trouble is in the flame control device. 

The burner goes to lock-out spraying fuel but the 
flame does not ignite (Red lamp on).
The trouble is in the ignition device, providing 
the  fuel  is  in  a  good  condition  (not  polluted) 
with water or other impurities) and sufficiently 
atomized. 

The burner goes to lock-out spraying fuel but 
the flame does not ignite (Red lamp on). 

The burner goes to lock-out without spraying 
fuel (Red lamp on).

 

Noisy burner pump 

Burner does not start

POSSIBLE CAUSE

1) Photoresistance severed or fouled with smoke
2) Insufficient draught

3) Photoresistant-cell circuit severed
4) Fouled disk or orifice 

1) Ignition circuit severed
2) The ignition transformer leads have dried up

3) The ignition transformer leads are not properly 

connected

4) Ignition transformer severed
5) The electrode tips are not at the correct dis

-

tance

6) Electrodes discharge to earth because they are 

dirty or their insulation is cracked: check also 
underneath the insulator clamps 

1) Pump pressure is not normal
2) Water in the fuel

3) Too much combustion air
4) Air passage between the disk and orifice closed 

too much

5) Nozzle worn out or fouled 

1) One phase missing
2) Electric motor inefficient
3) Gas oil not reaching the pump
4) No gas-oil in the tank
5) Gate valve on the suction pipe closed
6) Nozzle clogged
7) Motor (three-phase) rotates in the wrong direc

-

tion (see arrow)

8) Bottom valve leaking or jammed
9) Defective pump
10) Inefficient solenoid valve
11) Voltage too low 

1) Pipe diameter too small
2) Air infiltration in the pipes
3) Dirty filter
4) Excessive distance between the tank and the 

burner or a lot of accidental leakage’s (elbows, 
curves, choking etc.)

5) Deteriorated flexible pipes 

1) Thermostats (boiler/room) or pressure switches 

openì

2) Photoresistant-cell in short circuit
3)  No  voltage  with  an  open  isolating  switch  or 

with  a  tripped  max.  contactor  switch  or  line 
voltage failure

4) Thermostat line not wired according to diagram 

or open thermostats

5) Trouble inside the control box

REMEDY

1) Clean or replace it
2) Check all the smoke ducts in the boiler and in 

the chimney

3) Replace the unit
4) Clean 

1) Check the entire circuit
2) Replace them

3) Tighten them

4) Replace it
5) Re-set them in the required position

6) Clean or replace them, if necessary 

1) Re-set it
2) Remove it from the tank with a suitable pump 

(never use the burner for this job).

3) Reduce the amount of combustion air
4)  Rectify  the  position  of  the  combustion  head 

adjusting device

5) Clean or replace it 

1) Check the supply line
2) Repair or replace it
3) Check the suction pipe
4) Fill up
5) Open it
6) Remove and clean it thoroughly
7) Change one phase in the
  supply switch
8) Remove and clean it
9) Replace it
10) Check and replace, if necessary
11) Contact the electric company 

1) Replace it according to instructions
2) Check and eliminate infiltration’s
3) Remove and wash it
4) Adjust the length of the suction pipe and shorten 

its distance

5) Replace them 

1) Raise the setting or wait until they close owing 

to natural temperature or pressure drop

2) Replace it
3)  Close  the  switches  or  wait  for  voltage  reac

-

tivating

4) Check the connections and the thermostats

5) Replace it

HOW TO FIND THE CAUSES OF IMPROPER WORKING OF BURNERS USING TWO-STAGE LIGHT OIL 

AND HOW TO RECTIFY THEM

Содержание TBL 45P

Страница 1: ...br l rler i in kullan m k lavuzu Instruction for burners model Instrucci nes para quemadores modelos Mode d emploi brule r TBL45P TBL60P 0006081349_200802 TR GB SP FR TBL45PDACA TBL60PDACA...

Страница 2: ......

Страница 3: ...e se corre el riesgo de que se produzcan accidentes peligrosos Avant de commencer utilise le br leur lire attentivement les recommandations de la notice RECOMMANDATIONS A L ATTENTION DE L UTILISATEUR...

Страница 4: ...n accordance with the European Standards EN 676 gas and dual fuel gas side EN 267 light oil and dual fuel oil side EN 60335 1 2001 A1 2004 A11 2004 A2 2006 EN 60335 2 102 2006 EN 50165 1997 A1 2001 EN...

Страница 5: ...or if the owner moves and leaves the equipment make sure that the booklet always goes with the equipment so it can be consulted by the new owner and or installer For all equipment with optionals or k...

Страница 6: ...rrent law and regulations since incorrect installation may cause damage to person animals or things for which damage the manufacturer shall not can be held responsible Before installation it is advisa...

Страница 7: ...CTION RATING IP 40 IP 44 versione DACA FLAME DETECTOR PHOTORESISTACE NOISE dBA 73 75 WEIGHT kg 38 40 Fuel max viscosity light oil 5 5 cst 20 C 1 5 E 20 C FLOW RATE MAX kg h 37 9 50 6 MIN kg h 13 5 21...

Страница 8: ...15 200 245 M12 145 TBL 60P 505 260 245 455 325 130 840 140 350 150 152 260 225 300 M12 160 TBL 60P DACA 535 260 275 455 325 130 880 140 350 150 152 260 225 300 M12 160 1 Combustion head 2 Gasket 3 Bur...

Страница 9: ...Un lock switch button N 0002935350 REV 26 11 07 N 0002935510 REV 07 02 08 13 Equipment 14 Ignition transformer 15 Motor contactor only for three phase power supply 16 Thermal relay only for three pha...

Страница 10: ...ipes For unavoidable joints we recommend the use of biconic fittings The annexed tables show the indicative diagrams for the different types of systems depending on the position of the tank in respect...

Страница 11: ...One way valve 10 Bottom valve SUCTION TYPE FEEDING SYSTEM N B For any missing devices in the piping follow existing regulations H Difference in level between level in the tank and the pump axis L Max...

Страница 12: ...ion pipes should be sized to cope with the delivery rate of the auxiliary pump Always avoid to electrically connect the auxiliary pump directly to the remote control switch of the burner motor HYDRAUL...

Страница 13: ...y insert the two 7 and 4 pole plugs in the sockets located below the electrical panel base as shown in figure 1 2 In the case of models with three phase power supply unscrew the 2 screws 1 and pull ba...

Страница 14: ...e see figure 2 In the case of a three phase burner connect the power supply cables 4 to the contactor fix the ground cable 5 and tighten its cable holder 3 Reposition the cable float plate as in figur...

Страница 15: ...ned by the position in which the the hydraulic control jack is set see 0002935420 If the air adjustment servo motor is used see 0002935210 If the flame appears normally with the safety time set by the...

Страница 16: ...ure that a Feedinglineconnectionstothermostatsorpressureswitchesare made exactly according to electric diagram of the control box b Check if there is fuel in the tank and water in the boiler c All the...

Страница 17: ...emove the photo cell from its seat and pull it out and simulate flame failure by covering the photo cell use a rag to close the window in the photocell support The burner flame should go to lock out c...

Страница 18: ...the air damper that regulates the aspiration flow from the burner fan This must of course be the case when the burner is working at maximum desired supply In practice you have to start the adjustment...

Страница 19: ...ll burner and remove pawl 5 with screw 6 that regulates the position of the mixer assembly figure 2 Important Before carrying out the above procedure store in memory the exact position of the mobile p...

Страница 20: ...air damper G Air intake H Support eyelet Adjustment of 1st flame air damper position 1 To increase air supply capacity turn ring nut C1 anticlockwise use counter wrench on body A of the jack to preve...

Страница 21: ...sition indicator To modify the regulation of the cams utilized operate the respective rings I II III The index of the ring indicate on the respective reference scale the rotation angle taken up for ea...

Страница 22: ...16 52 3 00 3 50 11 13 11 90 12 62 13 30 13 95 14 57 15 17 15 74 16 29 16 83 17 34 17 85 18 34 18 81 19 28 3 50 4 00 12 72 13 60 14 42 15 20 15 94 16 65 17 33 17 99 18 62 19 23 19 82 20 40 20 95 21 50...

Страница 23: ...low 1 Pipe diameter too small 2 Air infiltration in the pipes 3 Dirty filter 4 Excessive distance between the tank and the burner or a lot of accidental leakage s elbows curves choking etc 5 Deteriora...

Страница 24: ...el 3 Smoke temperature too low below 180 C 1 Excessive cooling below 180 C of smoke before exit outflow for an outside chimney not adequately heat insulated or cold air infiltration REMEDY 1 Re set it...

Страница 25: ...2 STAGE THERMOSTAT I THERMOSTAT 2 STUFE I TERMOSTATO 2 ETAPA TA ATE LEME TRANSFORMAT R TRASFORMATEUR D ALLUMAGE IGNITION TRASFORMER ZUNDUNGSTRASFORMATOR TRANSFORMADOR TC KAZAN TERMOSTATI THERMOSTAT CH...

Страница 26: ...SET PUSH BUTTON ENTSPERRKNOPF PULSADOR DE DESBLOQUEO SG ANAANAHTAR INTERRUTTORE GENERAL GENERAL SWITCH ALLGEMEINER SCHALTER INTERRUPTOR GENERAL T2 TERMOSTAT 2 A AMA THERMOSTAT 2 ETAGE 2ND STAGE THERMO...

Страница 27: ...OR DE DESBLOQUEO T2 TERMOSTAT 2 A AMA I THERMOSTAT 2 ETAGE 12 STAGE THERMOSTAT I THERMOSTAT 2 STUFE I TERMOSTATO 2 ETAPATA ATE LEME TRANSFORMAT R TRASFORMATEUR D ALLUMAGE IGNITION TRASFORMER ZUNDUNGST...

Страница 28: ...LTER INTERRUPTOR ENC APAG S2 D ME A IK BOUTON DE DEBLOCAGE RE SET PUSH BUTTON ENTSPERRKNOPF PULSADOR DE DESBLOQUEO SG ANAANAHTAR INTERRUTTORE GENERAL GENERAL SWITCH ALLGEMEINER SCHALTER INTERRUPTOR GE...

Страница 29: ...a por lo tanto se reserva cualquier posibilitad de modificati n de datos t cnicos y otras anotaciones Ce manuel rev t caract re purement indicatif La maison se reserve la possibilit de modifier des do...

Отзывы: