MODEL
TBG 210 MC
TBG 260 MC
TBG 360 MC
MAXIMUM NATURAL GAS HEAT POWER
kW
2100
2600
3600
MINIMUM NATURAL GAS HEAT POWER
kW
400
450
500
¹) NATURAL GAS EMISSIONS
mg/kWh
Class 2
Class 2
Class 2
OPERATION
Two-stage progressive /
modulating
Two-stage progressive /
modulating
Two-stage progressive /
modulating
NATURAL GAS TRANSFORMER 50 Hz
26 kV 40 mA - 230 V
26 kV 40 mA - 230 V
26 kV 40 mA - 230 V
MAXIMUM NATURAL GAS HEAT RATE
Stm³/h
222
261.5
380.9
MINIMUM NATURAL GAS HEAT RATE
Stm³/h
40.3
45.3
52.9
MAXIMUM NATURAL GAS PRESSURE
hPa (mbar)
350
360
360
NATURAL GAS MINIMUM PRESSURE
hPa (mbar)
30
40
79
PROPANE GAS MAXIMUM THERMAL POWER
kW
2100
2600
3600
PROPANE GAS MINIMUM THERMAL POWER
kW
400
450
500
PROPANE GAS MAXIMUM HEAT CAPACITY
Stm³/h
85.9
106.38
147.2
PROPANE GAS MINIMUM HEAT CAPACITY
Stm³/h
16.4
18
20.4
PROPANE GAS MAXIMUM PRESSURE
hPa (mbar)
360
360
360
PROPANE GAS MINIMUM PRESSURE
hPa (mbar)
36.5
80
111
²)PROPANE EMISSIONS
mg/kWh
Class 2
Class 2
Class 2
50 Hz FAN MOTOR
kW
3
5.5
7
60Hz FAN MOTOR
kW
3.5
5.5
9
ABSORBED ELECTRICAL POWER* 50Hz
kW
3.7
6.5
8
ABSORBED ELECTRICAL POWER* 60Hz
kW
4.2
6.5
10.4
50 Hz POWER SUPPLY VOLTAGE
3N~ 400V ± 10%
3N~ 400V ± 10%
3N~ 400V ± 10%
DEGREE OF PROTECTION
IP54
IP54
IP54
FLAME DETECTOR
IONISATION PROBE
IONISATION PROBE
IONISATION PROBE
EQUIPMENT
LME 22..
LME 22..
LME 22..
AIRFLOW REGULATION
MECHANICAL CAM
MECHANICAL CAM
SOUND POWER***
dBA
WEIGHT WITH PACKING
kg
94
108
120
Calorific power lower than reference conditions 15° C, 1013 hPa (mbar):
Natural gas: Hi = 9.45 kWh/Stm³ = 34.02 MJ/Stm³
Propane gas: Hi = 24.44 kWh/Stm³ = 88.00 MJ/Stm³
For different types of gas and pressure values, please contact our sales department.
* Total absorption at start with ignition transformer on.
** The acoustic pressure measured with burner operating at maximum rated thermal output refers to the manufacturer's laboratory
environment conditions and cannot be compared to measurements carried out in different locations.
*** Acoustic power was obtained characterizing the manufacturer's laboratory with a sample source; this measurement has a class 2
accuracy (engineering class) with a standard deviation of 1.5 dB(A).
CO emissions, natural gas/propane ≤ 100 mg/kWh
¹) NATURAL GAS EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - natural gas
1
≤ 170
2
≤ 120
3
≤ 80
²) PROPANE EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - propane gas
1
≤ 230
2
≤ 180
3
≤ 140