Out2,3,4,5: 4A-AC1(2A-AC3)/ 250 VAC
Out1: 6A-AC1(3A-AC3)/ 250 VAC
Pt
A
B
GND
+12 VDC
0/1..5 V
0/2..10 V
+
(passive)
4..20
mA
+
INPUT
PTC
RS485
NO
G
4b
ANALOG.: 0/4..20mA - 0/2..10V
1b
TC
+
2b
3b
RELAYS:
OUTPUTS
SSR: 12 VDC/20 mA
6b
5b
1a
2a
4a
3a
+
+
NO
+
+
G
NC
C
+
C
NO
DIG. IN 2
DIG. IN 1
5a
6a
Out1
10b
220V
7b
9b
8b
Out2
12b
11b
7a
Out3
9a
8a
10a
12a
11a
Pt
100
1000
Cavo collegamento
Da K30 a TLK94
Baltur
Connettore
lato cavi
Connettore
lato cavi
Rosso
Marrone
Marrone
Rosso
Lato
K30
Lato
TLK 94
1
1
Cavo di collegamento con trasmettitore tipo K30 (cod
ice
CATTLB200--).
3 / 16
0006160005_201502
ENGLISH
The regulator is factory-set with input Pt1000 2 wires, PID regulation for heating. The regulation relays
are K1 and K2. (1, 2)
INITIAL PASSWORD 381
CONNECTION WIRING DIAGRAM
EXTERNAL TEMPERATURE OFFSET FUNCTION
This function allows user to change the selected set point according to the external temperature as
measured by a (duly programmed) K30 transmitter and re-transmitted in digital format (TTL)
to TLK94 controller.
This function relies on 2 parameters, Ad1 and Ad2, to define the extent of the offset at operation
range limits, i.e.:
Ad1 is the value to be added to selected set point when external temperature gets below zero.
Ad2 is the value to be added to selected set point when external temperature gets above zero.
Example
SP = 70 (with external temperature = 0 °C)
Ad1 = +10
Ad2 = -10
If external temperature is +20 °C (limit set for the transmitter) the boiler set point changes as follows:
[SP + (Ad2)] = [70 + (-10)] = 60 °C
If external temperature is -20 °C (limit set for the transmitter) the boiler set point changes as follows:
[SP + (Ad1)] = [70 + (10)] = 80 °C
NOTE:
1) The sum of set point + offset will be limited by SPLL and SPLH parameters
2) When transmitter detects a probe error or is not working or not present, TLK94 will use the local
set point.
Cavo collegamento
Da K30 a TLK94
Baltur
Connettore
lato cavi
Connettore
lato cavi
Rosso
Marrone
Marrone
Rosso
Lato
K30
Lato
TLK 94
1
1
Cavo di collegamento con trasmettitore tipo K30 (cod
ice
CATTLB200--).
Connection cable
from K30 to TLK94
Connection cable with K30-type transmitter (code CATTLB200--).
K30
side
TLK94
side
Cable-side connector
Cable-side connector
red
brown
Содержание LC3
Страница 2: ......
Страница 16: ...14 16 0006160005_201502 ITALIANO SCHEMA ELETTRICO DI COLLEGAMENTO LC3 E RWF40 A B C D ...
Страница 18: ...16 16 0006160005_201502 ITALIANO ...
Страница 32: ...14 16 0006160005_201502 ENGLISH CONNECTION WIRING DIAGRAM LC3 AND RWF40 A B C D ...
Страница 34: ...16 16 0006160005_201502 ENGLISH ...
Страница 48: ...14 16 0006160005_201502 ESPAÑOL ESQUEMA ELÉCTRICO DE CONEXIÓN LC3 Y RWF40 A B C D ...
Страница 50: ...16 16 0006160005_201502 ESPAÑOL ...
Страница 64: ...14 16 0006160005_201502 FRANÇAIS SCHÉMA ÉLECTRIQUE DE RACCORDEMENT LC3 ET RWF40 A B C D ...
Страница 66: ...16 16 0006160005_201502 FRANÇAIS ...
Страница 80: ...14 16 0006160005_201502 TÜRKÇE LC3 VE RFW40 ELEKTRİK BAĞLANTI ŞEMASI A B C D ...
Страница 82: ...16 16 0006160005_201502 TÜRKÇE ...
Страница 96: ...14 16 0006160005_201502 PYCCKИИ ЭЛЕКТРИЧЕСКАЯ СХЕМА СОЕДИНЕНИЯ ДЛЯ LC3 И RWF40 A B C D ...
Страница 98: ...16 16 0006160005_201502 PYCCKИИ ...
Страница 112: ...14 16 0006160005_201502 中 文 LC3 和 RWF40 的电气连接图 A B C D ...
Страница 114: ...16 16 0006160005_201502 中 文 ...
Страница 115: ......