14
7.1
Place and scheme of installation
7.1.1. The appliance must be installed in kitchens or any other heated non-residential premises according to the
project of gasification and set of rules SP 62.13330.2011.
7.1.2. The volume of the premise where the appliance is installed should be not less than 8 m
3
.
7.1.3. The premise where the water heater shall be installed must have good ventilation and constant fresh air
inflow (window or opening transom), because while the appliance is on, oxygen combustion occurs. Grids or gap in the
bottom part of the door or wall must not be tightly closed
7.1.4. The appliance must be connected to the exhaust flue with a good draught (rarefaction 1, 96…29, 4 Pа) and
besides it should be located as close to the exhaust flue as possible. One of the available ways to test the draught in the
exhaust flue is presented on the scheme 4.
No draught (the candle flame
Insufficient draught
Good draught
doesn’t’ bend) – do not use the
(the candle flame bends)
(the candle flame goes out)
appliance
do not use the appliance
-the appliance can be used
Scheme 4. Way of testing draught in the exhaust flue