LICHT UND LEUCHTEN
www.baltensweiler.ch
Tel. +41 41 429 00 30
BALTENSWEILER
EN
3 / 5
Premount the expansion plugs at a distance of 620 mm.
Check the load-bearing capacity of the fixture and, if necessary, adapt or
replace it to the respective ceiling construction.
Tighten the ceiling plate to the ceiling with screws.
Attach the cover to the mounting bracket (holds magnetically).
3
5
2
4
7
8
OyO D 3 and D 2 OyO XL
−
mounted luminaire heads:
Press the ball into the luminaire head by pushing it from the underside (LED)
to the topside with the thumb.
The lamp head can be supported on a padded base.
6
7a
7b
7c
9
Magnet must be attached to the rod.
4a
LED
6
On-site power supply cables may only be inserted into the luminaire with
double insulation . Insulate the power supply cables accordingly with the
enclosed insulation tubes. The insulation tubes must also be fixed in their
position with a cable tie.
With a lateral cable connection, a strain relief and a grommet must be provi-
ded (not part of the delivery).
Connect the power supply cable to the connection box N L
(functional earthing must be connected).
In the case of stranded cables, wire end sleeves must be used for the screw
contact in the connection box.
!
IMPORTANT! Read the instructions carefully beforehand and keep for future reference.
For safety regulations, protection classes and instructions, see page 5.
OyO D 2 / D 3
MOUNTING AND OPERATING INSTRUCTIONS
Mounting instructions
Disconnect the power supply during installation
(remove the fuse).
1
!
IMPORTANT! Read the instructions carefully beforehand and keep for future reference.
For safety regulations, protection classes and instructions, see page 5.
4b
7
8
9
DE
Remove the protective cap from the telescopic rod . Press the
rod into the ball as far as possible and fixate the grub screw
with the Allen key .
When the luminaire is completely installed, the power
supply may be switched on again
(switch on the fuse).
M 1203/32637/SaWa/20.05.2021
620 mm
Telescopic rod
LED
Ball
Luminaire head
6
Telescopic rod
Ceiling plate
Cover
Power supply cable
(double insulated)
Remove
protective cap
Luminaire heads
620 mm
8
3
2
4b
3
7c
2
7b
4a
620 mm
5
7a
1
9