Advanced Settings
Advanced Settings
The advanced menu for any SmartShunt allows the user to perform several
levels of reset of SmartLInk devices on the network. An explanation of each of
options is in the table below:
Menu Option
Description
RESTART DEV
RESTART DEVICE - Reboots the device (a Display
or SmartShunt) that is currently selected (shown
at the top of the screen).
RESET
NETWORK
RESET NETWORK - Resets the SmartLink
network. Learning, chemistry, faults etc. are all
retained.
FACTORY RST
FACTORY RESET - Performs a FULL reset of the
device. ALL history, including faults, chemistry,
capacity, learning etc. is reset. Performing a
Factory Reset on device does not perform a reset
on any other devices or SmartShunts on the
network. A Factory Reset should be performed
every time a battery bank is replaced.
XECHO (not
shown in
screenshot
above)
This performs a loopback test from the Display to
the device that is currently selected. It is useful
for testing the network connectivity between the
two devices. If you are getting errors, it typically
indicates a bad cable connection. (Note: While
you can run a test to the Bluetooth Gateway, it is
not a functional test and will give a false result.)
Performing a long press on any of the advanced settings immediately
performs that function, except for FACTORY RESET, which has a
confirmation step to help avoid false resets.
Specifications
Standard Configuration
1 Bank per SmartShunt Device
2 Start/Auxiliary Voltage Sense Lines
(Up to 32 Devices including Displays
and SmartShunts can be added to single
network.)
Supply Voltage Range
8-60V
MAX Bank Current-Monitored
Battery Size
1Ah-1310Ah
Average Supply Current
Display On: 20mA @ 12V
Sleep Mode: 10mA @ 12V
SmartShunt Operating
Temperature:
-40°C - +85°C (-40°F- +185°F)
SmartShunt Max Current @
24°C (75°F)
350A Continuous
600A for 10 minutes
Display Values
State of Charge (SoC%)
State of Health (SoH%)
Voltage (V)
Charge/Discharge Current (A)
Time Remaining (Hrs, Minutes)
History, Faults and Alerts
Communications Cable
4-wire, 22AWG, Shielded
4-pin Deutsch DT Style
Grounding
Negative Battery Connection
Standards Compliance
CE EMC Directive 2014/30/EU
RoHS 2 Directive 2011/65/EU