Programming For Short Or Long Display Mode
You can choose the amount of information displayed on the regulator. The information displayed on the short or long dis-
play is detailed on Page 7 of the manual. To adjust the regulator for short or long display:
TOUCH / HOLD when entry into the short/long display selector is indicated by dSP on the regulator’s LED.
1.
The regulator display will indicate codes Sd (for short display) or Ld (for long display).
2.
RELEASE when the display indicates your desired display mode. The display will cycle to dSP. You can re-activate to
3.
change your selection, or wait until the regulator cycles to the next programming mode.
INDICATES ENTRY INTO SHORT
OR LONG DISPLAY MODE
INDICATES END OF BASIC PROGRAMMING MODE
INDICATES SHORT
DISPLAY MODE
INDICATES LONG
DISPLAY MODE
dS
.
P
--
.
-
Sd
.
Programming For Alternator Failure Advisory Mode (BDL)
The regulator provides a ground signal on the dash lamp terminal when the following conditions occur: low battery volt-
age (<12.7V), high battery voltage (>15.5V), high battery temperature (>52
˚
C), or high alternator temperature (105
˚
C). In
addition, the user has the option to send the dash lamp to ground in the event that the stator output drops to zero volts.
The Regulator’s Default bdL setting is ON.
Monitoring stator output is an optional function which can be turned on or off
in the basic programming mode. The regulator’s default setting for the bdL mode is ON, meaning that the stator output is
being monitored. This function can be used in conjunction with a relay to control a charge indicator lamp.
To enable or disable the stator monitoring function, activate and hold when the bdL mode is indicated. Release when the
desired setting is shown. NOTE: Stator wire must be connected to the regulator’s Stator-In terminal to use this function.
Ld
.
INDICATES ENTRY INTO ALTERNA-
TOR FAILURE ADVISORY MODE
STATOR OUTPUT
MONITORING OFF
STATOR OUTPUT
MONITORING ON
bdL
OFF
On