background image

17

www.balmar.net   /   Customer Service: +1 (360) 435-6100 x1   /   Technical Support: +1 (360) 435-6100 x3

Tech Service is available Monday - Friday (8:30am - 7:30pm EST)

BATTERY EQUALIZATION

Due to the hazardous nature of equalization (the intentional overcharging of batteries to remove sulfation from the battery 

plates) we strongly recommend that the process be done at the dock with a voltage-adjustable shorepower charger. If it is 

absolutely impossible to do so, equalization can be done with the alternator and regulator by doing the following:

1. 

In Advanced programming, Pra, change the following values.

2. 

Cl to a voltage above the desired equalize voltage.

3. 

AHL to a voltage above the desired equalize voltage.

4. 

Bv to the desired equalize voltage.

5. 

Blc to the desired equalize time.

6. 

Disconnect ALL battery temperature sensors.

7. 

YOU MUST MONITOR THE BATTERIES DURING EQUALIZE PROCESS!

8. 

Once the equalization is complete, activate the regulator’s basic programming and reset the battery program 

mode to UFP, and allow the program to save. Once saved, access the basic programming mode again and reset 

for the desired battery program.

WARNING: EQUALIZATION IS A MANUAL PROCESS WITH POTENTIAL DANGERS.

DO NOT LEAVE SYSTEM UNATTENDED.

(F1c) Float Time. 

Controls minimum time in Float Mode before entering Calculated Float. Standard value set is .3 

hours (18 minutes). Settings are from 6 minutes to 6 hrs. Adjustable in .1 hrs (6 minute) increments.

(ALL) Low Voltage Limit.

 Allows user control of regulator’s low voltage limit. Spans between 10 volts and Fv. 

Dropping below ALL causes Dash Lamp to turn on. Default is 50.8 volts in .1 volt increments.

(FbA) Field Threshold - Bulk and Absorption.

 Controls the field output threshold required to cycle from Bulk 

to Absorb and Absorb to Float. Factory set at 65% of field output. Raising “FbA” shortens calculated bulk and 

absorption charge time. Adjusted in 1% increments. Span of adjustment is 16% to 96%. 

(FFL) Field Threshold - Float to Absorption. 

Controls the field output threshold required to cycle from float to 

absorption charging modes. Factory set at 65%. Raising “FFL” increases calculated float charge time. Adjusted in 

1% increments. Span of adjustment is 16% to 96%. 

(AL1) Alternator Temperature Threshold.

 Controls the 

Alternator over temperature set point. Requires MC-TS-A 

temperature sensor to be connected to the Alt. Temp. #1 and/or Alt. #2 temperature sensor terminals. Preset at 

100°C. Spans from 60-128°C. Adjustable in 1°C increments. 

(b1L) Battery Temperature Threshold.

 Controls the 

Battery over temperature set point. Requires MC-TS-B 

temperature sensor to be connected to the Bat. Temp. #1 and or Bat. #2 temperature sensor terminals. Preset at 

52°C. Spans from 42-56°C. Adjustable in 1°C increments.

(SLP) Slope Voltage Correction.

 Adjusts the voltage (in millivolts) the regulator uses when monitoring battery 

temperature sensing. Can be custom adjusted to meet the needs of unique battery technologies. Consult with 

battery manufacturer for specific slope voltage recommendations. Spans from 0 to 8.3 millivolts per degree Celsius. 

Default is 6.0 mV/°C. Adjustable in 0.1mV/°C increments. 

Содержание 96 Series

Страница 1: ...become entangled in your motor or other machinery prior to installing regulator and alternator 3 Wear ANSI approved safety eye wear and protective gear 4 DO NOT attempt to modify the regulator or alternator Modifications could result in damage to your charging system and will void your warranty 5 DO NOT attempt installation if you are tired or fatigued 6 Ensure that the engine has cooled before in...

Страница 2: ...s a rule of thumb the alternator should be rated at 25 40 of your house battery capacity depending on the battery chemistry 2 Ensure that the belt or belts driving the alternator are capable of handling the alternator s horsepower load 3 Only use the MC 620 regulator with 96 Series alternators and visa versa 4 96 Series alternators are NOT isolated ground they are case ground but provide an auxili...

Страница 3: ...inyurl com r8comkd ALTERNATOR OUTPUT TO BATTERY CAPACITY RATIO In order to achieve optimal performance from your charging system it is essential to determine the capacity your charging system is capable of supporting In general the size rating of the alternator should mirror the acceptance rate of the batteries being charged Differing battery technologies will vary in terms of their acceptance rat...

Страница 4: ...s stud provides a direct connection to the negative rectifier plate and can be used for best performance with a properly sized negative cable to the battery 3 External Field Wire BLUE Connects to MC 620 voltage regulator via wiring harness 4 Stator Output Wire WHITE Provides an unrectified source of AC voltage which can be used as a signal for an electric tachometer Contact the manufacture of the ...

Страница 5: ...he regulator is free from obstructions that restrict air movement around or below the regulator s aluminum heat sink While the regulator is designed to operate safely in conditions typical of a marine engine compartment the regulator may be better protected and easier to use and monitor if mounted outside of the engine compartment The max operating temperature is 90 C Should it be necessary to ins...

Страница 6: ... 1 LAMP 17 DASH LAMP MC 620 Regulator Terminal Layout Magnetic Reed Switch 17 16 15 14 13 12 11 10 9 8 7 6 5 1 2 3 4 1 Ground Input 2 12V Power Input 3 12V Ignition Input 4 Field Output 5 Alt Temp 6 Alt Temp 7 Bat 1 Temp 8 Bat 1 Temp 9 48V Battery Voltage Sensor 10 Data TX 11 Data RX 12 Stator In 13 Tach Out 14 Bat 2 Temp 15 Bat 2 Temp 16 Aux 1 Lamp 17 Dash Lamp 48V B B START 12V B L WARNING DO NO...

Страница 7: ...S A is required It is NOT included in the harness and must be purchased separately It allows your MC 620 voltage regulator to monitor your alternator temperatures and limit output if safe operating levels are exceeded The MC 620 uses active temperature regulation to maximize high temperature output The MC TS A sensor includes a 54 cable a sensing attachment lug and positive and negative regulator ...

Страница 8: ...re When an electric tachometer is used the alternator s stator output will provide the electrical pulse needed to drive the tachometer The MC 620 has been designed to provide regulated tach output when the WHITE stator wire is connected to the regulator s Stator In 12 terminal and the out feed wire to the electric tachometer is connected to the Tach Out terminal 13 terminal Not required for magnet...

Страница 9: ...e voltage source 2 Connect the negative terminal on the lamp or audible alert to the Dash Lamp terminal on the regulator 3 When connected the lamp should flash at regulator start up to indicate active status INITIAL PRE FLIGHT TEST AND START UP When the regulator is properly mounted and the regulator wiring is installed the MC 620 is ready for pre flight testing Before turning on the engine it s a...

Страница 10: ...voltage for a set time period specified by the battery program selected Factory set values are 55 6 volts for 0 3 hours 18 minutes and are adjustable with Av and A1c respectively See page 16 7 Calculated Absorption Charge Target voltage is maintained at the Absorption Charge level The regulator calculates battery condition by constantly monitoring field duty cycle battery sense voltage and an inte...

Страница 11: ...OO HOT OVER 55 C FACTORY DEFAULT E21 BATTERY 2 TOO HOT OVER 55 C FACTORY DEFAULT E22 ALTERNATOR TOO HOT OVER 107 C E24 VOLTAGE REGULATOR TOO HOT OVER 90 C E25 BATTERY 1 TOO COLD E33 BATTERY SENSE DIS CONECTED E41 FIELD VOLTAGE TOO HIGH E42 STATOR VOLTAGE TOO HIGH E51 SMALL ENGINE MODE IS IN OPERATION In addition to the information provided in the basic display shown above the MC 620 long display p...

Страница 12: ...hird display digits The RED light indicated activation of the reed switch Within the basic and advanced programming instructions activation of the reed switch will be described by the following actions TOUCH RELEASE Indicates the action of contacting and immediately removing the magnet from the reed switch TOUCH HOLD Indicates the action of contacting and holding the magnet to the reed switch BASI...

Страница 13: ... specifics Your battery manufacturer may supply you with a C rate for charging and discharging The maximum amount of charging current your battery can safely handle is determined by multiplying the C Rate by the capacity of the bank i e 4x 100Ah 12V batteries rated at 0 5C charge 400 Ah 0 5C 200amps MAX If your alternator is capable of outputting more current at any time or condition than the batt...

Страница 14: ...nager b 1 95 Field Max b 2 90 Field Max b 3 85 Field Max b 4 80 Field Max b 5 75 Field Max b 6 70 Field Max b 7 65 Field Max b 8 60 Field Max b 9 55 Field Max Sd Short Display Mode Ld Long Display Mode OFF Stator Output Monitoring OFF ON Stator Output Monitoring ON AP1 AP2 AP3 AP4 AP5 PrA Entering Advanced Programming Looped 3 Times Yes b 0 100 Field Max dLC Start Delay AHL High Voltage Limit CL C...

Страница 15: ... b 0 INDICATES BLM OFF b 1 INDICATES BLM SETTING 1 FIELD REDUCTION 5 b 2 INDICATES BLM SETTING 2 FIELD REDUCTION 10 b 3 INDICATES BLM SETTING 3 FIELD REDUCTION 15 b 4 INDICATES BLM SETTING 4 FIELD REDUCTION 20 b 5 INDICATES BLM SETTING 5 FIELD REDUCTION 25 b 6 INDICATES BLM SETTING 6 FIELD REDUCTION 30 b 7 INDICATES BLM SETTING 7 FIELD REDUCTION 35 b 8 INDICATES BLM SETTING 8 FIELD REDUCTION 40 b ...

Страница 16: ... scroll upward or downward To reverse the direction of scroll 1 REMOVE the magnet from the reed switch 2 Wait for the mode indicator to be displayed 3 TOUCH HOLD when the mode indicator is displayed The values for that mode will begin to scroll in the opposite direction Continue to HOLD until the desired value is displayed 4 REMOVE the magnet from the RED dot The mode indicator will be displayed a...

Страница 17: ...mit Allows user control of regulator s low voltage limit Spans between 10 volts and Fv Dropping below ALL causes Dash Lamp to turn on Default is 50 8 volts in 1 volt increments FbA Field Threshold Bulk and Absorption Controls the field output threshold required to cycle from Bulk to Absorb and Absorb to Float Factory set at 65 of field output Raising FbA shortens calculated bulk and absorption cha...

Страница 18: ...51 2V Adjustable with ALL See Page 12 High Battery Voltage 62V Adjustable with AHL See Page 11 High Alternator Temperature 225 F Adjustable with AL1 See Page 12 Requires installation of MC TS A sensor High Battery Temperature 125 F Adjustable with B1L See Page 12 Requires installation of MC TS B sensor Low Battery Temperature 32 F LiFePO4 only not adjustable Alternator Failure No voltage on stator...

Страница 19: ...the BLACK ground wire at the regulator as shown in diagram 1 With the ignition turned OFF check voltage on the RED power Voltage Sense Terminal 9 BLUE field and BROWN Ignition wires in the regulator plug Voltages should be as follows RED wire equal to start battery voltage for 12V battery Terminal 9 RED wire equal to battery voltage 48V BLUE wire zero volts BROWN wire zero volts 2 With the ignitio...

Страница 20: ...xt test Testing the actual output of the alternator is known as Full Field Testing This can be accomplished by jumping a positive 12VDC current to the field terminal at the rear of the alternator This test eliminates both the regulator and the harness making it easier to isolate your investigation to the alternator CAUTION Ensure that all voltage sensitive equipment is turned off prior to starting...

Страница 21: ...pplication maintenance or modification or b any misuse contrary to the instructions provided with the product or c loss or d malfunctions caused by other equipment or e acts of God Examples of conditions not warranted cracked or broken cases parts damaged by fire water freezing lightning collision theft explosion rust corrosion or items damaged in route to Balmar for repair Balmar s Warranty is vo...

Страница 22: ...22 www balmar net Customer Service 1 360 435 6100 x1 Technical Support 1 360 435 6100 x3 Tech Service is available Monday Friday 8 30am 7 30pm EST NOTES ...

Страница 23: ...23 www balmar net Customer Service 1 360 435 6100 x1 Technical Support 1 360 435 6100 x3 Tech Service is available Monday Friday 8 30am 7 30pm EST NOTES ...

Страница 24: ...world To Find a CDI distribution partner visit www cdielectronics com Both Balmar and CDI Products are manufactured in our ISO 9000 Certified Factory in Huntsville Alabama Please read carefully All policies procedures and instructions are subject to change This guide was prepared to provide information and does not constitute a contract Balmar reserves the right without prior notice to change dele...

Отзывы: