www.balluff.com
13
english
6.3
Calibration procedure overview
6.3.1 Teach-in
The factory set null point and end point is replaced by a
new null point and end point. The null point and end point
can be set separately, the output gradient changes.
The detailed procedure for teach-in is described
Steps
►
Move magnet to the new null position.
►
Read new null point by activating the programming
inputs.
⇒
The current end point remains the same.
New null point
Before
After
Fig. 6-2: Reading new null point
►
Move magnet to the new end position.
►
Read new end point by activating the programming
inputs.
⇒
The current null point remains the same.
6
Calibration procedure (continued)
New end point
Before
After
Fig. 6-3: Reading new end point
Inverting
►
The gradient of the output can be inverted by activating
the programming inputs.
⇒
For example, a rising output gradient is changed to
a falling gradient.
BTL7-A/E1 _ 0-M _ _ _ _ -K(8)-SA262-K _ _ /F _ _
Micropulse Transducer - Rod Style
Содержание MICROPULSE BTL7-A/E1 0-M Series
Страница 1: ...Betriebsanleitung deutsch BTL7 A E1_0 M_ _ _ _ K 8 SA262 K_ _ F_ _...
Страница 2: ...www balluff com...
Страница 25: ...User s Guide english BTL7 A E1_0 M_ _ _ _ K 8 SA262 K_ _ F_ _...
Страница 26: ...www balluff com...
Страница 49: ...Manual de instrucciones espa ol BTL7 A E1_0 M_ _ _ _ K 8 SA262 K_ _ F_ _...
Страница 50: ...www balluff com...
Страница 73: ...Notice d utilisation fran ais BTL7 A E1_0 M_ _ _ _ K 8 SA262 K_ _ F_ _...
Страница 74: ...www balluff com...
Страница 97: ...Manuale d uso italiano BTL7 A E1_0 M_ _ _ _ K 8 SA262 K_ _ F_ _...
Страница 98: ...www balluff com...