![Balluff Micropulse BTL5 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/balluff/micropulse-btl5-series/micropulse-btl5-series_technical-description-users-manual_3053831009.webp)
www.balluff.com • 1-800-543-8390
9
BTL5-_-M_-J-DEXC-TA12
Micropulse Linear Position Sensor
Analog & Digital-Pulse Outputs
Explosion-Proof Rod Style
4.2 Specifications
Specifications
Measur
ement T
ype
Linear Displacement
Measuring Range
51 mm (2 in.) to 4445 mm (175 in.)
Connection Means
Inter
nal scr
ew-type terminal block, Min. 26 A
WG/Max. 16 A
WG
Shock Rating
100 g/6 ms per IEC 68-2-27
V
ibration Rating
12 g, 10 to 200 Hz per IEC 68-2-6
Envir
onmental Pr
otection
IP68*
*T
o maintain the IP68 rating, ensur
e that the connection at the conduit opening also meets
this standar
d.
Thr
ead sealant should be used on the conduit opening to ensur
e pr
otection against moistur
e
ingr
ess.
Take car
e to pr
event the possibility of inter
nal condensation in the conduit fr
om entering the
position sensor housing.
Housing/Rod Material
Stainless steel, 316L
Cover Material
Stainless steel, 316L (Standar
d version)
Alter
native: 304 Stainless Steel or Nitr
onics 60 or Eur
opean equivalent (1.4404, 1.4571, 1.4305)
Cover O-Ring Material
V
iton
Pr
essur
e Rating, Rod
8700 psi (600 bar)
Standar
d Operating T
emperatur
e
Range
-40°C to +80°C (-40°F to +176°F) (Refer to Appr
ovals on page 5 for application specific
temperatur
e constraints.)
Low T
emperatur
e Operation
< -40°C (-40°F)
Pr
otection method rated to -50°C (-58°F). Sensor functionality not assur
ed.
Storage T
emperatur
e Range
-50°C to +85°C (-58°F to +185°F) (Refer to Appr
ovals on page 5 for application specific
temperatur
e constraints.)
Humidity
<90%, non-condensing
Electrical Performance Specifications
For complete electrical and performance specifications, r
efer to Micr
opulse BTL5
B/Z-housing User Guides for the appr
opriate output type.