Balluff Micropulse BTL5 Series Скачать руководство пользователя страница 5

www.balluff.com • 1-800-543-8390

5

BTL5-_-M_-J-DEXC-TA12 

Micropulse Linear Position Sensor 

Analog & Digital-Pulse Outputs 

Explosion-Proof Rod Style

1.3  Use and inspection

The relevant safety regulations must be followed when using the linear position sensor system. 
In particular, steps must be taken to ensure that should the linear position sensor system 
become defective, no hazards to persons or property can result. This includes the installation 
of additional safety limit switches, emergency shutoff switches and maintaining the permissible 
ambient conditions.

2.1  Functional Description

The Micropulse EX Linear Position Sensor is designed to provide highly accurate position 

feedback in areas containing potentially explosive gases and dusts.

The Micropulse EX Linear Position Sensor consists of:

• 

A heavy-duty stainless steel housing with a Modified 1/2"-14 NPT threaded conduit 
opening for cable entry. Modified threading in accordance with FM Standard 3615, 
Chapter 3.3.3, Paragraph D, Section 1. Manufacturer does not supply conduit.

• 

An internal electronics module/sensing element that provides electrical position feedback 
signals in the form of an analog voltage, analog current, or digital pulse signals. The 
internal electronics module/sensing element can be replaced while the external housing 
stays in place.

Approvals:

2  General Information 

CSA15.2411253X

Class I Zone 1 AEx db IIC T* Ga/Gb T6 Ta -50° to 65°C, T5 Ta -50° to 80°C
Class I Zone 1 Ex db IIC T* Gb T6 Ta -50° to 65°C, T5 Ta -50° to 80°C
Class I, Division 1, Groups A,B,C,D
Class II, Division 1, Groups E,F,G; 
Class III T6 Ta -50° to 65°C, T5 Ta -50° to 80°C Type 4X/6P; IP68
SIRA 11ATEX1104X
IECEx SIR 11.0048X

 II 1/2GD 

Ex db IIC T* Ga/Gb Ta -50° to 65°C (T6) -50° to 80°C (T5)
Ex t IIIC T85/T100°C Da IP68 Ta -50° to 65°C (T85) -50° to 80°C (T100)

  2813  

 (manufactured in the USA) 

  0102  

 (manufactured in Hungary)

Содержание Micropulse BTL5 Series

Страница 1: ...BTL5 _ M_ J DEXC TA12 Micropulse Linear Position Sensor Analog Digital Pulse Outputs Explosion Proof Flame Proof Rod Style Technical Description User s Guide...

Страница 2: ...00 4 4 Severity level 3 Surge EN 61000 4 5 Severity level 2 Line induced noise induced by high frequency fields EN 61000 4 6 Severity level 3 Magnetic fields EN 61000 4 8 Severity level 4 i Preface AT...

Страница 3: ...the applicable code of practice e g EN 60079 17 5 Repair of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice e g EN 60079 19 6 Inst...

Страница 4: ...d be installed by qualified personnel and used in accordance with the conditions for which it was designed Any unauthorized modification could result in equipment damage or personal injury and is expr...

Страница 5: ...less steel housing with a Modified 1 2 14 NPT threaded conduit opening for cable entry Modified threading in accordance with FM Standard 3615 Chapter 3 3 3 Paragraph D Section 1 Manufacturer does not...

Страница 6: ...nics Module Retaining Screws 8 Housing Screws M6x45 A4 70 Socket Head Cap Screws 6x included Replacement Screw Kit BTL7 A FK01 E J DEX 9 Float Magnet For use in liquid level applications See section 5...

Страница 7: ...EXC TA12 Micropulse Linear Position Sensor Analog Digital Pulse Outputs Explosion Proof Rod Style 1 2 5 6 8 16 17 7 1 Order code forcomplete linear position sensor assembly 2 Type 3 Serial number 4 Pr...

Страница 8: ...Style 4 1 Dimensions Mounting is accomplished using six M6x45 A4 stainless socket head cap screws supplied with linear position sensor or six 1 4 20x1 3 4 socket head cap screws user supplied 4 Mechan...

Страница 9: ...l condensation in the conduit from entering the position sensor housing Housing Rod Material Stainless steel 316L Cover Material Stainless steel 316L Standard version Alternative 304 Stainless Steel o...

Страница 10: ...Part number BTL P 1013 4R BTL P 1013 4S BTL P 1012 4R Material Aluminum Aluminum Aluminum Weight 12 g 12 g 12 g Order code BAM011T Part number BTL A AD09 M 00 EX Material Nickel Plated Brass Approvals...

Страница 11: ...er BTL2 S 5113 4K EX BTL2 6216 8P EX Material Stainless 316 Stainless 316 Weight 26 g 41 g Minimum fluid density 0 7 g cm3 0 6 g cm3 Immersion depth in 1 g cm3 H20 26 mm 41 mm Immersion depth in 0 7 g...

Страница 12: ...ke range per the instructions in section 6 5 otherwise proceed to next step Step 5 Replace the housing cover and tighten to 25 ft lbs minimum 30 ft lbs maximum Tighten secondary retaining screw ATEX 6...

Страница 13: ...in Profibus T 1 RxD TxD N 2 RxD TxD P 3 Data GND 4 Pwr Supply GND 5 Pwr Supply 6 VP 5V Output 7 Not used 8 Not used Output Type Order Code Fig 3 Pin Quadrature Q CANbus H 1 Output Channel A CAN GND 2...

Страница 14: ...lectronics module waveguide assembly out of the pressure housing Avoid bending the waveguide assembly Fig 6 Step 6 Carefully slide the new electronics module into the pressure housing Avoid bending th...

Страница 15: ...are configuration 1 1 position and 1 velocity 2 2 position and 2 velocity Baud rate 0 1 Mbaud 1 800 kbaud 2 500 kbaud 3 250 kbaud 4 125 kbaud 5 100 kbaud 6 50 kbaud 7 20 kbaud 8 10 kbaud Standard nomi...

Страница 16: ...x 859 727 4823 Web www balluff us E Mail balluff balluff com Canada Balluff Canada Inc 2840 Argentia Road Unit 1 Mississauga Ontario L5N 8G4 Phone 905 816 1494 Toll free 1 800 927 9654 Fax 905 816 141...

Отзывы: