3.3. Environmental and operating conditions
262
204
80
82
Fig. 3.2: Overall dimensions of the 3D stereo camera in millimeters
CAD models of the 3D stereo camera can be downloaded from
on the corre-
sponding product page. The CAD models are provided as-is, with no guarantee of correctness.
3.3 Environmental and operating conditions
The 3D stereo camera is designed for industrial applications. Always respect the storage, transport, and
operating environmental conditions outlined in
Table 3.4: Environmental conditions
3D stereo camera
Storage/Transport temperature
-20 °C to 60 °C
Operating temperature
0 °C to 45 °C (passive cooling)
Relative humidity (non condensing)
20 % to 80 %
Protection class
IP54
Others
• Free from corrosive liquids or gases
• Free from explosive liquids or gases
• Free from powerful electromagnetic interference
The 3D stereo camera is designed for an operating temperature (surrounding environment) of 0 °C to 45 °C
and relies on convective (passive) cooling. Unobstructed airflow, especially around the cooling fins, needs
to be ensured during use. The 3D stereo camera should only be mounted using the provided mechanical
mounting interface, and all parts of the housing must remain uncovered. A free space of at least 10 cm
extending in all directions from the housing, and sufficient air exchange with the environment is required to
ensure adequate cooling. Cooling fins must be free of dirt and other contamination.
MATRIX VISION GmbH
Manual: BVS 3D-RV1
14
Rev: 1.0
Status: Nov 14, 2022
Содержание MATRIX VISION BVS 3D-RV1
Страница 2: ...www matrix vision com ...
Страница 3: ...MATRIX VISION GmbH November 2022 BVS 3D RV1 3D Stereokamera MONTAGE UND BETRIEBSANLEITUNG ...
Страница 32: ......
Страница 33: ...MATRIX VISION GmbH November 2022 BVS 3D RV1 3D Stereo Camera ASSEMBLY AND OPERATING MANUAL ...
Страница 63: ......