Installation
The product must be installed such that it is protected
from electromagnetic fields and mechanical damage.
4.1.1 Quasi-flush mountable sensors
Quasi-flush mount sensors require a space behind the
active surface which is free of conductive materials. The
minimum permissible distance between the active surface
and installation material is designated
dimension X
(see
Fig. 4-1).
For ferroelectric installation materials (such as iron, steel
and stainless steel) dimension X is 2.5 mm. With non-
electrically conductive installation materials (such as brass
and aluminum), the distance is 2 mm.
The deviation in the effective operating distance associated
with the installation is maximum 10%.
Fig. 4-1:
Quasi-flush
installation
4.1.2 Non-flush mountable sensors
Non-flush mountable sensors require a clear space behind
the active surface (see Fig. 4-2).
Fig. 4-2:
Non-flush
installation
4
Installation and connection
4.2
Electrical connection
Fig. 4-3:
3
1
4
2
Pin assignments (pin side view)
Pin Signal
1
+ (operating voltage UB+)
2
DIO (Teach-in input (DI) / switching output (DO))
3
GND (operating voltage UB-; reference potential)
4
C/Q (IO-Link communication (C) / switching output
(Q))
Tab. 4-1: Plug connector pin assignment
Fig. 4-4:
1
4
2
3
+
C/Q
DIO
–
Connection diagram
BES M12M_1-YIC_0_-S04G