7
APPENDIX
39
www. matrix-vision.com
BVS SC-_1280Z00-70-000
SMART
CAMERA
IO
www.balluff.com
) of
the smart cam-
era is not dis-
solved because
of a WiFi con-
nection
Please
1. turn off the WiFi module and
2. reboot the laptop.
Now, you can check, if the camera was resolved using the Windows shell:
1. Click on the Windows start button and
2. enter
cmd
.
3. Enter
nbtstat -c
.
All resolved NetBIOS names will be listed and you should find the smart camera
there:
C:\Users\war>nbtstat -c
Ethernet:
Node IpAddress: [0.0.0.0] Scope Id: []
No names
in
cache
Local Area Connection:
Node IpAddress: [169.254.93.40] Scope Id: []
NetBIOS Remote Cache Name Ta-
ble
Name Type Host Ad-
dress Life [sec]
-------------------------------------------
-----------------
SC-NNNNNNNNNDE <20> UNIQUE
169.254.4.9 540
SC-NNNNNNNNNDE <00> UNIQUE
169.254.4.9 549
You can also reach the camera with the IP address directly (in this sample
169,254.4.9).
Connection to
the camera pos-
sible, however a
dialog appears,
that the connec-
tion to the cam-
era was lost
Firewall active
Please add
http://gemini-*
as trusted web addresses to your firewall settings.
Action menu
"Monitor": No
fluent display or
freeze of the
browser
Display device is
too weak
Deactivate the live image diplay:
1. Change to the action menu "Configuration".
2. Select the Tool "Get image".
3. Deactivate the checkbox "outImage" in the result table.
4. Repeat this step for every used "Get image" and "Find object" tool.
Not every in-
spection result is
transferred to the
FTP server.
Connection to
the FTP server is
too slow.
Possible approaches:
1. Export only reports without images.
Содержание BVS SC Series