background image

259

www.balluff.com

BVS HS-Q Series
Standard Hand Held Barcode Reader

6

Appendix A: Technical Specifications

6.2

Standard Cable 
Pinouts

Standard Cable Pinouts: Handheld

Standard Cable Pinouts: Base Station an

Table Standard 

Cable Pinouts — Handheld (BVS HS QC … model) or Base Station Side

 provide standard pinout 

information for the interface cable.

Figure 1:

Standard Cable Pinouts: Handheld

Figure 2:

Standard Cable Pinouts: Base Station

The signal descriptions in 

Table Standard Cable Pinouts — Handheld (BVS HS QC … model) or 

Base Station Side

 apply to the connector on the reader and are for reference only. 

Pin 10

Cable Clip (Latch)

To Host

Cable

Cable Strain Relief

Bottom of Scanner

Interface Cable Port

Pin 1

4

5

7

6

3

1

2

8

Содержание BVS HS-Q Series

Страница 1: ...Balluff BVS HS Q Family Standard Handheld Barcode Reader Operation Manual english...

Страница 2: ...ument especially the Safety Notes section must be strictly observed This operator s manual must be carefully stored so that it is always available The information and illustrations in this operating m...

Страница 3: ...em and Network Layouts 25 Stand Alone Layout 25 Connecting the Base when Security Pin is Enabled 25 Linking the Reader to a Base Station 26 RF Devices 26 BT Models only 26 Linking a BT Reader to a PC...

Страница 4: ...cter 02 49 Intercode Delay 49 Caps Lock State 50 Numlock 50 USB Keyboard Speed 51 USB Keyboard Numeric Keypad 52 USB OEM Interface 53 USB OEM Device Usage 54 USB Interface Options 54 Transmit Labels i...

Страница 5: ...mbologies 88 Code EAN UPC 89 Coupon Control 89 UPC A 90 UPC A Enable Disable 90 UPC A Check Character Transmission 90 Expand UPC A to EAN 13 91 UPC A Number System Character Transmission 91 UPC A 2D C...

Страница 6: ...e Disable 118 Expand Code 128 to Code 39 118 Code 128 Check Character Transmission 118 Code 128 Function Character Transmission 119 Code 128 Quiet Zones 119 Code 128 Length Control 120 Code 128 Set Le...

Страница 7: ...isable 151 Code 11 Check Character Calculation 151 Code 11 Check Character Transmission 152 Code 11 Length Control 152 Code 11 Set Length 1 153 GS1 DataBar Omnidirectional 155 GS1 DataBar Omnidirectio...

Страница 8: ...ta Matrix Length Control 187 Data Matrix Set Length 1 187 Data Matrix Set Length 2 188 Maxicode 189 Maxicode Enable Disable 189 Maxicode Primary Message Transmission 189 Maxicode Length Control 190 Ma...

Страница 9: ...rity Features 219 BT Security Mode 219 BT PIN Code 219 Select PIN Code Length 220 Set PIN Code 220 Other BT Features 221 BT Poll Rate 221 Power Off 221 Powerdown Timeout 222 References 223 RS 232 Para...

Страница 10: ...cations 261 Error Codes 262 Base Station Indications Cordless Models ONLY 263 Base Station Button Indicators 263 Appendix B Standard Defaults 264 Appendix C Sample Barcodes 276 1D Barcodes 276 GS1 Dat...

Страница 11: ...n system design data base design algorithms technology technical data or information implementation techniques and trade secrets related to the Software b any other trade secrets marked appropriately...

Страница 12: ...third party licensors to any person other than End User s authorized employees or agents who are under confidentiality agreement and End User shall not use the Proprietary Information other than in c...

Страница 13: ...ALINGS BETWEEN THE PARTIES WHETHER ORAL OR WRITTEN EXCEPT AS SET FORTH IN A FUTURE WRITING SIGNED BY BOTH PARTIES 8 Limitation Of Liability IN NO EVENT SHALL BALLUFF S LIABILITY FOR DAMAGES IF ANY WHE...

Страница 14: ...nditions 11 4 It is agreed that a place of jurisdiction for legal actions falling within the jurisdiction as regards the subject matter of the Amtsgericht local courts shall be the Amtsgericht Stuttga...

Страница 15: ...ppendix B Standard Defaults references common factory default settings for reader features and options Appendix C Appendix C Sample Barcodes offers sample barcodes for several common symbol ogies Appe...

Страница 16: ...rm The family of BVS HS Q Series handheld area consists out of several models BVS HS QC SDR MA 01 01 Cable version with USB cable in a kit BVS HS QB SDR MA 02 02 Bluetooth version with basestation and...

Страница 17: ...eated in the cradle it will sound a chirp to indicate that the cradle has detected the reader connection The LEDs on the base will indicate the status of the battery LED STATUS Power on Data Yellow On...

Страница 18: ...ot expose the battery pack to liquids or allow the battery to get wet Do not apply voltages to the battery pack contacts WARNING In the event the battery pack leaks and the fluid gets into your eye do...

Страница 19: ...European Directive 2006 66 EC 2011 65 EU 2002 96 EC and 2012 19 EU and subsequent modifica tions US and China regulatory and others laws and regulations about the environment 2 7 Replacing the Batter...

Страница 20: ...ocess 1 Insert the top of the new pack inside the reader s handle 2 Rotate the battery pack downward while pressing the bottom side of the battery pack to seat securely into the contacts springs so th...

Страница 21: ...Selection and set the desired interface 3 Configure Interface Settings only if not using factory settings for that interface 4 Go to Configuring Other Features if modifications are needed from factory...

Страница 22: ...ure 4 USB Connection Connect the reader to a USB port on the terminal PC using the correct USB cable for the inter face type you ordered Reference Figure USB connection Figure 5 USB connection Other c...

Страница 23: ...eeding Connect the interface cable before applying power to the Base Station 3 4 2 Base Station Connection and Routing 1 Remove the rubber Cable Stopper from the bottom of the Base Station 2 Securely...

Страница 24: ...e plugged in reinsert the rubber Cable Stopper 4 Connect to an AC Adapter and plug the AC power cord into the wall outlet Figure 7 Connecting the Base Station Cable Stopper P C I F Cable Cable Stopper...

Страница 25: ...th the cable facing downwards as shown in Figure Connecting to the Host to prevent undue strain on the socket 3 4 3 System and Network Layouts Stand Alone Layout 3 4 4 Connecting the Base when Securit...

Страница 26: ...s after this tone indi cate a security error 3 4 6 Linking a BT Reader to a PC The reader can optionally be linked to a Bluetooth enabled PC with the serial port profile in either server mode or clien...

Страница 27: ...n the programming barcode from this section which selects the appropriate interface type matching the system the reader will be connected to Next proceed to the corresponding section in this manual al...

Страница 28: ...m Interfaces on page 37 Keyboard Settings on page 45 RS 232 FEATURES RS 232 standard interface Select RS232 STD Set RS 232 Interface Features starting on page 29 Select RS232 WN RS 232 Wincor Nixdorf...

Страница 29: ...ettings allow you to enable disable symbologies set label lengths require check digit etc 3 6 4 Software Version Transmission The software version of the device can be transmitted over the RS 232 and...

Страница 30: ...of this manual The programming items listed in the following sections show the factory default settings for each of the menu commands CAUTION Reading either of the Restore Factory Configuration comma...

Страница 31: ...Reading Parameters on page 69 control various operating modes and indicators status functioning Symbology specific parameters 1D Symbologies on page 87 provides configuration of a personalized mix of...

Страница 32: ...y or ignore host commands When set to ignore the reader will ignore all host commands except for those necessary for service mode flash programming mode keeping the interface active transmission of la...

Страница 33: ...32 and USB interfaces are available in the next section RS 232 USB Com Inter faces on page 37 Reference Appendix B The most common configuration settings are listed in the Default column of the table...

Страница 34: ...Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Baud Rate See page 224 for information on this feature Baud Rate 1200 Baud Rate 2400 Baud Rate 4800 Baud Rate 9600 Baud Rate 19 200 Ba...

Страница 35: ...e reader to interface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data Stop Bits Set the number of stop bits to match host device requirements See page 224 for mor...

Страница 36: ...pe accord ing to host device requirements See page 224 for more information Handshaking Control See page 224 for more information about this feature Parity None Parity Even Parity Odd DEFAULT CR2 CR2...

Страница 37: ...rovided for feature descriptions and programming barcodes for each parameter A column has also been provided for recording of your preferred default settings for these same configurable features for a...

Страница 38: ...to gain a user s attention to an illegal entry or other important event Intercharacter Delay No Delay Select Intercharacter Delay Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE...

Страница 39: ...mmand ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 226 for more information Beep On Not On File Disable Beep On Not On File Enable NF...

Страница 40: ...s or any hex value from 0 to 0xFF can be selected See page 227 for more information Setting to previously defined characters such as XON XOFF or host commands conflicts with normal operation of these...

Страница 41: ...for more information on setting this feature Select ACK NAK Timeout Value Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the...

Страница 42: ...he host Select ACK NAK Retry Count Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphanumeric characters...

Страница 43: ...to disable the reader ASCII characters or any hex value from 0 to 0xFF can be selected See page 230 for more information on setting this feature Indicate Transmission Failure Disable Indication Indica...

Страница 44: ...racters or any hex value from 0 to 0xFF can be selected See page 231 in References for more information on setting this feature Setting to previously defined characters such as XON XOFF or host com ma...

Страница 45: ...ovided for feature descriptions and programming bar codes for each parameter A column has also been provided for recording of your preferred default settings for these same configurable features for a...

Страница 46: ...ported Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces listed i...

Страница 47: ...Mode French Canadian Country Mode Germany Supports only the interfaces listed in the Coun try Mode feature description Country Mode Hungary Country Mode Italy Supports only the interfaces listed in th...

Страница 48: ...isted in the Coun try Mode feature description Country Mode Portugal Country Mode Romania Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces liste...

Страница 49: ...0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table see Microsoft Windows Codepage 1252 on page 293 Intercode Delay Specifies the delay between labels transmitted to the host...

Страница 50: ...encoding keyboard is selected Numlock This option specifies the setting of the NUMLOCK key Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Страница 51: ...ng Barcodes USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard This feature applies ONLY to the USB Keyboard interface USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyb...

Страница 52: ...sing Barcodes USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad USB Keyboard Speed 7ms USB Keyboard Speed 8ms USB Keybo...

Страница 53: ...configure for the USB OEM interface Other USB interfaces are included in the appropriate chapter for their host type Reference The most common configuration settings are listed in the Default column o...

Страница 54: ...ay need to change this setting to enable all devices to communicate Options are Table Top Reader Handheld Reader USB Interface Options This feature provides for an interface specific control mechanism...

Страница 55: ...re IBM Standard Format Send labels in standard IBM format Mixed IBM Standard and Code 39 Format Code 39 Format Translate the following symbologies to Code 39 USB OEM Code128 Code 93 and Codabar Interf...

Страница 56: ...page 233 for more detailed instructions on setting these features Global Prefix Suffix on page 57 Global AIM ID on page 58 Label ID on page 60 Label ID Pre Loaded Sets on page 61 Individually Set Labe...

Страница 57: ...EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix barcode fol lowed by the digits in hex from the Alphanumeric characters in Ap...

Страница 58: ...lowed by A code character see some samples in the table below followed by A modifier character the modifier character is symbol dependent AIM IDs This feature enables disables addition of AIM IDs for...

Страница 59: ...E 45 EAN13 P5 E 45 EAN13 COMPOSITE E 45 EAN8 E 45 EAN8 P2 E 45 EAN8 P5 E 45 EAN8 COMPOSITE E 45 FOLLET 2OF5 X 58 I2OF5 I 49 IATA INDUSTRIAL 2OF5 X 58 INDUSTRIAL 2OF5 X 58 ISBN X 58 ISBT128 CONCAT X 58...

Страница 60: ...or following the transmitted barcode data depending upon how this option is enabled This feature provides options for configuring custom Label IDs or individually per symbology see Individually Set La...

Страница 61: ...llowed by up to 3 characters from the ASCII Chart at the back of this manual See Label ID Set Individually Per Symbology on page 238 for detailed instructions on setting this feature Label ID Control...

Страница 62: ...exit Programming Mode Set ABC Codabar Label ID Character s Set Code 32 Pharmacode Label ID Charac ter s Set Anker Plessey Label ID Character s Set Code 93 Label ID Character s Set Australian Postal C...

Страница 63: ...et GS1 128 Label ID Character s Set EAN 8 P2 Label ID Character s Set GS1 128 Composite Label ID Character s Set EAN 8 P5 Label ID Character s Set GSI DataBar Limited Label ID Character s Set Follett...

Страница 64: ...er s Set MSI Label ID Character s Set Industrial 2 of 5 Label ID Character s Set Planet Postal Code Label ID Character s Set Interleaved 2 of 5 Label ID Character s Set Plessey Label ID Character s Se...

Страница 65: ...s Set Royal Postal Code Label ID Character s Set UPC A P2 Label ID Character s Set Standard 2 of 5 Label ID Character s Set UPC A P5 Label ID Character s Set Swedish Postal Code Label ID Character s...

Страница 66: ...D Symbologies Set Aztec Label ID Character s Set Maxicode Label ID Character s Set China Sensible Label ID Character s Set PDF 417 Label ID Character s Set Data Matrix Label ID Character s Set Micro P...

Страница 67: ...ripts Please contact our TecSupport for further information Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case Case conversion affects ONLY...

Страница 68: ...ASCII values The first character in the pair is the character that will be converted The second character in the pair is the character to convert to If the character to convert in a pair is FF then no...

Страница 69: ...Features on page 76 Scan Mode on page 76 Stand Mode Indication on page 77 Stand Operation on page 77 Pick Mode on page 78 Stand Mode Sensitivity on page 78 Stand Mode Illumination Off Time on page 79...

Страница 70: ...he unit reads a label and sees the same label again within the specified timeout the second read is ignored Double Read Timeout does not apply to scan modes that require a trigger pull for each label...

Страница 71: ...to Indicate This feature specifies when the reader will provide indication beep and or flash its green LED upon successfully reading a barcode Double Read Timeout 0 9 Second Double Read Timeout 1 Seco...

Страница 72: ...mono or bitonal beep sound Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the beeper s pitch tone Go...

Страница 73: ...ep Length Good Read Beep Length 60 msec Good Read Beep Length 80 msec Good Read Beep Length 100 msec Good Read Beep Length 120 msec Good Read Beep Length 140 msec Good Read Beep Length 160 msec Good R...

Страница 74: ...Configuration Using Barcodes Good Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels Good Read Beep Volume Beeper Off Good Read Beep Vol...

Страница 75: ...for setting this feature Good Read LED Duration Setting Keep LED on until next trigger pull Select Good Read LED Duration Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode...

Страница 76: ...cts the reader s scan operating mode See page 243 in References for descriptions Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode...

Страница 77: ...to switch to Stand Mode or when inserted into the special Stand support which automatically enables the Stand Mode 2 The reader is placed into the cradle of the base station cordless models only Belo...

Страница 78: ...the reader to accurately target labels when they are placed close together such as on a pick sheet Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and hi...

Страница 79: ...ce the state is entered The range for this setting is from 1 to 255 seconds in 1 second increments See page 245 in References for further description of this feature Select Stand Mode Time Setting To...

Страница 80: ...ing this feature Stand Illumination Control OFF Stand Illumination Control ON Stand Illumination Control Dim Select Flash ON Time Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE...

Страница 81: ...r all symbologies Select Flash OFF Time Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphanumeric chara...

Страница 82: ...ion of this feature Aiming Off After Decoding Set Aiming Duration Timer To configure scan the ENTER EXIT PRO GRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphan...

Страница 83: ...beam after a good read Mobile Phone Mode This mode is useful for reading barcodes displayed on a mobile phone Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec Green Sp...

Страница 84: ...n the Disable barcode below to return the reader to its default for this feature To set decoding for only 2D codes go to 2D Normal Inverse Symbol Control on page 179 Partial Label Reading Control Disa...

Страница 85: ...ntered is decoded and sent When Multiple Reading Mode is enabled the reader keeps on processing the image until all the labels present are decoded The reader then sorts the data from all the barcodes...

Страница 86: ...ode length when Multiple Labels per Frame is enabled Select Symbologies for Multiple Labels Ordering To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at le...

Страница 87: ...s 2 Scan the correct barcode to set the desired programming feature or parameter You may need to cover unused barcodes on the page and possibly the facing page to ensure that the reader reads only the...

Страница 88: ...an the ENTER EXIT PROGRAMMING Mode barcode 2 Scan the Disable All Symbologies barcode 3 Complete the programming sequence by reading the ENTER EXIT PROGRAMMING barcode Additional information about man...

Страница 89: ...ng Barcodes Code EAN UPC Coupon Control This feature is used to control the reader s method of processing coupon labels Coupon Control Allow all coupon barcodes to be decoded Coupon Control Enable onl...

Страница 90: ...logy UPC A Enable Disable When disabled the reader will not read UPC A barcodes UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A barcode data UPC...

Страница 91: ...cting this feature also changes the symbol ogy ID to match those required for EAN 13 UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system ch...

Страница 92: ...el component be decoded when a base label of this symbology is decoded UPC E The following options apply to the UPC E symbology UPC E Enable Disable When disabled the reader will not read UPC E barcod...

Страница 93: ...g with UPC E barcode data UPC E 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded UPC E Check Character Tran...

Страница 94: ...E data to the EAN 13 data format Selecting this feature also changes the symbol ogy ID to match those required for EAN 13 Expand UPC E to UPC A Expands UPC E data to the UPC A data format UPC E to EAN...

Страница 95: ...This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format UPC E Number System Character Do not transmit UPC E Number System Character T...

Страница 96: ...ogy EAN 13 Enable Disable When disabled the reader will not read EAN 13 JAN 13 barcodes EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode...

Страница 97: ...N13 Flag1 character The Flag 1 character is the first character of the label EAN 13 ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Bookland labels starting with 978 to ISBN l...

Страница 98: ...decoded when a base label of this symbology is decoded ISSN The following options apply to the ISSN symbology ISSN Enable Disable Enables disables conversion of EAN JAN13 Bookland labels starting with...

Страница 99: ...an 8 symbology EAN 8 Enable Disable When disabled the reader will not read EAN 8 JAN 8 barcodes EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 b...

Страница 100: ...to EAN 13 JAN 13 EAN 8 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded Expand EAN 8 to EAN 13 Disable Expa...

Страница 101: ...affects all of these unless otherwise marked for each feature description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits Price Weigh...

Страница 102: ...cifies the number of quiet zones for UPC EAN labels Quiet zones are blank areas at the ends of a barcode typically 10 times the width of the narrowest bar or space in the label The property applies to...

Страница 103: ...n are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded with out an add on the base label will be transmitted without an add on Condi tional add on set...

Страница 104: ...his option sets the time the reader will look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 106 Optional Add on Ti...

Страница 105: ...Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Optional Add on Timer 60ms Optional Add on Timer 70ms Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 14...

Страница 106: ...t after reading the linear EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 104 Optional GS1 128 Add On Timer Disable Optional GS1 128 Add On Timer 10ms...

Страница 107: ...onfiguration Using Barcodes Optional GS1 128 Add On Timer 60ms Optional GS1 128 Add On Timer 70ms Optional GS1 128 Add On Timer 100ms Optional GS1 128 Add On Timer 120ms Optional GS1 128 Add On Timer...

Страница 108: ...nal GS1 128 Add On Timer 180ms Optional GS1 128 Add On Timer 200ms Optional GS1 128 Add On Timer 220ms Optional GS1 128 Add On Timer 240ms Optional GS1 128 Add On Timer 260ms Optional GS1 128 Add On T...

Страница 109: ...optional Code 39 check character When disabled any check character in the label is treated as a data character Code 39 Disable Code 39 Enable Code 39 Check Character Calculation Don t Calculate Code...

Страница 110: ...e disable transmission of Code 39 start and stop characters Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters Code 39 Check Character Transmiss...

Страница 111: ...r space in the label Code 39 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a min...

Страница 112: ...50 characters Table Code 39 Length 1 Setting Examples provides examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 39 Length 1 Setting Examples STEP ACTIO...

Страница 113: ...ot include start stop characters Table Code 39 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Code 39 Length 2 Setting...

Страница 114: ...y to the Code 32 Italian Pharmaceutical Code symbology Code 32 Enable Disable When disabled the reader will not read Code 32 barcodes Code 32 Feature Setting Exceptions Trioptic Code Disable Trioptic...

Страница 115: ...r along with Code 32 barcode data Code 32 Start Stop Character Transmission This option enables disables transmission of Code 32 start and stop characters Code 32 Check Character Transmission Don t Se...

Страница 116: ...39 CIP Enable Disable Enables Disables ability of the reader to decode Code 39 CIP labels Code 39 Danish PPT The following options apply to the Code 39 Danish PPT symbology Code 39 Danish PPT Enable...

Страница 117: ...39 LaPoste Enable Disable Enables disables the ability of the reader to decode Code39 La Poste labels Code 39 PZN The following options apply to the Code 39 PZN symbology Code 39 PZN Enable Disable E...

Страница 118: ...ode 39 This feature enables disables expansion of Code 128 labels to Code 39 labels Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode...

Страница 119: ...uiet Zones This feature specifies the number of quiet zones for Code 128 labels Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space...

Страница 120: ...ation Using Barcodes Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology See page 231 for more information Code 128 Lengt...

Страница 121: ...80 characters Table Code 128 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 128 Length 1 Setting Examples STE...

Страница 122: ...s to ignore this length only one fixed length Table Code 128 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Code 128 Le...

Страница 123: ...GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels GS1 128 2D Component This feature enables...

Страница 124: ...option to enable disable ISBT128 concatenation of 2 labels ISBT 128 Force Concatenation When enabled this feature forces concatenation for ISBT ISBN 128 Concatenation Disable ISBN 128 Concatenation En...

Страница 125: ...ation Using Barcodes ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic This option is only valid when ISBT 128 Concatenation is enabled see ISBT 128 Concatenation...

Страница 126: ...128 Dynamic Concatenation Mode ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatena...

Страница 127: ...xit Programming Mode 4 Configuration Using Barcodes Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2...

Страница 128: ...2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calculation Check German Parcel I 2 of 5 Check Character Calculation...

Страница 129: ...Length Control on page 129 Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode The length includes the barcode s check and data characters...

Страница 130: ...this appendix to enter numbers as you would select digits characters from a keypad 0 and 2 0 and 6 1 and 4 5 AND 0 6 Scan ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake S...

Страница 131: ...s length only one fixed length Table I 2 of 5 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature I 2 of 5 Length 2 Setting...

Страница 132: ...P HR Enable Disable Enables Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels Follett 2 of 5 The following options apply to the Follett 2 of 5 symbology Follett 2 of 5 Enable Disab...

Страница 133: ...Disable When disabled the reader will not read Standard 2 of 5 barcodes Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Standard 2...

Страница 134: ...either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed l...

Страница 135: ...charac ters Table Standard 2 of 5 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 if you want detailed instructions on setting this feature Standard 2 of 5 Length 1...

Страница 136: ...length only one fixed length Table Standard 2 of 5 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Standard 2 of 5 Lengt...

Страница 137: ...Disable Enables Disables ability of reader to decode Industrial 2 of 5 labels Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 o...

Страница 138: ...r variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed leng...

Страница 139: ...cters Table Industrial 2 of 5 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 if you want detailed instructions on setting this feature Industrial 2 of 5 Length 1 Se...

Страница 140: ...ers A setting of 0 specifies to ignore this length only one fixed length Table Industrial 2 of 5 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions...

Страница 141: ...ogy IATA Enable Disable Enables Disables the ability of the reader to decode IATA labels IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of...

Страница 142: ...haracter Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label is treated as a data char...

Страница 143: ...along with Codabar barcode data Codabar Start Stop Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters Codabar Check Character Transmission D...

Страница 144: ...characters Codabar Start Stop Character Match When enabled this option requires that start and stop characters match Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar...

Страница 145: ...pace in the label Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimu...

Страница 146: ...cter The length can be set from 3 to 50 characters Table Codabar Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Co...

Страница 147: ...from 3 to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table Codabar Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed i...

Страница 148: ...C Codabar symbology ABC Codabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynami...

Страница 149: ...second ticks used by the ABC Codabar Dynamic Concatenation Mode ABC Codabar Dynamic Concatenation Time out 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec ABC Codabar Dynamic Concatenation...

Страница 150: ...ader Enter Exit Programming Mode 4 Configuration Using Barcodes ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated ABC Codabar Force Concatenation Disable ABC C...

Страница 151: ...ot read Code 11 barcodes Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character Code 11 Disable Code 11 Enable Code 11 Check...

Страница 152: ...ecifies either variable length decoding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed l...

Страница 153: ...harac ters Table Code 11 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 11 Length 1 Setting Examples STEP ACT...

Страница 154: ...re this length only one fixed length Table Code 11 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Code 11 Length 2 Sett...

Страница 155: ...nable Disable When disabled the reader will not read GS1 DataBar Omnidirectional barcodes GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be transl...

Страница 156: ...directional 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded GS1 DataBar Omnidirectional 2D Compo nent Disa...

Страница 157: ...DataBar Expanded Enable Disable When disabled the reader will not read GS1 DataBar Expanded barcodes GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translate...

Страница 158: ...tion Using Barcodes GS1 DataBar Expanded 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded GS1 DataBar Expand...

Страница 159: ...pecifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed...

Страница 160: ...Table GS1 DataBar Expanded Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature GS1 DataBar Expanded Length 1 Setting E...

Страница 161: ...nore this length only one fixed length Table GS1 DataBar Expanded Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature GS1 Da...

Страница 162: ...r Limited Enable Disable When disabled the reader will not read GS1 DataBar Limited barcodes GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the G...

Страница 163: ...ponent be decoded when a base label of this symbology is decoded Code 93 The following options apply to the Code 93 symbology Code 93 Enable Disable Enables Disables ability of reader to decode Code 9...

Страница 164: ...ter Transmission Enables disables transmission of an optional Code 93 check character Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93 Check Chara...

Страница 165: ...This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Len...

Страница 166: ...acters Table Code 93 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 93 Length 1 Setting Examples STEP ACTION...

Страница 167: ...om 1 to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table CODE 93 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed inst...

Страница 168: ...Enables disables quiet zones for Code 93 MSI The following options apply to the MSI symbology MSI Enable Disable Enables Disables ability of reader to decode MSI labels Code 93 Quiet Zones Quiet Zone...

Страница 169: ...haracter MSI Check Character Transmission Enables disables transmission of an MSI check character MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 MSI Check Charact...

Страница 170: ...feature specifies either variable length decoding or fixed length decoding for the MSI symbol ogy Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For...

Страница 171: ...om 01 to 50 characters Table MSI Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature MSI Length 1 Setting Examples STEP...

Страница 172: ...to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table MSI Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions...

Страница 173: ...ter Calculation Enables Disables calculation and verification of an optional Plessey check character Plessey Disable Plessey Enable Plessey Check Character Calculation Disable Plessey Check Character...

Страница 174: ...es either variable length decoding or fixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length...

Страница 175: ...01 to 50 characters Table Plessey Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Plessey Length 1 Setting Examples...

Страница 176: ...0 characters A setting of 0 specifies to ignore this length only one fixed length Table Plessey Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions...

Страница 177: ...stem To set most features 1 Scan the ENTER EXIT PROGRAMMING barcode at the top of applicable programming pages 2 Scan the correct barcode to set the desired programming feature or parameter You may ne...

Страница 178: ...software will spend attempting to decode a 2D label The selectable range is 10 milliseconds to 2 55 milliseconds 2D Maximum Decoding Time 100 msec 2D Maximum Decoding Time 200 msec 2D Maximum Decoding...

Страница 179: ...e for decoding normal negative printed 2D symbols This configura tion item applies globally to all the 2D symbologies that support that feature according to Stan dard AIM Specification Data Matrix QR...

Страница 180: ...ngth 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 3 832 characters in increments of 0001 pad with zeroe...

Страница 181: ...and Held Barcode Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginni...

Страница 182: ...oes See page 232 for detailed instructions on setting this feature Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at l...

Страница 183: ...ode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be s...

Страница 184: ...See page 232 for detailed instructions on setting this feature Select China Sensible Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcod...

Страница 185: ...pad with zeroes See page 232 for detailed instructions on setting this feature Select China Sensible Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above...

Страница 186: ...x with different form factors Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configured as a bit mask to filter one or more Data Matrix...

Страница 187: ...h Mode Characters can be set from 0001 to 3 116 characters in increments of 0001 pad with zeroes See page 232 for detailed instructions on setting this feature Data Matrix Length Control Variable Leng...

Страница 188: ...oes See page 232 for detailed instructions on setting this feature Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at...

Страница 189: ...ables disables ability of reader to decode Maxicode labels Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Secondary Message is not readabl...

Страница 190: ...Characters can be set from 0001 to 0145 characters in increments of 0001 pad with zeroes See page 232 for detailed instructions on setting this feature Maxicode Length Control Variable Length Maxicode...

Страница 191: ...ith zeroes See page 232 for detailed instructions on setting this feature Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode...

Страница 192: ...th Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed...

Страница 193: ...value greater than 2 710 will be considered to be 2 710 See page 232 for detailed instructions on setting this feature Select PDF417 Length 1 Setting To configure this feature scan the ENTER EXIT PRO...

Страница 194: ...with zeroes in increments of 01 Any value greater than 2 710 will be considered to be 2 710 See page 232 for detailed instructions on setting this feature Select PDF417 Length 2 Setting To configure t...

Страница 195: ...7 Code 128 GS1 128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM ID and label type Code 128 EAN128 AIM Id and...

Страница 196: ...can be set from 0001 to 0366 characters pad with zeroes in increments of 01 Any value greater than 0366 will be con sidered to be 0366 See page 232 for detailed instructions on setting this feature M...

Страница 197: ...1 Any value greater than 0366 will be con sidered to be 0366 See page 232 for detailed instructions on setting this feature Select Micro PDF417 Length 2 Setting To configure this feature scan the ENTE...

Страница 198: ...gth Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixe...

Страница 199: ...es See page 232 for detailed instructions on setting this feature Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left...

Страница 200: ...s See page 232 for detailed instructions on setting this feature Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left f...

Страница 201: ...Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be...

Страница 202: ...e page 232 for detailed instructions on setting this feature Select Micro QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left...

Страница 203: ...pad with zeroes See page 232 for detailed instructions on setting this feature Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the bar...

Страница 204: ...des 4 9 11UCC Composite UCC Composite Enable Disable Enables disables the ability of the reader to decode the stacked part of a UCC Composite label This feature is not effective when Global AIM IDs ar...

Страница 205: ...l wait for the stacked part of a UCC Composite label before transmitting the linear label without an add on UCC Optional Composite Timer Timer Disabled UCC Optional Composite Timer 100msec UCC Optiona...

Страница 206: ...st Kix Portugal Post Postal Code Selection Disable All Postal Codes Postal Code Selection Enable Postnet Postal Code Selection Enable Planet Postal Code Selection Enable Royal Mail Postal Code Selecti...

Страница 207: ...d Barcode Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Postnet BB Control Controls the ability of the reader to decode B and B fields of Postnet labels Postnet BB Control Disable...

Страница 208: ...sion Beep on page 209 Beep Frequency on page 209 Beep Duration on page 210 Beep Volume on page 211 Disconnect Beep on page 211 Docking Beep on page 212 Leash Alarm on page 212 Configuration Updates st...

Страница 209: ...sables the Good Transmission Beep indication When enabled a beep occurs when a Label is correctly transmitted to the base Beep Frequency Adjusts radio specific beep indications to sound at a low mediu...

Страница 210: ...ure controls the duration of radio specific beep indications Beep Duration 60 msec Beep Duration 80 msec Beep Duration 100 msec Beep Duration 120 msec Beep Duration 140 msec Beep Duration 160 msec Bee...

Страница 211: ...ic beep indications There are three select able volume levels Disconnect Beep Enables disables the beep indication that a handheld has become connected or disconnected from a Base Station Beep Volume...

Страница 212: ...nces where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader must be linked to the Base Station If the reader is asleep or disconnected from the...

Страница 213: ...ies Standard Hand Held Barcode Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Leash Alarm 5 Seconds Leash Alarm 10 Seconds Leash Alarm 25 Seconds Leash Alarm 30 Seconds CBTLB05 CR C...

Страница 214: ...method when the Auto Configuration Update feature is disabled and you want a one time config uration update to be performed on the reader Copy Configuration to Base Station Scan the following label to...

Страница 215: ...the handheld goes out of range and is disconnected from the remote device Manual The handheld will always store labels to Flash memory The user must manually send the stored labels to the remote devic...

Страница 216: ...delay in 10 msec increments between transmitting labels stored in batch memory Do not scan an ENTER EXIT PROGRAMMING MODE label in conjunction with this barcode RF Batch Mode Transmit Delay No Delay...

Страница 217: ...data inclusion Source Radio Address Transmission Enables disables the ability of source radio address information to be transmitted to the host and if so at what position with respect to the label da...

Страница 218: ...rcode at left followed by the digits from the Alphanumeric characters in Appendix 18 Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad rep resentin...

Страница 219: ...d examples for this feature BT Security Mode This feature enables disables authentication and encryption of the BT link Use the feature BT PIN Code on page 219 to specify the length and digits in the...

Страница 220: ...e Set 4 character BT PIN Code To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphanumeric characters in Appendix...

Страница 221: ...rcodes Other BT Features BT Poll Rate This feature specifies the time between BT polls Power Off See Power Off on page 27 for information about this BT feature BT Poll Rate Maximum BT Poll Rate BT Pol...

Страница 222: ...re sets the time for automatically switching the unit off when the imager has been idle Powerdown Timeout Disable Powerdown Timeout 10 minutes Powerdown Timeout 20 minutes Powerdown Timeout 30 minutes...

Страница 223: ...a Editing starting on page 233 Global Prefix Suffix on page 234 Global AIM ID on page 235 Label ID on page 236 Character Conversion on page 241 Reading Parameters starting on page 242 Good Read LED Du...

Страница 224: ...er Select the parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an o...

Страница 225: ...odes in this appendix to enter numbers as you would select digits characters from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion aft...

Страница 226: ...MODE to enter Programming Mode 4 Scan the barcode SELECT ACK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in Appendix 18 Use the barcodes in this appendix to en...

Страница 227: ...a key pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This...

Страница 228: ...ppendix to enter numbers as you would select digits characters from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last ch...

Страница 229: ...its characters from a keypad that repre sent the number which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar...

Страница 230: ...from a key pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode...

Страница 231: ...ication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This completes the procedure See Table Enable Character Setting Examples for some examples of how to set this feature En...

Страница 232: ...riable Length For variable length decoding a minimum and maximum length may be set on page 231 Mode or the second fixed length if in Fixed Length For fixed length decoding two different lengths may be...

Страница 233: ...le output for advanced users Factory default settings for data editing is typically set to NONE A prefix or suffix may be applied only to a specified symbology reference 1D Code Selection starting on...

Страница 234: ...de back cover of this manual to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 barcodes from Ap...

Страница 235: ...haracter see the table below followed by A modifier character the modifier character is symbol dependent Figure 3 AIM ID This feature enables disables addition of AIM IDs for all symbology types SYMBO...

Страница 236: ...changing from one Label ID set to another all other reader configuration settings including the host interface type will be erased and set to the stan dard factory defaults Any custom configuration o...

Страница 237: ...2OF5 CIP HR e IATA INDUSTRIAL 2OF5 IA 494100 260000 INDUSTRIAL 2OF5 W 570000 W 570000 ISBN I 490000 400000 ISBT128 CONCAT f 660000 f 660000 ISSN n 6E0000 n 6E0000 MATRIX 2OF5 g MAXICODE MC 4D4300 x 78...

Страница 238: ...iated hex characters as 3D Turn to Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad starting on page 281 and scan the barcodes representing the h...

Страница 239: ...239 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader 5 References Figure 4 Label ID Position Options OR Prefix Suffix Label ID Label ID Bar Code Data Aim ID...

Страница 240: ...Bar Omnidirec tional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the inside back cover then scan in these digits characters...

Страница 241: ...ld look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 char acters Nothing is done with the last two charac...

Страница 242: ...ppendix 18 Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad representing the duration which was determined in the steps above You will hear a two...

Страница 243: ...ous reading is activated until Reading Active Time on page 245 has elapsed or the trigger has been released and pulled again Double Read Timeout on page 70 prevents undesired multiple reads of the sam...

Страница 244: ...om the keypad in Appendix 18 Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad that repre sent the setting which was determined in the steps above...

Страница 245: ...s from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exi...

Страница 246: ...a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Progr...

Страница 247: ...ou would select digits characters from a keypad representing the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PRO...

Страница 248: ...ct digits characters from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING...

Страница 249: ...barcode SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING 5 Scan the appropriate two alphanumeric characters from the keypad in Appendix 18 Use the barcodes in this appendix to enter numbers as you woul...

Страница 250: ...S1 DataBar_LIM_ID 0A EAN128 34 GS1 DataBar_LIM_COMP 0B C128_PROGRAMMING_LA BEL 35 GS1 DataBar_Omnidirectional_ COMP 0C CODE128 36 GS1 DataBar_EXP_COMP 0D FNC3_C128_LABEL 37 GENERIC_DATA 0E DATA MATRIX...

Страница 251: ...ransferred and updated in a linked base station 1B EAN85 46 FOLLETT_2OF5 1C Reserved 47 Reserved 1D EAN132 48 Reserved 1E EAN135 49 CODE39_CIP 1F EAN138 4A ABC_CODABAR 20 ISBN_ID 4B I2OF5_CIP 21 TWO_L...

Страница 252: ...ix to enter numbers as you would select digits characters from a keypad that repre sent the hexadecimal characters which were determined in the steps above You will hear a two beep indication after th...

Страница 253: ...g the hexadecimal entries determined in the steps above You will hear a two beep indication after the last character 7 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode Figure 5 BT...

Страница 254: ...0mA N A Idle standby typical 50mA N A Battery Type N A Li Ion battery pack Typical charge time for full charge from full dis charge N A 6 hours with Host Power through the micro USB cable connection N...

Страница 255: ...to 40cm EAN 7 5mil 0 15cm 13mil 0 5 35cm PDF 417 6 6mil 1 0 130cm 10mil 0 21cm 15mil 0 5 24cm Data Matrix 10mil 1 0 13 cm 15mil 0 18cm QR Code 10mil 0 5 13cm 15mil 0 18cm Minimum Element Width Standa...

Страница 256: ...417 QR Code Aztec Data Matrix Inverse Data Matrix Data Matrix is configurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 characters Maxicode QR Code...

Страница 257: ...re 40 to 70 C Humidity Operating 0 to 95 relative humidity non condensing Drop Specifications Reader withstands 18 drops from 1 5 meters 5 0 feet to concrete Ambient Light Immunity Up to 86 000 Lux Co...

Страница 258: ...on your prod uct for actual details as they may vary from those depicted Radio Features CAUTION The BVS HS Q series Handheld Reader is not user serviceable Opening the case of the unit can cause inte...

Страница 259: ...odel or Base Station Side provide standard pinout information for the interface cable Figure 1 Standard Cable Pinouts Handheld Figure 2 Standard Cable Pinouts Base Station The signal descriptions in T...

Страница 260: ...nd Held Barcode Reader 6 Appendix A Technical Specifications Standard Cable Pinouts Handheld BVS HS QC model or Base Station Side Pin RS 232 OEM USB 1 RTS out 2 D 3 D 4 GND GND GND 5 RX 6 TX 7 VCC VCC...

Страница 261: ...to Indicate on page 71 The reader will beep once at cur rent frequency volume mono bi tonal setting and duration upon a successful label scan ROM Failure There is an error in the reader s software pr...

Страница 262: ...of Label A label has been rejected N A Reader sounds three times at lowest frequency current volume Label Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be readed...

Страница 263: ...00mSec Programming Mode Yellow LED blinks quickly Configuration alignment with the handheld is in progress Red LED blinks quickly Battery charging in progress Red LED on Battery charging complete Gree...

Страница 264: ...ONLY Baud Rate on page 34 9600 34 Data Bits on page 35 8 Data Bits 35 Stop Bits on page 35 1 Stop Bit 35 Parity on page 36 None 36 Handshaking Control on page 36 RTS 36 RS 232 USB COM Intercharacter D...

Страница 265: ...cate on page 71 After Decode 71 Good Read Beep Type on page 72 Mono 72 Good Read Beep Frequency on page 72 High 72 Good Read Beep Length on page 73 80 ms 73 Good Read Beep Volume on page 74 High 74 Go...

Страница 266: ...e EAN UPC Coupon Control on page 89 Enable only UPCA coupon decoding 89 UPC A UPC A Enable Disable on page 90 Enable 90 UPC A Check Character Transmission on page 90 Send 90 Expand UPC A to EAN 13 on...

Страница 267: ...able 100 EAN 8 2D Component on page 100 2D Component Not Required 100 UPC EAN Global Settings UPC EAN Price Weight Check on page 101 Disable 101 UPC EAN Quiet Zones on page 102 Two Modules 102 Add Ons...

Страница 268: ...Special Codes Code 39 Danish PPT Enable Disable on page 116 Disable 116 Code 39 LaPoste Enable Disable on page 117 Disable 117 Code 39 PZN Enable Disable on page 117 Disable 117 Code 128 Code 128 Ena...

Страница 269: ...page 129 Variable 129 I 2 of 5 Set Length 1 on page 129 6 129 I 2 of 5 Set Length 2 on page 131 50 131 Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable Disable on page 132 Disable 132 Folle...

Страница 270: ...142 Don t Calculate 142 Codabar Check Character Transmission on page 143 Send 143 Codabar Start Stop Character Transmis sion on page 143 Transmit 143 Codabar Start Stop Character Set on page 144 abcd...

Страница 271: ...page 156 2D component not required 156 GS1 DataBar Expanded GS1 DataBar Expanded Enable Dis able on page 157 Disable 157 GS1 DataBar Expanded GS1 128 Emulation on page 157 Disable 157 GS1 DataBar Expa...

Страница 272: ...172 Plessey Plessey Enable Disable on page 173 Disable 173 Plessey Check Character Calculation on page 173 Enable Plessey std check char verifica tion 173 Plessey Check Character Transmission on page...

Страница 273: ...age 190 Variable 190 Maxicode Set Length 1 on page 190 1 190 Maxicode Set Length 2 on page 191 0145 191 PDF417 Enable Disable on page 192 Enable 192 PDF417 Length Control on page 192 Variable 192 PDF4...

Страница 274: ...ge 211 High 211 Disconnect Beep on page 211 Enable 211 Docking Beep on page 212 Enable 212 Leash Alarm on page 212 Disable 212 Automatic Configuration Update on page 214 Enable 214 Copy Configuration...

Страница 275: ...aults BT Security Mode on page 219 Disable 219 Select PIN Code Length on page 220 4 character BT PIN Code 220 Set PIN Code on page 220 31323334 Default Pin Code is 1234 220 BT Poll Rate on page 221 20...

Страница 276: ...Reader 8 Appendix C Sample Barcodes 8 Appendix C Sample Barcodes The sample barcodes in this appendix are typical representations for their symbology types 1D Barcodes UPC A EAN 13 978033029095 Code 3...

Страница 277: ...277 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader 8 Appendix C Sample Barcodes Codabar 13579 Code 93 Code 11 123456789...

Страница 278: ...odes GS1 DataBar RSS GS1 DataBar variants must be enabled to read the barcodes below see GS1 DataBar Omnidirectional on page 155 GS1 DataBar Expanded Stacked 10293847560192837465019283746029478 450366...

Страница 279: ...s Standard Hand Held Barcode Reader 8 Appendix C Sample Barcodes GS1 DataBar 14 GS1 DataBar Omnidirectional Truncated 55432198673467 GS1 DataBar Omnidirectional Stacked 90876523412674 GS1 DataBar Omni...

Страница 280: ...tandard Hand Held Barcode Reader 8 Appendix C Sample Barcodes 2D Barcodes Aztec Datamatrix China Sensible Code MaxiCode PDF 417 ABCabc Micro PDF 417 QR Code Micro QR Code 123456 UCC Composite Test Mes...

Страница 281: ...com BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad 9 Appendix D Keypad Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad 0 1...

Страница 282: ...282 BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad A B C D E F...

Страница 283: ...rom 00 to 0x1F are sent as control character Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE...

Страница 284: ...F 0x NULL C SOH C S A STX C S B ETX C S C EOT C S D ENQ C S E ACK C S F BEL C S G BS HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T N...

Страница 285: ...en Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keyp d Enter Ins Pg Up 1x Pg Dwn Hom e F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Sp...

Страница 286: ...A 0 93 A 0 94 A 0 95 6x A 0 96 A 0 97 A 0 98 A 0 99 A 1 00 A 1 01 A 1 02 A 1 03 A 1 04 A 1 05 A 1 06 A 1 07 A 1 08 A 1 09 A 1 10 A 1 11 7x A 1 12 A 1 13 A 1 14 A 1 15 A 1 16 A 1 17 A 1 18 A 1 19 A 1...

Страница 287: ...3 A 1 14 A 1 15 A 1 16 A 1 17 A 1 18 A 1 19 A 1 20 A 1 21 A 1 22 A 1 23 A 1 24 A 1 25 A 1 26 A 1 27 8x A 0 128 A 0 129 A 0 130 A 0 131 A 0 132 A 0 133 A 0 134 A 0 135 A 0 136 A 0 137 A 0 138 A 0 139 A...

Страница 288: ...C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Spac e 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a...

Страница 289: ...F C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _...

Страница 290: ...2 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keyp d Enter Ins Pg Up 1x Pg Dwn Hom e F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Spac e 3x 0 1 2 3 4 5 6 7 8...

Страница 291: ...BS C S H HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS...

Страница 292: ...X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keyp d Enter Ins Pg Up 1x Pg Dwn Hom e F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Spac e 3x 0 1 2 3 4 5 6 7 8 9...

Страница 293: ...VS HS Q Series Standard Hand Held Barcode Reader 10 4 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy com ponents of Microsoft...

Страница 294: ...0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I...

Страница 295: ...295 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader NOTES...

Страница 296: ...aries USA Balluff Inc 8125 Holton Drive Florence Kentucky 41042 0937 Phone 859 727 2200 1 800 543 8390 applications balluff com www balluff com World Headquarters Germany Balluff GmbH Schurwaldstra e...

Отзывы: