8
english
3
Construction and function (continued)
3.2
Function
The BTL7 transducer contains the waveguide which is
protected by an aluminum housing. A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic speed.
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is
converted by a coil into an electrical signal. The travel time
of the wave is used to calculate the position that is output
in antivalent form as synchronous serial data (SSI) on the
RS-422 interface. This is done with a high level of precision
and reproducibility within the measuring range indicated as
the nominal length.
In addition to the position output value, the following
functions can be selected (only BTL7-S510(B)-…):
– Differential position
– Velocity (with and without leading sign)
– Speed difference
3.3
LED display
Fig. 3-2:
LED 2
LED 1
BTL7 LED displays
LED 1
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Green
Synchronous operation
1)
Internal measurement is synchronous to SSI query.
Off
Asynchronous operation
1)
Internal measurement is asynchronous to SSI query.
Flashing
green
Programming mode
Only with BTL7-S510(B)-…
1)
Asynchronous operation is reached when the external sampling rate is
> f
A,max
or < 62.5 Hz (only with BTL7-S5_ _B-…), see the technical data on
Note on configuration
(only BTL7-S510(B)-…)
The entire function scope can only be
configured with the PC software “Micropulse
Configuration Tool”. To do this, the USB
communication box must be connected
When reading or writing data via the Micropulse
Configuration Tool, LED 2 flashes green to display
programming mode.
Behavior of LED 1 and the error value through the entire
range:
Fig. 3-3:
Pos
SSI
out
0
≈ 5 mm
2
21
LED
Null point
End point
Magnet
missing
Behavior of LED 1 and error value BTL7 ≥ 5 µm
For resolutions ≥ 5 µm, in the case of an error, bit 2
21
is
set. For resolutions < 5 µm, there is no error bit and the
value 0 is output.
BTL7-S5_ _(B) -M _ _ _ _ -P-S32/S115/S147/KA_ _/FA_ _
Transducer – Profile Style
Содержание BTL7-S5-M Series
Страница 1: ...Betriebsanleitung BTL7 S5_ _ B M_ _ _ _ P S32 S115 S147 KA_ _ FA_ _ deutsch...
Страница 2: ...www balluff com...
Страница 29: ...User s Guide BTL7 S5_ _ B M_ _ _ _ P S32 S115 S147 KA_ _ FA_ _ english...
Страница 30: ...www balluff com...
Страница 57: ...Manual de instrucciones BTL7 S5_ _ B M_ _ _ _ P S32 S115 S147 KA_ _ FA_ _ espa ol...
Страница 58: ...www balluff com...
Страница 85: ...Notice d utilisation BTL7 S5_ _ B M_ _ _ _ P S32 S115 S147 KA_ _ FA_ _ fran ais...
Страница 86: ...www balluff com...
Страница 113: ...Manuale d uso BTL7 S5_ _ B M_ _ _ _ P S32 S115 S147 KA_ _ FA_ _ italiano...
Страница 114: ...www balluff com...