BTL7-S5
_ _
(B)-M
_ _ _ _
-A/B/Y/Z(8)-SA360-KA
_ _
-ZA10
Micropulse Transducer - Rod Style
english
2
NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
►
The mounting surface of the transducer must make
full contact with the supporting surface.
►
The bore must be perfectly sealed (O-ring/flat seal).
Only use the proper nut for the mounting thread. Firmly
tighten the transducer with a maximum torque of 100 Nm.
If installing horizontally with nominal lengths > 500 mm, we
recommend tightening the rod at the end (only possible
with Ø 10.2 mm) or supporting it.
If installed in a hydraulic cylinder, the magnet should not
make contact with the rod. Minimum bore diameter in the
support piston:
Tube diameter
Bore diameter
10.2 mm
At least 13 mm
8 mm
At least 11 mm
Square flange
20
5
3
M12x1
Ø 13.3
+0.10 -0.00
14
20
Ø 3.2
The square flange is included in the scope of
delivery.
Installation in hydraulic cylinders
1.
Lead the M12 contact insert through the mounting hole
and out of the cylinder.
2.
Support the contact insert on the 8-mm open-end
wrench. Attach the square flange onto the M12 contact
insert and press it with force until the insert audibly
engages.
When mounted, the contact insert protrudes from the
bottom of the square flange by approx. 2 mm.
2
3.
Fasten the square flange to the hydraulic cylinder using
4 screws. When installed, the connector complies with
protection category IP67.
Square flange
M12 contact insert
Installation
Mounting hole
Top view
Hydraulic cylinder
8-mm open-end wrench