www.balluff.com
11
english
4.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-3.
Note the information on shielding and cable
S32
Pin
KA
Cable color
BTL7-… interface
-C508
-C509
-C512
-C513
-E508
-E509
-E512
-E513
1
YE yellow
0…20 mA
2)
0…20 mA
2)
20…0 mA
2)
20…0 mA
2)
4…20 mA
2)
4…20 mA
2)
20…4 mA
2)
20…4 mA
2)
2
GY gray
0 V
3
PK pink
0…10 V
3)
10…0 V
3)
0…10 V
3)
10…0 V
3)
0…10 V
3)
10…0 V
3)
0…10 V
3)
10…0 V
3)
4
RD red
La (communication line)
5
GN green
Not used
1)
6
BU blue
GND
4)
7
BN brown
10…30 V
8
WH white
Lb (communication line)
1)
Unassigned leads can be connected to the GND on the controller side but
not to the shield.
2)
Factory setting, can be freely configured with the PC software.
3)
Referred to as output 2 in PC software.
4)
Reference potential for supply voltage and EMC-GND.
Tab. 4-3: Pin assignment of connector S32/KA_ _
4
Installation and connection (continued)
Fig. 4-9: Pin assignment of S32 connector (view of connector pins of
transducer)
BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
Содержание BTL7-E508-M P-S32/KA Series
Страница 2: ...www balluff com...