7.1
Accuracy
The specifications are typical values for the
BTL7-A/C/E/G… at 24 V DC and room temperature, with
a nominal length of 500 mm in conjunction with the
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R or
BTL-P-1014-2R magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Voltage, typical
Current, typical
±10 µm
±5 µm
Sampling rate
Dependent on the nominal length
At nominal lengths of 25…1200 mm
At nominal lengths of 1201…5000 mm
At nominal lengths of 5001…7620 mm
2 ms
4 ms
5,7 ms
Non-linearity at
Nominal length ≤ 500 mm
Nominal lengths of 501…7620 mm
±200 µm
±0.04% FS
Temperature coefficient
1)
Voltage
Current
≤ 40 ppm/K
≤ 20 ppm/K
Max. detectable velocity
10 m/s
7.2
Ambient conditions
Ambient temperature
−40…+85°C
Ambient temperature for UL
(only BTL7-…-KA…)
≤ +80°C
Storage temperature
−40…+100°C
Relative humidity
< 90%, non-condensing
Rod pressure rating (when
installed in hydraulic cylinders)
For Ø 10.2 mm
– ≤ 2000 mm
– ≥ 2001 mm
≤ 600 bar
≤ 300 bar
For Ø 21 mm
≤ 250 bar
Shock rating
Continuous shock
per EN 60068-2-27
3), 4)
100 g/6 ms
100 g/2 ms
Vibration
5)
per EN 60068-2-6
3), 4)
12 g, 10…2000 Hz
Degree of protection per
IEC 60529
Connector S32/S135 (when
attached)
IP67
Cable
IP67
7.3
Supply voltage (external)
Voltage, stabilized
6)
10…30 V DC
Ripple
≤ 0.5 V
ss
Current draw (at 24 V DC)
≤ 150 mA per unit
Inrush current
≤ 500 mA
per unit
Reverse polarity protection
7)
Up to 36 V
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V AC
1)
Nominal length = 500 mm, magnet in the center of the measuring range
2)
For UL: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard
4)
Resonant frequencies excluded
5)
Nominal length > 2000 mm: use only under static conditions
6)
For UL: The BTL must be externally connected via a limited-energy circuit
as defined in UL 61010-1, a low-power source as defined in UL 60950-1,
or a class 2 power supply as defined in UL 1310 or UL 1585.
7)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
2)
7
Technical data
BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
Содержание BTL7-A50 Series
Страница 2: ...www balluff com...
Страница 4: ...www balluff com...
Страница 26: ...www balluff com...
Страница 48: ...www balluff com...
Страница 70: ...www balluff com...
Страница 92: ...www balluff com...
Страница 113: ......