Electrical connection
Pin
BTL6-U110-…-S4
1
L+ (18
…
30 V)
2
Not used
1)
3
L
-
(GND)
4
C/Q (communication line)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-2: Connection assignment BTL6-…-S4
Fig. 4-8:
1
2
3
4
Pin assignment of S4 (view from above on BTL),
4-pin M12 circular plug
4.5
Cable routing
Defined ground!
The BTL and the control cabinet must be at the
same ground potential.
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the BTL and strong, external magnetic fields.
Cable routing
Do not route the cable between the BTL, controller, and
power supply near high voltage cables (inductive stray noise
is possible).
The cable must be routed tension-free.
Inductive stray noise from AC harmonics (e.g. from phase
angle controls) are especially critical and the cable shield
offers very little protection against this.
Cable length
Max. cable length 20 m. Longer cables may be used if
their construction, shielding and routing prevent noise
interference.
4
Installation and connection (continued)
BTL6-U110-M _ _ _ _ -PF-S4
Magnetostrictive Linear Position Sensor – Profile Style
Содержание BTL6-U110-M****-PF-S4 series
Страница 2: ...www balluff com...
Страница 3: ...BTL6 U110 M_ _ _ _ PF S4 Betriebsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 24: ......
Страница 25: ...BTL6 U110 M_ _ _ _ PF S4 User s Guide english...
Страница 26: ...www balluff com...
Страница 46: ......
Страница 47: ...BTL6 U110 M_ _ _ _ PF S4 Notice d utilisation fran ais...
Страница 48: ...www balluff com...
Страница 68: ......
Страница 69: ...BTL6 U110 M_ _ _ _ PF S4 Manuale d uso italiano...
Страница 70: ...www balluff com...
Страница 90: ......
Страница 91: ...BTL6 U110 M_ _ _ _ PF S4 Manual de instrucciones espa ol...
Страница 92: ...www balluff com...