12
français
Interface IO-Link
Données de paramétrage
Index
hex
S
ubindex
hex
Object name
Access
Length
Value Range
Gra-
dient
Unit
Default
0x3C
0x01
SetPoint 1 = SP1
R/W
2 octets
Process Data
100%
0x3C
0x02
SetPoint 2 = rP1
R/W
2 octets
Process Data
0%
0x3E
0x01
SetPoint 1 = SP2
R/W
2 octets
Process Data
100%
0x3E
0x02
SetPoint 2 = rP2
R/W
2 octets
Process Data
0%
0x60
0x00
Password
W
4 octets
0000..9999
0
0xD0
0x00
Delay Switching Time 1
R/W
2 octets
0..500
0.1
sec
0
0xD1
0x00
Delay Back Switching Time 1
R/W
2 octets
0..500
0.1
sec
0
0xD2
0x00
Delay Switching Time 2
R/W
2 octets
0..500
0.1
sec
0
0xD3
0x00
Delay Back Switching Time 2
R/W
2 octets
0..500
0.1
sec
0
0xD5
0x00
Min Pressure Value
R
2 octets
Process Data
0xD6
0x00
Max Pressure Value
R
2 octets
Process Data
0xD7
0x00
Measure damping
R/W
2 octets
0…1000
in 10 ms steps
1
ms
0
Capteurs de pression avec IO-Link