www.balluff.com
4
english
BSI R11A0-XXR-CXP360-S75G
Capacitive uniaxial inclination sensor with Modbus interface
Enter values (holding register)
Example:
The offset is to be changed (see register table).
The function codes for writing and reading apply to all
holding registers.
Write
Read
Slave
ID
Function
Code
Adress Quantity Checksum
Slave
ID
Function
Code
Adress Quantity Checksum
1 byte
06 Read
134
0x1300
2 bytes
1 byte
03 Write
134
0x1300
2 bytes
Register table
Parameter
Register
address
Scale
factor
Default
value
16-bit
Value range
Unit
Rights
Remarks
Input register (actual value)
Inclination
0
100
0
0 to 36000
1/100°
R
Sensor
temperature
10
100
0
1/100 °C
R
Inclination with
indicator options,
bits 16-23
17
100
0
0 to 36000
1/100°
R
Rotation direction
reversal
(cw/ccw) and
indicator shift by
–180° (indicator
±180°)
Inclination with
indicator options,
bits 0-15
18
100
0
–18000 to +17999
1/100°
R
Holding register (parameter)
Number of
measurements for
mean value
formation
133
-
1
1 to 20
-
R/W
Change is effective
immediately
Offset with
deviation
of 0° position
134
100
0
0 to 36000
1/100°
R/W
Change is effective
immediately
Direction
of rotation
135
-
0
0 = cw
1 = ccw
-
R/W
Change is effective
immediately
Indicator range
136
-
0
0 = 0 to +359.99°
1 = –180 to +
179.99°
-
R/W
Change is effective
immediately
Modbus
node address
200
-
1
1 to 247
-
R/W
Change is effective
after reset.
Value is not
checked for a valid
value range.
Modbus baud rate
201
1/100
Bd
192
96, 192, 384, 576
-
R/W
Change is effective
after reset.
An invalid value is
corrected to 96
(9600 Bd)