26
english
Event Code Event Type
Description
Device Status
0x8C40
(35904)
Warning
Maintenance Required
–
Cleaning
►
Clean the front lens of the sensor or reflector.
1 – Maintenance-Required
0x8CD0
(36048)
Warning
Inclination alarm
►
Check installation.
1 – Maintenance-Required
0x8CD1
(36049)
Warning
Vibration alarm
►
Check machine.
0 – Device is operating properly.
0x8CFF
(36095)
Warning
Low signal quality level
►
Check alignment of sensor
►
Clean sensor
0 – Device is operating properly.
0x8D07
(36103)
Warning
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
0 – Device is operating properly.
0x8D08
(36104)
Warning
Speed value is below the limit.
0 – Device is operating properly.
0x8D09
(36105)
Warning
Speed value is above the limit.
0 – Device is operating properly.
0x8D0B
(36107)
Warning
Short circuit at pin 2
►
Check wiring.
2 – Out-of-Specification
0x8D0E
(36110)
Notification
The time has elapsed. This event reports the timeout
of the minimum value/maximum value/average
calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it
does not indicate the end of the calculation.
0 – Device is operating properly.
0x8D10
(36112)
Warning
Device Temperature Upper Warning
– The set upper
temperature warning threshold has been exceeded.
0 – Device is operating properly.
0x8D12
(36114)
Warning
The defined threshold of the device-internal humidity
was exceeded.
►
Check installation and ambient conditions.
1 – Maintenance-Required
0x8D13
(36115)
Warning
One or more extreme conditions present.
0 – Device is operating properly.
0x8D20
(36128)
Warning
Device Temperature Lower Warning
– The device
temperature has fallen below the set lower
temperature warning threshold.
0 – Device is operating properly.
0x8D22
(36130)
Warning
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
0 – Device is operating properly.
0x8D23
(36131)
Error
Write cycle limit reached – saving no longer ensured
– replacement recommended.
1 – Maintenance-Required
0x8D24
(36132)
Warning
Parameter write error – for information purposes
only.
0 – Device is operating properly.
0x8D25
(36133)
Error
Parameters not consistent – basic settings are used,
service required. Parameterization processes and
resets can no longer be performed.
4 – Failure
0x8DC0
(36288)
Notification
Teach-in Timeout
– The current teach-in process
took too long and was interrupted.
0 – Device is operating properly.
Tab. 3-4: Events – Overview
3
Overview of IO-Link Data and Functions (continued)
BOS R254K-UUI-LK10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LK10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LK10 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI LK10 S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 112: ......
Страница 113: ...BOS R254K UUI LK10 S4 Configuration Guide english...
Страница 114: ...www balluff com...