www.balluff.com
25
english
Command Value
Device Action
0x81 (129)
Application Reset
0x82 (130)
Restore Factory Settings
0xA5 (165)
Maintenance Reset
0xA6 (166)
Switching Counter Reset
– Resets counter value and flags.
0xA7 (167)
Statistics Reset
– Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg
– Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics operation completely.
0xAA (170)
Signal Speed Monitoring Reset
– Resets the speed value and flags.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving average calculation.
0xAF (175)
Start Device Discovery
0xC0 (192)
Set Reference Orientation
– Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.
0xE0 (224)
Teach Preset
– Sets the current measurement value to the value of
Measurement Preset
.
0xE3 (227)
Teach-in of 100% reference
Tab. 3-3: System Commands – Overview
3.6
Events
Event Code Event Type
Description
Device Status
0x1850
(6224)
Notification
Process data profile selection cannot be used –
default value is used.
0 – Device is operating properly.
0x1851
(6225)
Notification
Process Data Update Timeout – for information
purposes only
0 – Device is operating properly.
0x1852
(6226)
Warning
Multiple Process Data Update Timeout – for
information purposes only
0 – Device is operating properly.
0x1860
(6240)
Warning
Warning about service life of transmitter.
►
Replace sensor during next maintenance cycle.
1 – Maintenance-Required
0x4000
(16384)
Error
Temperature Fault – Overload
– The device is
operated outside of the device-specific temperature
limits. Risk of device damage.
4 – Failure
0x4210
(16912)
Warning
Device Temperature Overrun – Clear Heat Of Source
– Risk of device damage. The device is too hot.
►
Remove heat source, provide the device with
heat insulation if necessary.
2 – Out-of-Specification
0x4220
(16928)
Warning
Device Temperature Underrun – Insulate Device
–
Risk of device damage. The device is too cold.
►
Insulate the device.
2 – Out-of-Specification
0x5000
(20480)
Error
►
Device Hardware Fault – Device exchange
– The
sensor is damaged.
►
Replace sensor.
4 – Failure
0x5110
(20752)
Warning
Primary supply voltage exceeded
►
Check for deviations in the supply.
2 – Out-of-Specification
0x5111
(20753)
Warning
Primary supply voltage below minimum value
►
Check for deviations in the supply.
2 – Out-of-Specification
3
Overview of IO-Link Data and Functions (continued)
BOS R254K-UUI-LK10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LK10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LK10 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI LK10 S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 112: ......
Страница 113: ...BOS R254K UUI LK10 S4 Configuration Guide english...
Страница 114: ...www balluff com...