background image

 

 

www.balluff.com 

   

   

 

Getting Started 

3.2

 

Mechanical 
connection

 

  The module is attached using 2 M6 screws and 2 washers. Isolation pad as accessory 

available. 

 

3.3

 

Electrical 
connection 

   

 

 

Power Supply 

 

Power supply “IN” (7/8”, male) 

 

Pin 

Function 

Description 

GND actuator power supply 

0 V 

GND Bus- / Sensor power supply 

0 V 

Funktionserde 

FE 

Bus- / Sensor power supply 

+24 V, 9A DC 

Actuator power supply 

+24 V , 9A DC 

 

Power supply 

“OUT” (7/8” female) 

 

Pin 

Function 

Description 

GND actuator power supply 

0 V 

GND Bus- / Sensor power supply 

0 V 

Funktionserde 

FE 

Bus- / Sensor power supply 

+24 V, 9ADC 

Actuator power supply 

+24 V , 9A DC 

 

 

 

Note 

Provide sensor/bus power and actuator power from separate power sources if 
possible. 
Total current <9A. The total current of all modules may not exceed 9A even 
when daisy chaining the actuator supply. 

 

 

Grounding 

 

 

Note! 

The FE connection from the housing to the machine must be low-impedance 
and kept as short as possible. 

 

 

 

Profinet Interface 

 

Profinet (M12, D-Kodiert,female) 

 

Pin 

Funktion 

Belegung 

TD+  

gelb 

RD+  

weiß 

TD- 

orange 

RD- 

blau 

 

Note 

Connection of incoming Profinet cable at PN1. 
Connection of outgoing Profinet cable at PN2. 

 

Note! 

Unused I/O port socket must be fitted with cover caps to ensure IP67 protection 
rating. 

 

Содержание BNI PNT-502-001-Z002

Страница 1: ...BNI PNT 502 001 Z002 IP67 Modules Profinet IO Link Master User s Guide...

Страница 2: ...5 Profinet Interface 5 I O Port 6 IO Link Port 6 4 Technical data 7 4 1 Dimensions 7 4 2 Mechanical data 7 4 3 Electrical data 7 4 4 Operating conditions 7 4 5 Function indicators 8 Module LEDs 8 I O...

Страница 3: ...Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Procedures can also be shown...

Страница 4: ...take precautionary measures accordingly The device must be powered only using an approved power supply see chapter 4 Technical data Only approved cable may be used Operating and testing The operator...

Страница 5: ...rofinet Port2 3 Power supply IN 4 I O Port 1 5 I O Port 3 6 I O IO Link Port 5 7 I O IO Link Port 7 8 I O IO Link Port 6 9 I O IO Link Port 4 10 Symbol IO Link Port 11 I O Port 2 12 Port LED 13 E A Po...

Страница 6: ...y 0 V 3 Funktionserde FE 4 Bus Sensor power supply 24 V 9ADC 5 Actuator power supply 24 V 9A DC Note Provide sensor bus power and actuator power from separate power sources if possible Total current 9...

Страница 7: ...must be fitted with cover caps to ensure IP67 protection rating Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 IO Link Port IO Link Port M12 A coded female Pin Func...

Страница 8: ...Ports Connector M12 A coded 8x female Enclosure rating per IEC 60529 IP 67 only when plugged in and threaded in Weight 800 g 4 3 Electrical data Betriebsspannung 18 30 2 V DC per EN 61131 2 Restwellig...

Страница 9: ...f ProfiNet communication activ at Port PN2 ProfiNet communication not active at Port PN2 ERR Red Off Error module No error I O Port LEDs LED State Function 0 Off Yellow Red Input output signal at Pin...

Страница 10: ...example with the STEP 7 Engineering Tool 3 Including the module to Configuration 4 Setting the object properties 5 Naming of the device 6 Configuration of the Ethernet address 7 Integration to the Pro...

Страница 11: ...Balluff Network Interface Profinet BNI PNT 502 001 Z002 www balluff com 10 5 Integration 3 Naming of the device 4 Configuration of the Ethernet address...

Страница 12: ...ch das Einscannen werden alle angeschlossenen Profinet Teilnehmer erkannt und eine Auflistung erzeugt Module ohne Netzwerkadresse werden identifiziert eindeutig selektierbar ber die MAC Adresse Browse...

Страница 13: ...rk Interface Profinet BNI PNT 502 001 Z002 www balluff com 12 5 Integration 7 Integration by device name 8 Assumption of the properties MAC Address of the Module Assignment by Ip address Assignment by...

Страница 14: ...ork Interface Profinet Function 502 IP67 IO Module 4 x IO Link ports 4 x Standard I OPorts Variants 001 Standard Ausf hrung Mechanical version Z014 Die cast zinc housing Material 1 Balluff housing ver...

Страница 15: ...www balluff com 14 Notes...

Страница 16: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 869943 E Edition 1101 Subject to modification...

Отзывы: