background image

Balluff Network Interface Profinet, BNI PNT-502-001-Z002 

  www.balluff.com 

   

   

 

1

 

Notes to the User 

1.1

 

About this guide 

  The BNI PNT-502-

… serves as a decentralized IO Link Master module with standard I/O 

functions. 

This User’s Guide describes how to mount, integrate and use the BNI PNT-502. 

 

1.2

 

Structure of the 
guide

 

  The guide is organized so that the chapters build on one another. 

Chapter 2 

– Safety: Basic safety information. 

Chapter 3 

– Getting Started: The main steps for installing the device. 

Chapter 4 

– Technical Data: Technical data for the device 

Chapter 5 

– Integration: Integration into the plc 

Chapter 7- Appendix: Some frther Information about odering and included material. 

 

1.3

 

Typographical 
Conventions

 

  The following illustrations are used in this guide: 

 

 

Enumerations 

  Enumerations are shown in list form with bullets 

 

Entry 1, 

 

Entry 2. 

 

 

Actions 

  Action instructions are indicated by a preceding triangle. The result of an action is indicated 

by an arrow. 

 

Action instruction 1. 

 

Action result. 

 

Action instruction 2. 

Procedures can also be shown as numbers in brackets. 

(1)

 

Step no. 1 

(2)

 

Step no. 2 

 

 

Syntax 

  Numbers: 

 

Decimal numbers are shown without additional indicators (e.g. 123), 

 

Hexadecimal numbers are shown with the additional indicator hex (e.g. 00

hex

) or 

with the 

prefix “0x” (e.g. 0x00) 

 

 

Cross-references 

 

Cross references indicate where additional information on the topic can be found (see 
chapter 4 ”Technical Data”). 

 

1.4

 

Symbols 

 

Note tip 

This symbol indicates general notes. 

 
 

 

 Note 

This symbol indicates a security notice which most be observed. 

 

1.5

 

Abbreviations 

 

O-Port 
BNI 
EMC 
I-Port 
FE 
GSD-File  
LSB  
MSB 
SELV 
PLC 
PELV 

Digital Output Port 
Balluff Network Interface 
Elektromagnetic Compatibility 
Digital Input Port 
Function ground 
Generic Station Description 
Least Significant Bit 
Most Significant Bit 
Safety Extra Low Voltage 
Programmable Logic Controller 
Protective Extra Low Voltage 

 

Содержание BNI PNT-502-001-Z002

Страница 1: ...BNI PNT 502 001 Z002 IP67 Modules Profinet IO Link Master User s Guide...

Страница 2: ...5 Profinet Interface 5 I O Port 6 IO Link Port 6 4 Technical data 7 4 1 Dimensions 7 4 2 Mechanical data 7 4 3 Electrical data 7 4 4 Operating conditions 7 4 5 Function indicators 8 Module LEDs 8 I O...

Страница 3: ...Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Procedures can also be shown...

Страница 4: ...take precautionary measures accordingly The device must be powered only using an approved power supply see chapter 4 Technical data Only approved cable may be used Operating and testing The operator...

Страница 5: ...rofinet Port2 3 Power supply IN 4 I O Port 1 5 I O Port 3 6 I O IO Link Port 5 7 I O IO Link Port 7 8 I O IO Link Port 6 9 I O IO Link Port 4 10 Symbol IO Link Port 11 I O Port 2 12 Port LED 13 E A Po...

Страница 6: ...y 0 V 3 Funktionserde FE 4 Bus Sensor power supply 24 V 9ADC 5 Actuator power supply 24 V 9A DC Note Provide sensor bus power and actuator power from separate power sources if possible Total current 9...

Страница 7: ...must be fitted with cover caps to ensure IP67 protection rating Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 IO Link Port IO Link Port M12 A coded female Pin Func...

Страница 8: ...Ports Connector M12 A coded 8x female Enclosure rating per IEC 60529 IP 67 only when plugged in and threaded in Weight 800 g 4 3 Electrical data Betriebsspannung 18 30 2 V DC per EN 61131 2 Restwellig...

Страница 9: ...f ProfiNet communication activ at Port PN2 ProfiNet communication not active at Port PN2 ERR Red Off Error module No error I O Port LEDs LED State Function 0 Off Yellow Red Input output signal at Pin...

Страница 10: ...example with the STEP 7 Engineering Tool 3 Including the module to Configuration 4 Setting the object properties 5 Naming of the device 6 Configuration of the Ethernet address 7 Integration to the Pro...

Страница 11: ...Balluff Network Interface Profinet BNI PNT 502 001 Z002 www balluff com 10 5 Integration 3 Naming of the device 4 Configuration of the Ethernet address...

Страница 12: ...ch das Einscannen werden alle angeschlossenen Profinet Teilnehmer erkannt und eine Auflistung erzeugt Module ohne Netzwerkadresse werden identifiziert eindeutig selektierbar ber die MAC Adresse Browse...

Страница 13: ...rk Interface Profinet BNI PNT 502 001 Z002 www balluff com 12 5 Integration 7 Integration by device name 8 Assumption of the properties MAC Address of the Module Assignment by Ip address Assignment by...

Страница 14: ...ork Interface Profinet Function 502 IP67 IO Module 4 x IO Link ports 4 x Standard I OPorts Variants 001 Standard Ausf hrung Mechanical version Z014 Die cast zinc housing Material 1 Balluff housing ver...

Страница 15: ...www balluff com 14 Notes...

Страница 16: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 869943 E Edition 1101 Subject to modification...

Отзывы: