1.1.  About This 

Manual 

  This manual describes the Balluff IO-Link I/O module, also called a sensor/actuator hub. 

The IO-Link protocol is used to link to the higher-level master module. 
In terms of function, this compact, cost-effective module is similar to a passive splitter box; it 
records digital and analog sensor signals and transmits them over the IO-Link interface. It 
passes control signals coming over IO-Link to the connected actuators. 

 

1.2.  Structure of the 

Manual 

  The manual is organized so that the sections build on one another. 

Chapter 2: Basic Safety Information. 
…….. 

 

1.3.  Typographical 

Conventions 

 

The following typographical conventions are used in this manual. 

 

Enumerations 

  Enumerations are shown as a list with an dash. 

 

Entry 1

 

Entry 2.

 

 

Actions 

  Action instructions are indicated by a preceding triangle. The result of an action is indicated 

by an arrow. 

 

Action instruction 1. 

 

Action result. 

 

Action instruction 2. 

 

Syntax 

 

Numbers: 

Decimal numbers are shown without additional indicators (e.g. 123). 
Hexadecimal numbers are shown with the additional indicator 

hex

 (e.g. 00

hex

). 

 

Cross-references 

  Cross-references indicate where additional information on the topic can be found. 

 

1.4.  Symbols 

 

Attention! 

This symbol indicates a safety instruction that must be followed without exception 

 

 

 

Note 

This symbol indicates general notes. 

 

1.5.   Abbreviations 

  BNI 

DPP 
I/O port 
EMC  
FE  
IOL  
LSB 
MSB  
SPDU 

Balluff Network Interface 
Direct Parameter Page 
Digital input/output port 
Electromagnetic compatibility 
Function Earth 
IO-Link 
Least Significant Bit 
Most Significant Bit 
Service Protocol Data Unit 

 

1.6.  Differing views 

  Product views and images in this manual may differ from the product described. They are 

intended to serve only as illustrations. 

 

Содержание BNI IOL-309-002-Z019

Страница 1: ...BNI IOL 309 002 Z019 IO Link 1 1 sensor actuator hub with extension port User s Guide...

Страница 2: ...General Configuration 9 4 1 Extension port 9 Extension port configuration 55hex 9 Setting the serial number 54hex 9 5 Configuration Extension Off 10 5 1 IO Link Data 10 5 2 Process Data Input 10 5 3...

Страница 3: ...ion 22 8 4 Resetting to Factory Settings 22 9 Technical Data 23 9 1 Dimensions 23 9 2 Mechanical Data 23 9 3 Electrical Data 23 9 4 Operating conditions 23 10 Function Indicators 24 10 1 Function Indi...

Страница 4: ...with an dash Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2...

Страница 5: ...proper use Use installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class...

Страница 6: ...rview Figure 3 1 Connection overview BNI IOL 309 002 Z019 1 Ground connection 2 Mounting hole 3 Status LED communication 4 Label 5 Port 1 6 Port 3 7 Port 5 8 Port 7 extension port 9 Pin Port LED signa...

Страница 7: ...ound The modules are equipped with a ground connection Figure 3 3 BNI ground connection IOL 309 Connect the sensor hub module to the ground connection Note The functional ground connection from the ho...

Страница 8: ...port BNI IOL 309 002 Z019 IN OUT Sensor actuator interface Standardl input output port M8 Pin Function IN OUT 1 24V 4 In Out 3 0V Note For the digital inputs the input guideline specified in EN 61131...

Страница 9: ...L 309 002 Z019 0 BNI IOL 309 002 Z019 with BNI IOL 102 002 Z019 1 Note The Factory reset command does not affect the configuration of the extension port in any way Note The process data length depends...

Страница 10: ...1 byte output 5 2 Process Data Input Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port...

Страница 11: ...text 16 bytes sensor actuator hub M8 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Parameter Data Demand Data...

Страница 12: ...n Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port 0 Pin 4 Direction port x 0 Input 1 Output Safe state of Outputs 42hex The safe...

Страница 13: ...www balluff com 13 5 Configuration Extension Off Value Output state bin dec 00 0 Output is 0V 01 1 Output is 24V 10 2 Current status is maintained 11 3 Not defined...

Страница 14: ...Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1 Short circuit Port 1 Pin 1 Short circuit Port 0 Pin 1 Outputs off UA too low Undervoltage UA Undervoltage US Monitorin...

Страница 15: ...e input 1 byte output 6 2 Process Data Input Data Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin...

Страница 16: ...com 16 6 Configuration extended with BNI IOL 102 002 Z019 6 3 Process Data Output Data Byte 0 Bit 7 6 5 4 3 2 1 0 Description Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3...

Страница 17: ...BNI0099 14hex 0 Product text 16 bytes M12 sensor actuator hub 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Par...

Страница 18: ...0 Pin 4 Byte 1 Bit 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 20 19 18 17 Extension port Description Inversion Port 7 Pin 4 Inversion Port 6 Pin 4 Inversion Port 5 Pin 4 Inversion Port 4 Pin 4 Inversion Po...

Страница 19: ...each output adopts the configured status The following statuses can be configured for each pin Safe state of the outputs on Pin 4 42hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1...

Страница 20: ...28 27 26 25 Extension port Description Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Short circuit Port 5 Pin 1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin...

Страница 21: ...sion 1 0 Event code Description 0x5112 Low sensor voltage US 0x5114 Low actuator voltage UA 0x5410 Output stages 0x8DF0 Retry at the extension port 0x8DF1 Device lost at the extension port 0x8DF2 Wron...

Страница 22: ...iguration is automatically transferred to the new device This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of dat...

Страница 23: ...voltage 18 30 2 V DC corresponding to EN 61131 2 Ripple 1 Current consumption without load extension off 90 mA Load current PIN 1 max 200 mA temperature dependent Load current per output PIN 4 max 30...

Страница 24: ...ww balluff com 24 10 Function Indicators 10 1 Function Indicators LED Indicators module status LED Status Function COM US UA Green Communication error Green flashing Communication ok Red Undervoltage...

Страница 25: ...ircuit Off Input output signal 0 Extension port The table is valid if the extension port is active If the extension port is used as a standard I O then the description from Digital LED indicators for...

Страница 26: ...r code BNI IOL 309 002 Z019 BNI0093 BNI IOL 309 002 Z019 Balluff Network Interface IO Link interface Functions 309 8 inputs outputs Variants 002 with IO Link 1 1 extension port Mechanical configuratio...

Страница 27: ...www balluff com 27 Notes...

Страница 28: ...com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 926029 726 E Edition I18 Replaces Edition E16 Subject to m...

Отзывы: