background image

Balluff Network Interface / IO-Link  
 

 

 

www.balluff.com 

   

   

 

  39 

7

 

Configuration: BNI IOL-302-S02-Z012-C11 extended with 22/24 valve terminal 

Setting the 
serial number 
54

hex

 

  The serial number has a factory set value consisting of 16 ASCII characters, e.g. 0E-G550389-

1D-26. The serial number of the unit cannot be changed. For reasons of compatibility this 
parameter can be used to assign a custom serial number. 

 

Configuration 
of the 
extension 
port  
55

hex

 

 

Configuration 

Value of IDSU-Index 

55

hex

 

Device alone (extension port not active) 

Device with identical device 

Device with BNI IOL-751-V08-K007 

Device with BNI IOL-751-V10-K007 

Device with BNI IOL-751-V13-K007 

 

 

Содержание BNI IOL-302-S02-Z012-C11

Страница 1: ...BNI IOL 302 S02 Z012 C11 IO Link 1 1 Sensor Actuator Hub with Extension Port User s Guide...

Страница 2: ...cess data 11 Output process data 11 Configuration of the extension port 12 Data handling with extension port 13 5 Configuration Device alone extension port inactive 14 Device version 14 Configuration...

Страница 3: ...ut Data 32 Parameter data identification data and device parameters 33 Parameter data Device configuration 34 Inversion of the inputs 40hex 34 Safe state of the outputs 42hex 35 Safe state of the outp...

Страница 4: ...ns are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Syntax Numbers Decimal numbers are shown without addit...

Страница 5: ...rized tampering Improper use Use installation or handling contrary to the instructions provided in this User s Guide Obligations of the operating company This device meets the specifications for EMC C...

Страница 6: ...nting hole 2 Label 3 Communication status 4 Port 1 5 Port 3 6 Port 5 7 Port 7 extension port 8 Pin port LED signal status 9 Port 6 10 Port 4 11 Port 2 12 Port 0 13 IO Link interface 14 Additional powe...

Страница 7: ...ee different types of connection are used for supplying the module US1 the sensors US2 and the actuators UA The following connections are available depending on the device type BNI IOL 302 S02 Z012 C1...

Страница 8: ...n The IO Link connection is established via an M12 connector A coded male This connection is used for supplying the module For some devices this terminal is also used for powering the sensors and or a...

Страница 9: ...input guideline specified in EN 61131 2 Type 3 applies Note Unused input port sockets must be fitted with blind caps to ensure the IP67 degree of protection Extension port Port 7 M12 A coded female wh...

Страница 10: ...tension port These modules use port 7 in various ways By default it is used as a digital I O slot where both pin 2 and pin 4 can be used as a digital input or output This slot can be used as an extens...

Страница 11: ...of the incoming process data A detailed description can be found in the next sections Digital input status Diagnostics info Pin4 Pin2 Voltage monitoring Output port monitoring Short circuit Device ve...

Страница 12: ...V13 K007 The device connected to the extension port is referred to in the user s guide as the second device Note The command for resetting to factory defaults Factory reset has no effect on the config...

Страница 13: ...ata or ISDU are calculated as a unification of the process data or ISDU provided by both parties PD result PD of the first device PD of the second device ISDU result ISDU of the first device ISDU of t...

Страница 14: ...ation of the extension port The factory default is extension port inactive Configuration Value of IDSU Index 55hex 85 Device alone extension port not active 0 Device with identical device 1 Device wit...

Страница 15: ...rt 5 pin 4 Port 4 pin 4 Port 3 pin 4 Port 2 pin 4 Port 1 pin 4 Port 0 pin 4 Port 7 pin 2 Port 6 pin 2 Port 5 pin 2 Port 4 pin 2 Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Byte 2 3 Bit 7 6 5 4...

Страница 16: ...dentification data and device parameters DPP ISDU Parameter Data width Access rights Default Value Index Index Sub index Identification data 07hex Vendor ID 2 bytes Read only 0378hex 08hex 09hex Devic...

Страница 17: ...hex 44hex 68 0 1 16 Voltage monitoring 2 bytes Read 45hex 69 0 1 16 Output monitoring 2 bytes Read 54hex 84 0 Serial number 16 bytes Reading writing 16x00hex 55hex 85 0 Extension port 1 byte Reading w...

Страница 18: ...configured for each output pin Value Output status Safe State bin dec 00 0 Output is 0 V 01 1 Output is 24 V 10 2 Current status is maintained 11 3 Not defined Safe state of the outputs on pin 4 42he...

Страница 19: ...pin 2 Port 6 pin 2 Port 5 pin 2 Port 4 pin 2 Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Setting the serial number 54hex The serial number has a factory set value consisting of 16 ASCII charac...

Страница 20: ...xtension port Configuration Value of IDSU Index 55hex Device alone extension port not active 0 Device with identical device 1 Device with BNI IOL 751 V08 K007 2 Device with BNI IOL 751 V10 K007 3 Devi...

Страница 21: ...pin 2 Port 4 pin 2 Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Volt monitoring SC Port 7 Pin 1 SC Port 6 Pin 1 SC Port 5 Pin 1 SC Port 4 Pin 1 SC P...

Страница 22: ...pin 2 Port 1 pin 2 Port 0 pin 2 Byte 8 9 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Extension port Volt monitoring SC Port 7 Pin 1 SC Port 6 Pin 1 SC Port 5 Pin 1 SC Port 4 Pin 1 SC Port 3 Pin 1 SC Port 2 Pi...

Страница 23: ...rt 4 pin 4 Port 3 pin 4 Port 2 pin 4 Port 1 pin 4 Port 0 pin 4 Port 6 pin 2 Port 5 pin 2 Port 4 pin 2 Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 O...

Страница 24: ...nsor Hub Actuator Hub M12 extended with Sensor Hub Actuator Hub M12 15hex 21 0 Serial number 16 bytes 16hex 22 0 Hardware Revision 17hex 23 0 Firmware Revision 18hex 24 0 Application specific tag 32 b...

Страница 25: ...4 Port 2 pin 4 Port 1 pin 4 Port 0 pin 4 Port 6 pin 2 Port 5 pin 2 Port 4 pin 2 Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 2...

Страница 26: ...e configured status The following states can be configured for each output pin Value Output status Safe State bin dec 00 0 Output is 0 V 01 1 Output is 24 V 10 2 Current status is maintained 11 3 Not...

Страница 27: ...t 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1 8 7 6 5 Safe state of Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Port 6 pin 2 Port 5 pin 2 Port 4 pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5...

Страница 28: ...ort 4 Pin 1 SC Port 3 Pin 1 SC Port 2 Pin 1 SC Port 1 Pin 1 SC Port 0 Pin 1 Outputs off UA too low Undervoltage UA Undervoltage US1 Output monitoring 45hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0...

Страница 29: ...racters e g 0E G550389 1D 26 The serial number of the unit cannot be changed For reasons of compatibility this parameter can be used to assign a custom serial number Configuration of the extension por...

Страница 30: ...200 mA vs 2 A BNI IOL 302 S02 Z012 C11 with BNI IOL 751 V08 K007 BNI IOL 751 V10 K007 BNI IOL 751 V13 K007 Configuration of the extension port Configuration Value of IDSU Index 55hex Device alone exte...

Страница 31: ...5 pin 2 Port 4 pin 2 Port 3 pin 2 Port 2 pin 2 Port 1 pin 2 Port 0 pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Volt monitoring SC Port 7 Pin 1 SC Port 6 Pin 1 SC Port 5 Pin 1 SC Port 4 Pin 1 S...

Страница 32: ...13 K007 No function with BNI IOL 751 V13 K007 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Valve terminal on the extension port Output status of Valve 12 Coil A Valve 11 Coil A Valve 10 Coil A Valve 0...

Страница 33: ...s BALLUFF 11hex 17 0 Manufacturer text 15 bytes www balluff com 12hex 18 0 Product name BNI IOL 302 S02 Z012 C11 with BNI IOL 751 V08 K007 BNI IOL 751 V10 K007 BNI IOL 751 V13 K007 13hex 19 0 Product...

Страница 34: ...tate on Pin 2 2 bytes Reading writing 0hex 44hex 68 0 1 24 Volt monitoring 3 bytes Read 45hex 69 0 1 48 Output monitoring 6 bytes Read 54hex 84 0 Serial number 16 bytes Reading writing 0hex 55hex 85 0...

Страница 35: ...gured status The following states can be configured for each output pin Value Output status Safe State bin dec 00 0 Output is 0 V 01 1 Output is 24 V 10 2 Current status is maintained 11 3 Not defined...

Страница 36: ...oil A Valve 03 Coil A Valve 02 Coil A Valve 01 Coil A Byte 6 7 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 32 30 28 26 Valve terminal on the extension port Safe state of Valve 12 Coil B Valve 11 Coi...

Страница 37: ...2 Port 6 pin 2 Port 5 pin 2 Port 4 pin 2 Voltage monitoring 44hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 Volt monitoring SC Port 7 Pin 1 SC Port...

Страница 38: ...Sub index 39 37 35 33 31 29 27 25 23 21 19 17 Valve terminal on the extension port Short circuit on Valve 12 Coil A Valve 11 Coil A Valve 10 Coil A Valve 09 Coil A Valve 08 Coil A Valve 07 Coil A Valv...

Страница 39: ...haracters e g 0E G550389 1D 26 The serial number of the unit cannot be changed For reasons of compatibility this parameter can be used to assign a custom serial number Configuration of the extension p...

Страница 40: ...arily unavailable Events IO Link Revision 1 0 Event code Description 0x5112 Low sensor voltage US 0x5114 Low actuator voltage UA 0x5410 Output stages 0x8DF0 Repetition on extension port 0x8DF1 Device...

Страница 41: ...ce is replaced the parameters can be automatically transmitted to the new device This guarantees minimal downtimes Validation must be switched on in order to use data storage For information about the...

Страница 42: ...68 x 181 5 x 31 8 mm Electrical data Supply voltage 18 30 2 V DC per EN 61131 2 Power supply on M12 terminal 4 A Ripple 1 Current consumption without load 50 mA Load current Pin 1 max 200 mA Load curr...

Страница 43: ...Pin 4 LED 1 input output on Pin 2 Indicator Request Signal Yellow Input output signal 1 Red Sensor supply short circuit Actuator warning Actuator short circuit Off Input output signal 0 Extension port...

Страница 44: ...2 S02 Z012 C11 Balluff Network Interface IO Link interface Functions 302 16 PNP inputs outputs Variants S02 with IO Link 1 1 extension port and single channel monitoring Mechanical configuration Z012...

Страница 45: ...Balluff Network Interface IO Link www balluff com 45 Notes...

Страница 46: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 948752 E Edition H20 subject to modification...

Отзывы: