Balluff BNI IOL-302-000-Z026 Скачать руководство пользователя страница 3

Balluff Network Interface / IO-Link BNI IOL-302-xxx-Z026 

 

 

www.balluff.com 

2

1

 

Notes for the user 

1.1  About this guide 

  This  guide  describes  the  Balluff  Network  Interface  BNI  IOL-302-xxx-Z026  for  the  application  as 

peripheral in-/ output module to establish connection of binary standard sensors or actuators. Hereby 
it  is  about  an  IO-Link  device  which  communicates  by  means  of  IO-Link  protocol  with  the 
superordinate IO-Link master assembly. 

 

   

1.2  Structure of the 

guide 

  The guide is organized so that the sections build on one another: 

Section 2: Basic safety information. 
Section 3: The main steps for installing the device. 
Section 4: IO-Link, parameter and process data for the device.´ 
Section 5: Technical data for the device. 

 

   

1.3  Typographical 

conventions 

 

The following typographical conventions are used in this guide.

 

 

 

 

1.3.1 Enumerations 

 

Enumerations are shown in list form with bullet points: 

Entry 1, 

Entry 2. 

 

 

 

1.3.2 Actions 

 

Action instructions are indicated by a preceding triangle. The result of an action is indicated 
by an arrow. 

  Action instruction 1. 

  Action result. 

  Action instruction 2. 

 

 

 

1.3.3 Syntax 

 

Numbers: 

 

Decimal numbers are shown without additional indicators (e.g. 123), 

 

Hexadecimal numbers are shown with the additional indicator 

hex

 (e.g. 00

hex

).

 

 

1.3.4 Cross references 

  Cross references indicate where additional information on the topic can be found (see section 5 

„Technical data”).

 

 

1.4  Symbols 

 

Note, Tipp 

This symbol indicates general notes. 

 
 

 

Note! 

This symbol indicates a security notice which must be observed. 

 

1.5  Abbreviations 

  BNI        Balluff Network Interface 

I/O port  Standard input / output port 
DPP       Direct Parameter Page 
IOL         IO-Link 
EMC      Electromagnetic Compatibility 
FE         Function earth 
SPDU    Service Protocol Data Unit 

 

   

 
 
 
 

Содержание BNI IOL-302-000-Z026

Страница 1: ...BNI IOL 302 000 Z026 BNI IOL 302 S01 Z026 User s Guide...

Страница 2: ...gs 3 3 Getting started 3 1 Connection overview 4 3 2 Mechanical connection 5 3 3 Electrical connection 5 3 3 1 IO Link interface 5 3 3 2 Supply voltage connection 5 3 3 3 Sensor Actuator interface 6 4...

Страница 3: ...llowing typographical conventions are used in this guide 1 3 1 Enumerations Enumerations are shown in list form with bullet points Entry 1 Entry 2 1 3 2 Actions Action instructions are indicated by a...

Страница 4: ...nty The device complies with EMC Class A Such equipment may generate RF noise The operator must take precautionary measures accordingly The device must be powered only using an approved power supply s...

Страница 5: ...on 4 Status LED communication module 5 Standard I O port 1 6 Standard I O port 3 7 Standard I O port 5 8 Standard I O port 7 9 Mounting hole 10 Pin Port LED Signal status 11 Standard I O port 6 12 Sta...

Страница 6: ...tial 4 C Q IO Link data transmission channel 5 FE function earth Connecting the hub Connection protection ground to FE terminal if present Connect sensor actuator supply Connect the incoming IO Link l...

Страница 7: ...male interface Pin Function 1 24V 300mA 2 Input 2 Output 2 3 GND 4 Input 1 Output 1 5 FE Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 Note Outputs Maximum 2A per...

Страница 8: ...Input 7 0 Input 6 0 Input 5 0 Input 4 0 Input 3 0 Input 2 0 Input 1 0 Input 0 0 Input 7 1 Input 6 1 Input 5 1 Input 4 1 Input 3 1 Input 2 1 Input 1 1 input 0 1 BNI IOL 302 S01 Z026 Byte 0 Byte 1 7 6 5...

Страница 9: ...cuit Port 4 1 Short circuit Port 3 1 Short circuit Port 2 1 Short circuit Port 1 1 Short circuit Port 0 1 Note Actuator short circuit overload or short circuit of the output signal against 0V 4 3 Proc...

Страница 10: ...hub metal 0x16 0 Hardware Revision 1 Byte 0x17 0 Firmware Revision 23 Byte Parameter data 0x40 0 1 16 Inversion 2 Byte 0 FFFF 0x0000 0x42 0 1 8 Fault state Pin4 2 Byte 0 FFFF 0x0000 0x43 0 1 8 Fault...

Страница 11: ...r voltage UA Under voltage US2 Under voltage US1 Subindex 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Actuator short circuit Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Short circuit Port 7 0 Short circu...

Страница 12: ...ow voltage UA 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0004 0xF3 0x5114 Disappears Error AL Device Hardware Supply Supply low voltage UA 0x80 0x30 0x03 0x5000 0x0100 0x0010 0x0004 0xB3 0x5114 Appears Err...

Страница 13: ...I O ports M12 female 5 poles Enclosure rating per IEC 60529 IP 67 only when plugged in and threaded in Dimensions B x H x T in mm 68 x 181 5 x 32 4 Weight ca 500 gr 5 3 Electrical data Supply voltage...

Страница 14: ...tage LED 2 Green Red Supply actuators ok Under voltage LED 3 Green Red Supply sensors ok Under voltage LED 4 Green Green flashing Communication error Communication ok LED I O ports standard Indicator...

Страница 15: ...echanical design Z026 Die cast zinc housing matte nickel plated Bus connection and power supply 1xM12 male external thread Power supply 1x7 8 male external thread I O Ports 8xM12 female 5 poles intern...

Страница 16: ...IO Link BNI IOL 302 xxx Z026 www balluff com 15 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 884703 E Issue 11...

Отзывы: