IO-Link Sensor-Hub / Actuator Hub 

 

  www.balluff.com 

   

   

 

1

 

Notes to the user 

1.1

 

About this guide 

  This guide describes the Balluff IO-Link sensor collector module, also called the Sensor Hub 

/ Actor Hub. 
Connection to the host interface master is made through the IO-Link protocol. 
Functionally this compact, cost-effective module is comparable with a passive splitter box: It 
takes digital and analog sensor signals and passes them over the IO-Link interface. 

 

1.2

 

Structure of the 
guide

 

  The Guide is organized so that the sections build on one another. 

Section 2 : Basic safety information. 
Section 3 : The main steps for installing the device. 
Section 4: IO-Link, parameter and process data for the device. 
Section 5: Technical data for the device.. 

 

1.3

 

Typographical 
conventions

 

 

The following typographical conventions are used in this Guide. 

 

 

Enumerations 

  Enumerations are shown in list form with bullet points. 

 

Entry 1, 

 

Entry 2. 

 

 

Actions 

  Action instructions are indicated by a preceding triangle. The result of an action is indicated 

by an arrow. 

 

Action instruction 1. 

 

Action result. 

 

Action instruction 2. 

 

 

Syntax 

  Numbers: 

Decimal numbers are shown without additional indicators (e.g. 123), 
Hexadecimal numbers are shown with the additional indicator 

hex 

(e.g. 00

hex

). 

 
 

 

Cross-references 

  Cross-references indicate where additional information on the topic can be found (see 

Section 5 -

"Technical Data“). 

 
 
 

1.4

 

Symbols 

 

Note! 

This symbol indicates a security notice which most be observed. 

 
 

 

Note tip 

This symbol indicates general notes. 

 

1.5

 

 Abbreviations 

  BNI 

DPP  
I/O-Port 
EMC 
FE  
IOL  
LSB 
MSB  
SPDU 
  

Balluff Network Interface 
Direct Parameter Page 
Digital input/output port 
Electromagnetic Compatibility 
Function ground 
IO-Link 
Least Significant Bit 
Most Significant Bit 
Service Protocol Data Unit 
 

Содержание BNI IOL-302-000-K006

Страница 1: ...BNI IOL 302 000 K006 BNI IOL 302 000 K006 C01 BNI IOL 302 S01 K006 BNI IOL 302 S01 K006 C01 IO Link 1 1 Sensor Hub Actuator Hub User s Guide...

Страница 2: ...ction 5 Sensor Hub connection 6 Module versions 6 3 6 Digital Sensors 6 4 IO Link Interface 7 4 1 IO Link Data 7 4 2 Process data inputs 7 4 3 Processdata Output data 11 4 4 Parameter data On request...

Страница 3: ...typographical conventions are used in this Guide Enumerations Enumerations are shown in list form with bullet points Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle...

Страница 4: ...onary measures accordingly The device must be powered only using an approved power supply see Section 5 Technical Data Only approved cables may be used Operation and testing The operator is responsibl...

Страница 5: ...atus LED Digital I O Port 5 pin 2 6 Digital I O Port 5 7 Status LED Digital I O Port 5 pin 4 8 Digital I O Port 7 9 Status LED Power Supply 10 Digital I O Port 6 11 Digital I O Port 4 12 Digital I O P...

Страница 6: ...on ground The modules are provided with a ground terminal Connect Sensor Hub module to the ground terminal Note The FE connection from the housing to the machine must be low impedance and as short as...

Страница 7: ...channel monitoring BNI IOL 302 000 K006 C01 16 Inputs Outputs configurable with identification BNI IOL 302 S01 K006 C01 16 Inputs Outputs configurable with single channel monitoring and identificatio...

Страница 8: ...ess data length 4 byte input 2 byte output BNI IOL 302 S01 K006 C01 Baudrate COM2 38 4 kBaud Frame type 2 V Minimum cycle time 5 5 ms Process data length 10 byte input 2 byte output 4 2 Process data i...

Страница 9: ...g Undervoltage Ua Undervoltage Us Byte 4 5 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Short Circuit Port 7 Pin 4 Short Circuit Port 6 Pin 4 Short Circuit Port 5 Pin 4 Short Circuit Port 4 Pin 4 S...

Страница 10: ...6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 I...

Страница 11: ...7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Short Circuit Port 7 Pin 4 Short Circuit Port 6 Pin 4 Short Circuit Port 5 Pin 4 Short Circuit s Port 4 Pin 4 Short Circuit Port 3 Pin 4 Short Circuit Port...

Страница 12: ...est data DPP SPDU Parameter Data length Range Default value Index Index Sub index Identification Data 07hex Vendor ID 2 Byte Read only 0378hex 08hex 09hex Device ID 3 Byte 05010Bhex 302 000 K006 05010...

Страница 13: ...ly Monitoring 2 Byte 0hex FF0Dhex 45hex 69 0 1 16 Actuator short 2 Byte 0hex FFFFhex 46hex 70 0 1 16 Actuator warning 2 Byte 0hex FFFFhex 47hex 71 0 Us Ua warning 2 Byte 0hex 1hex 1hex 60hex 96 0 Iden...

Страница 14: ...Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 Description Direction Port 7 Pin 4 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Di...

Страница 15: ...1 8 7 6 5 Description Fault State Port 3 Pin 2 Fault State Port 2 Pin 2 Fault State Port 1 Pin 2 Fault State Port 0 Pin 2 Fault State Port 7 Pin 2 Fault State Port 6 Pin 2 Fault State Port 5 Pin 2 Fa...

Страница 16: ...t 7 1 Short Circuit Port 6 1 Short Circuit Port 5 1 Short Circuit Port 4 1 Short Circuit Port 3 1 Short Circuit Port 2 1 Short Circuit Port 1 1 Short Circuit Port 0 1 Short circuit at Signalport at Po...

Страница 17: ...33 Parameter length overrun 0x8034 Parameter length underrun 0x8035 Function not available 4 6 Events IO Link Revision 1 0 Event Code Description 0x5112 Low sensor voltage US 0x5114 Low actuator volta...

Страница 18: ...threaded in Weight 90 g Dimensions L W H excluding connector 115 50 30 8 mm 5 3 Electrical data Operating voltage 18 30 2 V DC per EN 61131 2 Ripple 1 Current draw without load 65 mA 5 4 Operating co...

Страница 19: ...en slowly flashing Short Circuit Sensor supply Green rapidly flashing Module power supply 18 V Off Module unpowered Ua LED Green Actuator power supply OK Green slowly flashing Actuator short circuit G...

Страница 20: ...BNI005U BNI IOL 302 S01 K006 C01 BNI005W BNI IOL 302 xxx K006 C01 Balluff Network Interface IO Link interface Functions 302 16 inputs Outputs Version 000 Standard version S01 Single channel monitorin...

Страница 21: ...IO Link Sensor Hub Actuator Hub www balluff com 20 Notes...

Страница 22: ...ff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 887780 E Edition 1209 Revised Edition 1208 Subject to modi...

Отзывы: