background image

  www.balluff.com

 

   

 

 

2

 

Safety 

2.1.

 

Intended use 

  The BNI IOL-

… acts as a decentralized input sensor module, which is connected to a 

higher-level IO-Link master module through an IO-Link interface. 

 

1.1

 

Installation and 
Startup 

 

 

Note 

Installation and startup must only be carried out by trained technical personnel. 
Qualified personnel are people who are familiar with installation and operation of 
the product and have the necessary qualifications for these tasks. Any damage 
resulting from unauthorized tampering or improper use voids the manufacturer's 
guarantee and warranty. The operator must ensure that appropriate safety and 
accident prevention regulations are observed. 

 

 

2.2.

 

General Safety 
Notes 

 

Commissioning and inspection 

Before commissioning, carefully read the user's guide. 
The system must not be used in applications in which the safety of persons is dependent 
upon proper functioning of the device. 

Authorized personnel 

Installation and startup must only be carried out by trained technical personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this user's 

guide 

Obligations of the operating company 

The device is a piece of equipment in accordance with EMC Class A. This device can 
produce RF noise. The operator must take appropriate precautionary measures. The device 
may only be used with an approved power supply. Use only approved cables. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 
Intended use is ensured only when the housing is fully installed. 

 

2.3.

 

Resistance to 
Aggressive 
Substances 

 

 

Note 

The BNI modules always have good chemical and oil resistance. When used in 
aggressive media (such as chemicals, oils, lubricants and coolants, each in a 
high concentration (i.e. too little water content)), the material must first be 
checked for resistance in the particular application. No defect claims may be 
asserted in the event of a failure or damage to the BNI modules caused by such 
aggressive media.

 

 

 

 

Dangerous 
voltage 

 

 

Note 

Before maintenance, disconnect the device from the power supply. 

 

 

 

 

 

Note 

In the interests of product improvement, Balluff GmbH reserves the right to 
change the technical data of the product and the content of this manual 
at any time without notice. 

 

 
 

Содержание BNI IOL-104-S02-R012

Страница 1: ...BNI IOL 104 S02 R012 IO Link 1 1 sensor hub with extension port User s Guide...

Страница 2: ...uration Extension Off 10 4 1 IO Link Data 10 4 2 Process Data Input Data 10 4 3 Parameter Data Demand Data 11 Parameter Data Demand Data 11 Inversion of the inputs 40hex 12 Voltage monitoring 44hex 12...

Страница 3: ...ctory Settings 27 8 Technical Data 28 8 1 Dimensions 28 8 2 Mechanical Data 28 8 3 Electrical Data 28 8 4 Operating conditions 28 9 Function Indicators 29 9 1 Function Indicators 29 LED indicator modu...

Страница 4: ...re used in this manual Enumerations Enumerations are shown as a list with an en dash Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indica...

Страница 5: ...roper use Use installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class A...

Страница 6: ...1 Connection overview BNI IOL 104 S02 R012 1 Mounting hole 2 Label 3 Status LED communication 4 Port 1 5 Port 3 6 Port 5 7 Port 7 extension port 8 Pin Port LED signal status 9 Port 6 10 Port 4 11 Port...

Страница 7: ...odules are equipped with a ground connection Figure 3 3 BNI ground connection IOL 104 xxx Connect the sensor hub module to the ground connection Note The functional ground connection from the housing...

Страница 8: ...puts Sensor interface Digital input port M12 A coded female Pin Function 1 24 V 2 Input 2 3 0 V GND 4 Input 1 5 FE Note For the digital inputs the input guideline specified in EN 61131 2 Type 3 applie...

Страница 9: ...Extension port configuration Configuration Index 0x55 value BNI IOL 104 S02 R012 0 BNI IOL 104 S02 R012 with BNI IOL 104 S02 R012 1 BNI IOL 104 S02 R012 with BNI IOL 751 V08 K007 2 BNI IOL 104 S02 R0...

Страница 10: ...Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin...

Страница 11: ...20 24 bytes BNI IOL 104 S02 R012 13hex 19 0 Product ID 7 bytes BNI0090 14hex 20 0 Product text 16 bytes Sensor Hub M12 15hex 21 0 Serial number 16 bytes 0hex 16hex 22 0 Hardware revision 17hex 23 0 Fi...

Страница 12: ...n of Port 0 Pin 4 Inversion of Port 7 Pin 2 Inversion of Port 6 Pin 2 Inversion of Port 5 Pin 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2...

Страница 13: ...ut Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4...

Страница 14: ...Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin...

Страница 15: ...S02 R012 with BNI IOL 104 S02 R012 13hex 19 0 Product ID 7 bytes BNI0090 with BNI0090 14hex 20 0 Product text 16 bytes Sensor hub M12 extended with Sensor hub M12 15hex 21 0 Serial number 16 bytes 0he...

Страница 16: ...2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port 0 Pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 24 23 22 21...

Страница 17: ...rvoltage US1 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25 Extension port Description Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Sho...

Страница 18: ...put Data Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 I...

Страница 19: ...Valve 10 Coil A Valve 09 Coil A Valve 08 Coil A Valve 07 Coil A Valve 06 Coil A Valve 05 Coil A Valve 04 Coil A Valve 03 Coil A Valve 02 Coil A Valve 01 Coil A No function for V013 Byte 2 3 Bit 7 6 5...

Страница 20: ...V13 K007 13hex 19 0 Product ID 7 bytes BNI0090 with BNI006N BNI006P BNI006R 14hex 20 0 Product text 16 bytes Sensor hub M12 extended with Valve plug CG25 24 2 5 Sensor hub M12 extended with Valve plug...

Страница 21: ...nversion of Port 6 Pin 4 Inversion of Port 5 Pin 4 Inversion of Port 4 Pin 4 Inversion of Port 3 Pin 4 Inversion of Port 2 Pin 4 Inversion of Port 1 Pin 4 Inversion of Port 0 Pin 4 Inversion of Port 7...

Страница 22: ...et by the master then each output adopts the configured status The following statuses can be configured for each pin Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 23 21 19 17 Valve terminal o...

Страница 23: ...11 Coil B Valve 10 Coil B Valve 09 Coil B No function for V013 Byte 6 7 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 16 14 12 10 8 6 4 2 Valve terminal on extension port Description Valve 08 Coil B V...

Страница 24: ...2 1 16 15 14 13 12 11 10 9 Description Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Short circuit Port 5 Pin 1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1...

Страница 25: ...oil A Valve 01 Coil A No function for V013 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 24 22 20 18 16 14 12 10 8 6 4 2 Extension port Description Valve 12 Coil B Valve 11 Coil B Valve 10 Co...

Страница 26: ...not available 0x8036 Function temporarily unavailable 6 6 Events IO Link Revision 1 0 Event code Description 0x5112 Low sensor voltage US 0x5114 Low actuator voltage UA 0x5410 Output stages 0x8DF0 Re...

Страница 27: ...ransferred to the new device This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of data storage and validation ple...

Страница 28: ...3 5 x 68 x 36 8 mm 8 3 Electrical Data Supply voltage 18 30 2 V DC corresponding to EN 61131 2 Ripple 1 Current consumption without load 40 mA Load current PIN 1 Max 200 mA temperature dependent Total...

Страница 29: ...cators LED indicator module status Indicator Function COM Green No communication Green negatively pulsed Communication OK US1 LED Green Sensor power supply is OK Red Undervoltage 18 V UA LED Green Act...

Страница 30: ...gnal 1 Red Sensor power supply short circuit Off Input output signal 0 Extension port The table is valid if the extension port is active If the extension port is used as a standard I O then the descri...

Страница 31: ...04 S02 R012 BNI0090 BNI IOL 104 S02 R012 Balluff Network Interface IO Link interface Functions 104 16 inputs Variants S02 with IO Link 1 1 extension port Mechanical configuration R012 Plastic housing...

Страница 32: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 926589 E Edition L15 Subject to modification...

Отзывы: