IO-Link functions 

8.1.

 

IO-Link 
Version 1.0 / 
1.1 

  This device can be operated with an IO-Link master according to IO-Link version 1.0 and 

version 1.1. Version-specific functions such as data storage (version 1.1) are  
only supported in combination with a suitable IO-Link master. 

 

8.2.

 

Data Storage 

  Each IO-Link master of IO-Link version 1.1 features data storage in which an image of the IO-

Link device configuration can be stored. When a device is replaced, the stored configuration is 
automatically transferred to the new device. This guarantees minimal downtime. Validation must 
be switched on in order to use the data storage. For information about the configuration of data 
storage and validation, please refer to the user's guide of the respective IO-Link master. 

 

8.3.

 

Block 
Configuration 

  The device supports block configuration. This allows all parameters in a data block to be 

consistently imported from a controller or a configuration tool into the device. 

 

8.4.

 

Resetting to 
Factory 
Settings 

  The factory settings on the device can be restored by running the "restore factory settings" 

system command. 
0x82 must be written to Index 2 Subindex 0 for the command. 
The extension port setting is not reset in this process. 

 

 

   

 
 
 
 
 

All manuals and user guides at all-guides.com

Содержание BNI IOL-104-002-Z046

Страница 1: ...BNI IOL 104 002 Z046 IO Link 1 1 Sensor hub with extension port User s Guide All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...ration 9 4 1 Extension port 9 Extension port configuration 9 Setting the serial number 54hex 9 5 Configuration Extension Off 10 5 1 IO Link data 10 5 2 Process Data Input Data 10 5 3 Parameter Data De...

Страница 3: ...4 Operating conditions 20 10 Function indicators 21 10 1 Function indicators 21 LED indicator module status 21 Digital LED indicators for inputs outputs 22 Extension port 22 11 Appendix 23 11 1 Type...

Страница 4: ...on 1 Action result Action instruction 2 Syntax Numbers Decimal numerals are shown without an additional indicator e g 123 Hexadecimal numerals are shown with the additional indicator hex e g 00hex Cro...

Страница 5: ...ling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class A This device can produce RF noise...

Страница 6: ...e 3 Status LED communication 4 Part label 5 Port 1 6 Port 3 7 Port 5 8 Port 7 9 Port 9 10 Port 11 11 Port 13 12 Port 15 extension port 13 Pin Port LED signal status 14 Port 14 15 Port 12 16 Port 10 17...

Страница 7: ...round The modules are equipped with a ground connection Figure 3 3 BNI ground connection IOL Connect the sensor hub module to the ground connection Note The FE connection from the housing to the machi...

Страница 8: ...Digital port BNI IOL 104 002 Z046 IN Sensor interface Port Pin Function IN 1 24V 4 In 3 0V Note For the digital inputs the input guideline specified in EN 61131 2 Type 3 applies Note Unused input por...

Страница 9: ...h BNI IOL 104 002 Z046 1 Note The Factory reset command does not affect the configuration of the extension port in any way Note The process data length depends on the configuration The extension port...

Страница 10: ...nput 5 2 Process Data Input Data Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pi...

Страница 11: ...Product ID BNI00AY 14hex 0 Product text Sensor hub M8 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Parameter D...

Страница 12: ...of Port 10 Pin 4 Inversion of Port 9 Pin 4 Inversion of Port 8 Pin 4 Inversion of port x 0 Normal 1 Inverted Voltage monitoring 44hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 8 7 6 5 4...

Страница 13: ...ut Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 14 Pin 4 Input Port 13 Pin 4 Input Port 12 Pin 4 Input Port 11 Pin 4 Input Port 10 Pin 4 Input Port 9 Pin 4 Input Port 8 Pin 4 Byte 2 3...

Страница 14: ...002 Z046 with BNI IOL 104 002 Z046 13hex 0 Product ID BNI00AY with BNI00AY 14hex 0 Product text Sensor Hub M8 with Sensor Hub M8 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0...

Страница 15: ...Inversion of Port 10 Pin 4 Inversion of Port 9 Pin 4 Inversion of Port 8 Pin 4 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25 Extension port De...

Страница 16: ...rt 11 Pin 1 Short circuit Port 10 Pin 1 Short circuit Port 9 Pin 1 Short circuit Port 8 Pin 1 Byte 2 Bit 7 6 5 4 3 2 1 0 Sub Index 17 Description Undervoltage US Byte 3 4 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3...

Страница 17: ...rt Description Undervoltage US Setting the serial number 54hex The serial number has a default value of 16x00hex In order to use the Identity master validation mode a serial number can be set using th...

Страница 18: ...ink Revision 1 0 Event Code Description 0x5112 Low sensor voltage US 0x5114 Low actor voltage UA 0x5410 Output Stages 0x8DF0 Retry at the extension port 0x8DF1 Device lost at the extension port 0x8DF2...

Страница 19: ...evice This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of data storage and validation please refer to the user s...

Страница 20: ...ding to EN 61131 2 Ripple 1 Current consumption without load extension off 90 mA Load current PIN 1 Max 200 mA temperature dependent Total current US 3 5 A Inputs PNP type 3 9 4 Operating conditions O...

Страница 21: ...ndicators LED indicator module status LED Status Function COM US Green Communication error US OK Green flashing Communication OK and US OK Red flashing quickly Undervoltage module COM US All manuals a...

Страница 22: ...Extension port The table is valid if the extension port is active If the extension port is used as a standard I then the description from Digital LED indicators for inputs can be used Status Function...

Страница 23: ...I00AY BNI IOL 104 002 Z046 Balluff Network Interface IO Link interface Functions 104 16 inputs Variants 002 with IO Link 1 1 extension port Mechanical configuration Z046 Die cast zinc matte nickel pla...

Страница 24: ...ff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 931934 E Edition J16 Subject to change without notice All manuals and user...

Отзывы: