Configuration: extended with BNI IOL-102-002-Z019 

Safe state of 
Outputs 42

hex

 

  The safe state parameter makes it possible to configure the outputs in case of a fault. If no IO-

Link communication is possible or the "valid flag" of the output process data has not been set 
by the master, then each output adopts the configured status. The following statuses can be 
configured for each pin. 

 

Safe state of 
the outputs on 
Pin 4 42

hex

 

 

 

Byte 

Bit 

Sub- 

index 

Descr

ip

tio

n

 

S

afe s

tate P

or

t 3

 P

in 4

 

S

afe s

tate P

or

t 2

 P

in 4

 

S

afe s

tate P

or

t 1

 P

in 4

 

S

afe s

tate 

P

or

t 0

 P

in 4

 

S

afe s

tate P

or

t 6

 P

in 4

 

S

afe s

tate P

or

t 5

 P

in 4

 

S

afe s

tate P

or

t 4

 P

in 4

 

 

 

 

 

Value 

Output state 

bin 

dec 

00 

Output is 0V 

01 

Output is 24V 

10 

Current status is maintained 

11 

Not permitted 

 

 

Содержание BNI IOL-102-002-Z019

Страница 1: ...BNI IOL 309 002 Z019 IO Link 1 1 sensor actuator hub with extension port User s Guide ...

Страница 2: ...4 General Configuration 9 4 1 Extension port 9 Extension port configuration 55hex 9 Setting the serial number 54hex 9 5 Configuration Extension Off 10 5 1 IO Link Data 10 5 2 Process Data Input 10 5 3 Process Data Ouput 10 5 4 Parameter Data Demand Data 11 Parameter Data Demand Data 11 Inversion of the inputs 40hex 12 Configuration In Outputs 41hex 12 Safe state of Outputs 42hex 12 Voltage monitor...

Страница 3: ...tion 22 8 4 Resetting to Factory Settings 22 9 Technical Data 23 9 1 Dimensions 23 9 2 Mechanical Data 23 9 3 Electrical Data 23 9 4 Operating conditions 23 10 Function Indicators 24 10 1 Function Indicators 24 LED Indicators module status 24 Digital LED indicators for inputs outputs 25 Extension port 25 11 Appendix 26 11 1 Type Code 26 11 2 Ordering Information 26 ...

Страница 4: ... with an dash Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross references Cross references indicate whe...

Страница 5: ...mproper use Use installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class A This device can produce RF noise The operator must take appropriate precautionary measures The device may only be used with an approved power supply Use only approved cables Malfunctions In the eve...

Страница 6: ...erview Figure 3 1 Connection overview BNI IOL 309 002 Z019 1 Ground connection 2 Mounting hole 3 Status LED communication 4 Label 5 Port 1 6 Port 3 7 Port 5 8 Port 7 extension port 9 Pin Port LED signal status 10 Port 6 11 Port 4 12 Port 2 13 Port 0 14 IO Link interface 1 2 3 4 5 6 7 8 2 9 10 11 12 13 14 ...

Страница 7: ...round The modules are equipped with a ground connection Figure 3 3 BNI ground connection IOL 309 Connect the sensor hub module to the ground connection Note The functional ground connection from the housing to the machine must have low impedance and be kept as short as possible IO Link connection The IO Link connection is established via an M12 connector A coded male IO Link M12 A coded male Pin F...

Страница 8: ... port BNI IOL 309 002 Z019 IN OUT Sensor actuator interface Standardl input output port M8 Pin Function IN OUT 1 24V 4 In Out 3 0V Note For the digital inputs the input guideline specified in EN 61131 2 Type 3 applies Note Unused input port sockets must be fitted with blind caps to ensure the IP67 degree of protection Extension port Extension port M8 female The port acts like a sensor actuator int...

Страница 9: ...OL 309 002 Z019 0 BNI IOL 309 002 Z019 with BNI IOL 102 002 Z019 1 Note The Factory reset command does not affect the configuration of the extension port in any way Note The process data length depends on the configuration The extension port can be configured using parameter 0x55 table If data storage or validation is used validation identical must be used for configuring Depending on the system t...

Страница 10: ... 1 byte output 5 2 Process Data Input Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 5 3 Process Data Ouput Byte 0 Bit 7 6 5 4 3 2 1 0 Description Output Port 7 Pin 4 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Po...

Страница 11: ...t text 16 bytes sensor actuator hub M8 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Parameter Data Demand Data DPP SPDU Parameter Data width Access rights Default Value Index Index Subindex Parameter data 40hex 64 0 1 8 Inversion of the inputs 1 byte Read write 0hex 41hex 65 0 1 8 Config In Output 1 byte Read...

Страница 12: ...on Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port 0 Pin 4 Direction port x 0 Input 1 Output Safe state of Outputs 42hex The safe state parameter makes it possible to configure the outputs in case of a fault If no IO Link communication is possible or the valid flag of the output process data has not been set by the master then...

Страница 13: ...www balluff com 13 5 Configuration Extension Off Value Output state bin dec 00 0 Output is 0V 01 1 Output is 24V 10 2 Current status is maintained 11 3 Not defined ...

Страница 14: ...1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1 Short circuit Port 1 Pin 1 Short circuit Port 0 Pin 1 Outputs off UA too low Undervoltage UA Undervoltage US Monitoring the outputs 45hex Byte 0 Bit 7 6 5 4 3 2 1 0 Sub index 8 7 6 5 4 3 2 1 Description Short circuit Port 7 Pin 4 Short circuit Port 6 Pin 4 Short circuit Port 5 Pin 4 Short circuit Port 4 Pin 4 Short ...

Страница 15: ...te input 1 byte output 6 2 Process Data Input Data Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Byte 1 Bit 7 6 5 4 3 2 1 0 Extension port Description Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Por...

Страница 16: ...f com 16 6 Configuration extended with BNI IOL 102 002 Z019 6 3 Process Data Output Data Byte 0 Bit 7 6 5 4 3 2 1 0 Description Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output Port 0 Pin 4 ...

Страница 17: ... BNI0099 14hex 0 Product text 16 bytes M12 sensor actuator hub 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex Parameter Data Demand Data DPP SPDU Parameter Data width Access rights Default Value Index Index Sub index Parameter data 40hex 64 0 1 16 Inversion of the inputs 2 bytes Read write 0hex 41hex 65 0 1 16 ...

Страница 18: ... 0 Pin 4 Byte 1 Bit 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 20 19 18 17 Extension port Description Inversion Port 7 Pin 4 Inversion Port 6 Pin 4 Inversion Port 5 Pin 4 Inversion Port 4 Pin 4 Inversion Port 3 Pin 4 Inversion Port 2 Pin 4 Inversion Port 1 Pin 4 Inversion Port 0 Pin 4 Inversion port x 0 Normal 1 Inverted Configuration In Output 41hex Byte 0 Bit 7 6 5 4 3 2 1 0 Sub Index 8 7 6 5 4 3 2 1...

Страница 19: ...n each output adopts the configured status The following statuses can be configured for each pin Safe state of the outputs on Pin 4 42hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1 8 7 6 5 Description Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port 0 Pin 4 Safe state Port 6 Pin 4 Safe state Port 5 Pin 4 Safe state Port 4 Pin 4 Value Outpu...

Страница 20: ...9 28 27 26 25 Extension port Description Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Short circuit Port 5 Pin 1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1 Short circuit Port 1 Pin 1 Short circuit Port 0 Pin 1 Undervoltage UA Undervoltage US Monitoring the outputs 45hex Byte 0 Bit 7 6 5 4 3 2 1 0 Sub index 8 7 6 5 4 3 2 1 Description Short circuit Por...

Страница 21: ...ision 1 0 Event code Description 0x5112 Low sensor voltage US 0x5114 Low actuator voltage UA 0x5410 Output stages 0x8DF0 Retry at the extension port 0x8DF1 Device lost at the extension port 0x8DF2 Wrong device at the extension port IO Link Revision 1 1 Event code Description 0x5111 Low sensor voltage US 0x5112 Low actuator voltage UA 0x7710 Short circuit 0x8DF0 Retry at the extension port 0x8DF1 D...

Страница 22: ...figuration is automatically transferred to the new device This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of data storage and validation please refer to the user s guide of the respective IO Link master 8 3 Block Configuration The device supports block configuration This allows all parameters in a data block t...

Страница 23: ...y voltage 18 30 2 V DC corresponding to EN 61131 2 Ripple 1 Current consumption without load extension off 90 mA Load current PIN 1 max 200 mA temperature dependent Load current per output PIN 4 max 300 mA temperature dependent Inputs PNP type 3 9 4 Operating conditions Ambient temperature 5 C 70 C Storage temperature 25 C 70 C Degree of protection IP67 only in plugged in and screwed state ...

Страница 24: ...www balluff com 24 10 Function Indicators 10 1 Function Indicators LED Indicators module status LED Status Function COM US UA Green Communication error Green flashing Communication ok Red Undervoltage actuator Red fast flashing Undervoltage module COM US UA ...

Страница 25: ...circuit Off Input output signal 0 Extension port The table is valid if the extension port is active If the extension port is used as a standard I O then the description from Digital LED indicators for inputs outputs can be used Status Function Green IO Link connection active Green flashing No IO Link connection or faulty IO Link device Red flashing Incorrect IO Link device or incorrect configurati...

Страница 26: ...er code BNI IOL 309 002 Z019 BNI0093 BNI IOL 309 002 Z019 Balluff Network Interface IO Link interface Functions 309 8 inputs outputs Variants 002 with IO Link 1 1 extension port Mechanical configuration Z019 Die cast zinc housing matte nickel plated Bus connection and power supply 1x M12x1 external thread I O ports 8 x M8x1 internal thread ...

Страница 27: ...www balluff com 27 Notes ...

Страница 28: ...f com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 926029 726 E Edition I18 Replaces Edition E16 Subject to modification ...

Отзывы: