Balluff Network Interface EtherNet/IP
™
www.balluff.com
10
4
Technical data
4.1.
Dimensions
4.2.
Mechanical data
Housing material
Die case zinc, matt nickel plated
Enclosure rating per IEC 60529
IP 67 (only when plugged-in and threaded-in)
Supply voltage
7/8” 4-pin male
Input ports / Output ports
M12, A-coded (8 x female)
Dimensions (W x H x D in mm)
68 x 334 x 32.4
Mounting type
2-hole screw mount
Ground strap attachment
M4
Weight
Approx. 900 g
4.3.
Operating
conditions
Operating temperature T
a
Storage temperature
-5 °C ... 55 °C
-25 C ... 75 °C
EMC
- EN 61000-4-2/3/4/5/6
- EN 55011
- Severity level 4A/3A/4B/2A/3A
- Gr.1, CL. A
Shock/vibration
EN 60068-2-6, EN 60068-2-27
EN 60068-2-29, EN 60068-2-64
4.4.
Electrical data
Supply voltage
18...30.2 V DC, per EN 61131-2
Ripple
<1%
Input current at 24 V